OBJECT = COLUMN COLUMN_NUMBER = 1 NAME = CHECKSUM DATA_TYPE = ASCII_INTEGER START_BYTE = 2 BYTES = 11 DESCRIPTION = "Signed 32-bit Checksum of remaining 71 COLUMNs (189 ITEMS) of KEEPALIVE data, in binary format, for this row. N.B. this value may be negative. This CIDA_KEEPALIVE.FMT auxiliary label (^STRUCTURE) file comprises 72 COLUMNs (COLUMN_NAMEs ORIGINATOR through SPARE) and 190 ITEMS. N.B. some of the COLUMNs comprise multiple ITEMS. All of these values are numeric (ASCII_INTEGER or ASCII_REAL). In each row, each numeric value described by the 189 items after this CHECKSUM COLUMN can be represented as a signed 32-bit quantity. Summing those 189 signed 32-bit values, and discarding any overflow or underflow, will result in the 32-bit value described by this COLUMN. Conversion of a COLUMN value of DATA_TYPE = ASCII_INTEGER is straightforward. E.g. in Python with the Numpy module: import numpy I32 = numpy.int32( ItemString ) Conversion of a COLUMN value of DATA_TYPE = ASCII_REAL requires converting the ASCII REAL value to a 32-bit (4-byte) IEEE-754 floating-point values and then treating those 32-bits as an unsigned integer. The bits assignments for 4-byte IEEE-754 floating point values are described in the PDS Standards Reference. E.g. in Python: NPI32 = numpy.int32 F32 = numpy.float32( ItemString ) S32 = F32.tostring() I32 = numpy.fromstring( Str32, dtype=NPI32)[0] The byte order of the signed 32-bit integers and the 4-byte IEEE-754 floating point values is not important as long as it is consistent for the CHECKSUM. Obviously, the conversion of ASCII_REAL strings with 4-5 significant decimal digits to full 32-bit floating-point precision is suspect and may be architecture-dependent, but the procedure described above, executed on a 64-bit Intel-compatible system running Gnu/Linux, was found to correctly predict this CHECKSUM value for all sixty rows of keepalive data from the Stardust-NExT mission. " FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 2 NAME = ORIGINATOR DATA_TYPE = ASCII_INTEGER START_BYTE = 14 BYTES = 11 DESCRIPTION = "Software version initializing the keepalive data: 0 = unknown 1 = version 5, i.e. PROM 2 = version higher 8 or higher 3 = version 5 updated from higher version" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 3 NAME = USEHV DATA_TYPE = ASCII_INTEGER START_BYTE = 26 BYTES = 11 DESCRIPTION = "flag, if it is 0x48564F4 = 1213615947, let's the high voltages to be turn on automatically in boot" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 4 NAME = PARTITION DATA_TYPE = ASCII_INTEGER START_BYTE = 38 BYTES = 11 DESCRIPTION = "S/C memory partition used" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 5 NAME = MINUS_PARTITION DATA_TYPE = ASCII_INTEGER START_BYTE = 50 BYTES = 11 DESCRIPTION = "S/C memory partition used, negated" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 6 NAME = PRIM_PROTECTION DATA_TYPE = ASCII_INTEGER START_BYTE = 62 BYTES = 11 DESCRIPTION = "Primary FDAQ board protection flag, 0 = off, 1 = on" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 7 NAME = PRIM_AUTOCAL DATA_TYPE = ASCII_INTEGER START_BYTE = 74 BYTES = 11 DESCRIPTION = "Primary FDAQ board auto-calibration flag, 0 = off, 1 = on" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 8 NAME = PRIM_TARGET DATA_TYPE = ASCII_INTEGER START_BYTE = 86 BYTES = 11 DESCRIPTION = "Primary FDAQ board target flag, 0 = off, 1 = on" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 9 NAME = PRIM_LO DATA_TYPE = ASCII_INTEGER START_BYTE = 98 BYTES = 11 DESCRIPTION = "Primary FDAQ board low sensitivity channel, 0 = low sensitivity 1, 1 = low sensitivity 2" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 10 NAME = PRIM_HI DATA_TYPE = ASCII_INTEGER START_BYTE = 110 BYTES = 11 DESCRIPTION = "Primary FDAQ board high sensitivity channel, 0 = high sensitivity 1, 1 = high sensitivity 2" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 11 NAME = PRIM_PULSE DATA_TYPE = ASCII_INTEGER START_BYTE = 122 BYTES = 11 DESCRIPTION = "Primary FDAQ pulse trigger DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 12 NAME = PRIM_INTEGRAL DATA_TYPE = ASCII_INTEGER START_BYTE = 134 BYTES = 11 DESCRIPTION = "Primary FDAQ integral trigger DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 13 NAME = PRIM_LO_1 DATA_TYPE = ASCII_INTEGER START_BYTE = 146 BYTES = 11 DESCRIPTION = "Primary FDAQ low sensitivity 1 straight channel baseline DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 14 NAME = PRIM_LO_DELAY_1 DATA_TYPE = ASCII_INTEGER START_BYTE = 158 BYTES = 11 DESCRIPTION = "Primary FDAQ low sensitivity 1 delayed channel baseline DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 15 NAME = PRIM_HI_1 DATA_TYPE = ASCII_INTEGER START_BYTE = 170 BYTES = 11 DESCRIPTION = "Primary FDAQ high sensitivity 1 straight channel baseline DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 16 NAME = PRIM_HI_DELAY_1 DATA_TYPE = ASCII_INTEGER START_BYTE = 182 BYTES = 11 DESCRIPTION = "Primary FDAQ high sensitivity 1 delayed channel baseline DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 17 NAME = PRIM_LO_2 DATA_TYPE = ASCII_INTEGER START_BYTE = 194 BYTES = 11 DESCRIPTION = "Primary FDAQ low sensitivity 2 straight channel baseline DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 18 NAME = PRIM_LO_DELAY_2 DATA_TYPE = ASCII_INTEGER START_BYTE = 206 BYTES = 11 DESCRIPTION = "Primary FDAQ low sensitivity 2 delayed channel baseline DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 19 NAME = PRIM_HI_2 DATA_TYPE = ASCII_INTEGER START_BYTE = 218 BYTES = 11 DESCRIPTION = "Primary FDAQ high sensitivity 2 straight channel baseline DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 20 NAME = PRIM_HI_DELAY_2 DATA_TYPE = ASCII_INTEGER START_BYTE = 230 BYTES = 11 DESCRIPTION = "Primary FDAQ high sensitivity 2 delayed channel baseline DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 21 NAME = AUX_PROTECTION DATA_TYPE = ASCII_INTEGER START_BYTE = 242 BYTES = 11 DESCRIPTION = "Auxiliary FDAQ board protection flag, 0 = off, 1 = on" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 22 NAME = AUX_AUTOCAL DATA_TYPE = ASCII_INTEGER START_BYTE = 254 BYTES = 11 DESCRIPTION = "Auxiliary FDAQ board auto-calibration flag, 0 = off, 1 = on" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 23 NAME = AUX_TARGET DATA_TYPE = ASCII_INTEGER START_BYTE = 266 BYTES = 11 DESCRIPTION = "Primary FDAQ board target flag, 0 = off, 1 = on" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 24 NAME = AUX_LO DATA_TYPE = ASCII_INTEGER START_BYTE = 278 BYTES = 11 DESCRIPTION = "Auxiliary FDAQ board low sensitivity channel, 0 = low sensitivity 1, 1 = low sensitivity 2" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 25 NAME = AUX_HI DATA_TYPE = ASCII_INTEGER START_BYTE = 290 BYTES = 11 DESCRIPTION = "Auxiliary FDAQ board high sensitivity channel, 0 = high sensitivity 1, 1 = high sensitivity 2" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 26 NAME = AUX_PULSE DATA_TYPE = ASCII_INTEGER START_BYTE = 302 BYTES = 11 DESCRIPTION = "Auxiliary FDAQ pulse trigger DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 27 NAME = AUX_INTEGRAL DATA_TYPE = ASCII_INTEGER START_BYTE = 314 BYTES = 11 DESCRIPTION = "Auxiliary FDAQ integral trigger DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 28 NAME = AUX_LO_1 DATA_TYPE = ASCII_INTEGER START_BYTE = 326 BYTES = 11 DESCRIPTION = "Auxiliary FDAQ low sensitivity 1 straight channel baseline DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 29 NAME = AUX_LO_DELAY_1 DATA_TYPE = ASCII_INTEGER START_BYTE = 338 BYTES = 11 DESCRIPTION = "Auxiliary FDAQ low sensitivity 1 delayed channel baseline DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 30 NAME = AUX_HI_1 DATA_TYPE = ASCII_INTEGER START_BYTE = 350 BYTES = 11 DESCRIPTION = "Auxiliary FDAQ high sensitivity 1 straight channel baseline DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 31 NAME = AUX_HI_DELAY_1 DATA_TYPE = ASCII_INTEGER START_BYTE = 362 BYTES = 11 DESCRIPTION = "Auxiliary FDAQ high sensitivity 1 delayed channel baseline DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 32 NAME = AUX_LO_2 DATA_TYPE = ASCII_INTEGER START_BYTE = 374 BYTES = 11 DESCRIPTION = "Auxiliary FDAQ low sensitivity 2 straight channel baseline DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 33 NAME = AUX_LO_DELAY_2 DATA_TYPE = ASCII_INTEGER START_BYTE = 386 BYTES = 11 DESCRIPTION = "Auxiliary FDAQ low sensitivity 2 delayed channel baseline DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 34 NAME = AUX_HI_2 DATA_TYPE = ASCII_INTEGER START_BYTE = 398 BYTES = 11 DESCRIPTION = "Auxiliary FDAQ high sensitivity 2 straight channel baseline DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 35 NAME = AUX_HI_DELAY_2 DATA_TYPE = ASCII_INTEGER START_BYTE = 410 BYTES = 11 DESCRIPTION = "Auxiliary FDAQ high sensitivity 2 delayed channel baseline DA-converter setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 36 NAME = ACTIVE_FDAQ DATA_TYPE = ASCII_INTEGER START_BYTE = 422 BYTES = 11 DESCRIPTION = "Active FDAQ board 0 = primary, 1 = auxiliary" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 37 NAME = MM1 DATA_TYPE = ASCII_INTEGER START_BYTE = 434 BYTES = 11 DESCRIPTION = "MM-1 voltage setup value" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 38 NAME = POLARITY DATA_TYPE = ASCII_INTEGER START_BYTE = 446 BYTES = 11 DESCRIPTION = "Ion polarity, 1 = positive, 2 = negative" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 39 NAME = TARGET DATA_TYPE = ASCII_INTEGER START_BYTE = 458 BYTES = 11 DESCRIPTION = "Target size, 4 = small, 8 = large" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 40 NAME = HVS DATA_TYPE = ASCII_INTEGER START_BYTE = 470 BYTES = 11 DESCRIPTION = "High voltage setup, 0x00 = all off, 0x01 = converter on, 0x40 = RFB enabled, 0x80 = MM1-1 enabled, plus the OR-ed combinations of all bits" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 41 NAME = EDF_TIMEOUT DATA_TYPE = ASCII_INTEGER START_BYTE = 482 BYTES = 11 DESCRIPTION = "Time-out to send housekeeping data in milliseconds" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 42 NAME = COMPRESS DATA_TYPE = ASCII_INTEGER START_BYTE = 494 BYTES = 11 DESCRIPTION = "Channel Compression, 0 = off, 1 = Rice, 2 = wavelet" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 43 NAME = CHANNELS DATA_TYPE = ASCII_INTEGER START_BYTE = 506 BYTES = 11 DESCRIPTION = "Channels included in the EDF, 0x01 = low straight channel, 0x02 = low delayed channel, 0x04 = high straight channel, 0x08 = high delayed channel, plus the OR-ed combinations of all bits" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 44 NAME = ENCOUNTER DATA_TYPE = ASCII_INTEGER START_BYTE = 518 BYTES = 11 DESCRIPTION = "Encounter clock received from S/C" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 45 NAME = MINUS_ENCOUNTER DATA_TYPE = ASCII_INTEGER START_BYTE = 530 BYTES = 11 DESCRIPTION = "Encounter clock received from S/C negated" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 46 NAME = ENCOUNTER_LIMIT DATA_TYPE = ASCII_INTEGER START_BYTE = 542 BYTES = 203 ITEMS = 17 ITEM_BYTES = 11 ITEM_OFFSET = 12 DESCRIPTION = "Partition table limits expressed in encounter clock units" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 47 NAME = ENCOUNTER_FIRST_NEGATIVE DATA_TYPE = ASCII_INTEGER START_BYTE = 746 BYTES = 11 DESCRIPTION = "First time the instrument will switch the negative mode, in encounter clock units" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 48 NAME = ENCOUNTER_NEGATIVE_TIME DATA_TYPE = ASCII_INTEGER START_BYTE = 758 BYTES = 11 DESCRIPTION = "Time to stay in negative mode, in encounter clock units" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 49 NAME = ENCOUNTER_POSITIVE_TIME DATA_TYPE = ASCII_INTEGER START_BYTE = 770 BYTES = 11 DESCRIPTION = "Time to stay in positive mode, in encounter clock units" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 50 NAME = SWITCH_ONS DATA_TYPE = ASCII_INTEGER START_BYTE = 782 BYTES = 11 DESCRIPTION = "Number of instrument switch ons" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 51 NAME = MINUS_SWITCH_ONS DATA_TYPE = ASCII_INTEGER START_BYTE = 794 BYTES = 11 DESCRIPTION = "Number of instrument switch ons, negated" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 52 NAME = TOTAL_BYTES_TO_HEAP_SPACE DATA_TYPE = ASCII_INTEGER START_BYTE = 806 BYTES = 11 DESCRIPTION = "Total number of bytes sent to S/C encounter telemetry memory" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 53 NAME = MINUS_TOTAL_BYTES_TO_HEAP_SPACE DATA_TYPE = ASCII_INTEGER START_BYTE = 818 BYTES = 11 DESCRIPTION = "Total number of bytes sent to S/C encounter telemetry memory, negated" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 54 NAME = BYTES_TO_HEAP DATA_TYPE = ASCII_INTEGER START_BYTE = 830 BYTES = 11 DESCRIPTION = "Number of bytes in the S/C encounter telemetry memory, taking in to the account the partition limits" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 55 NAME = MINUS_BYTES_TO_HEAP DATA_TYPE = ASCII_INTEGER START_BYTE = 842 BYTES = 11 DESCRIPTION = "Number of bytes in the S/C encounter telemetry memory, taking in to the account the partition limits, negated" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 56 NAME = LARGE_LIMIT DATA_TYPE = ASCII_INTEGER START_BYTE = 854 BYTES = 11 DESCRIPTION = "Limit to consider event large, used only in s/w version 5" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 57 NAME = SPECTRUM_HI_BIN_LIMIT DATA_TYPE = ASCII_INTEGER START_BYTE = 866 BYTES = 11 DESCRIPTION = "Limit to consider, that a real event is in high sensitivity channel" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 58 NAME = SPECTRUM_LO_BIN_LIMIT DATA_TYPE = ASCII_INTEGER START_BYTE = 878 BYTES = 11 DESCRIPTION = "Limit to consider, that a real event is in low sensitivity channel" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 59 NAME = SPECTRUM_HI_LO_LIMIT DATA_TYPE = ASCII_INTEGER START_BYTE = 890 BYTES = 11 DESCRIPTION = "High sensitivity level limit to consider, that the low sensitivity channel is to be included" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 60 NAME = POLARITY_INDEX DATA_TYPE = ASCII_INTEGER START_BYTE = 902 BYTES = 11 DESCRIPTION = "Ion polarity, 0 = positive, 1 = negative" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 61 NAME = TRIGGER_PULSE_ADJUST DATA_TYPE = ASCII_INTEGER START_BYTE = 914 BYTES = 11 DESCRIPTION = "Value added to the pulse trigger DA after noise level calibration" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 62 NAME = TRIGGER_INTEGRAL_ADJUST DATA_TYPE = ASCII_INTEGER START_BYTE = 926 BYTES = 11 DESCRIPTION = "Value added to the integral trigger DA after noise level calibration" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 63 NAME = TARGET_TO_SMALL_LIMIT DATA_TYPE = ASCII_INTEGER START_BYTE = 938 BYTES = 11 DESCRIPTION = "Event rate in 1/s, when to switch to the small target" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 64 NAME = TARGET_TO_LARGE_LIMIT DATA_TYPE = ASCII_INTEGER START_BYTE = 950 BYTES = 11 DESCRIPTION = "Event rate in 1/s, when to switch to the large target" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 65 NAME = EVENT_NUMBER DATA_TYPE = ASCII_INTEGER START_BYTE = 962 BYTES = 11 DESCRIPTION = "Total number of events recorded" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 66 NAME = MINUS_EVENT_NUMBER DATA_TYPE = ASCII_INTEGER START_BYTE = 974 BYTES = 11 DESCRIPTION = "Total number of events recorded, negated" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 67 NAME = WAVELET_FILTER_LENGTH DATA_TYPE = ASCII_INTEGER START_BYTE = 986 BYTES = 11 DESCRIPTION = "Wavelet filter length" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 68 NAME = WAVELET_LOPASS DATA_TYPE = ASCII_REAL START_BYTE = 998 BYTES = 47 ITEMS = 4 ITEM_BYTES = 11 ITEM_OFFSET = 12 DESCRIPTION = "Wavelet low pass filter parameters" FORMAT = "F11.5" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 69 NAME = WAVELET_HIPASS DATA_TYPE = ASCII_REAL START_BYTE = 1046 BYTES = 47 ITEMS = 4 ITEM_BYTES = 11 ITEM_OFFSET = 12 DESCRIPTION = "Wavelet high pass filter parameters" FORMAT = "F11.5" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 70 NAME = NEGATIVE_PULSE_FACTOR DATA_TYPE = ASCII_INTEGER START_BYTE = 1094 BYTES = 11 DESCRIPTION = "Factor to multiply the pulse trigger DA setup value for negative ion mode in units of 1/16" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 71 NAME = NEGATIVE_INTEGRAL_FACTOR DATA_TYPE = ASCII_INTEGER START_BYTE = 1106 BYTES = 11 DESCRIPTION = "Factor to multiply the negative trigger DA setup value for negative ion mode in units of 1/16" FORMAT = "I11" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 72 NAME = SPARE DATA_TYPE = ASCII_INTEGER START_BYTE = 1118 BYTES = 1163 ITEMS = 97 ITEM_BYTES = 11 ITEM_OFFSET = 12 DESCRIPTION = "Not currently used" FORMAT = "I11" END_OBJECT = COLUMN