/* "CONT_LEVEL_3_FORMAT.FMT" Rosetta/MIRO continuum files calibrated data */ /* structure */ /* This structure label gives the data structure for the calibrated data from */ /* MIRO Millimeter and Submillimeter Continuum Radiometers. */ /* 13May2009 -lwk- removed GMT field (column 14) */ /* 28Oct2010 -lwk- added UTC field (column 5) */ OBJECT = COLUMN NAME = TIME COLUMN_NUMBER = 1 DATA_TYPE = IEEE_REAL FORMAT = "F16.5" UNIT = SECOND START_BYTE = 1 BYTES = 8 DESCRIPTION = "Time of start of acquisition of the data in elapsed UTC seconds after 1-Jan-1970 (see EAICD Section 3.2.2)." END_OBJECT = COLUMN OBJECT = COLUMN NAME = TIME1 COLUMN_NUMBER = 2 DATA_TYPE = IEEE_REAL FORMAT = "F16.5" UNIT = SECOND START_BYTE = 9 BYTES = 8 DESCRIPTION = "Time of acquisition of the 100th element of the raw data array, if summation=1, or of the 50th element if summation=2 or greater; this is zero if summation=0." END_OBJECT = COLUMN OBJECT = COLUMN NAME = TIME2 COLUMN_NUMBER = 3 DATA_TYPE = IEEE_REAL FORMAT = "F16.5" UNIT = SECOND START_BYTE = 17 BYTES = 8 DESCRIPTION = "Time of acquisition of the 100th element of the raw data array, if summation=2 or greater; otherwise zero." END_OBJECT = COLUMN OBJECT = COLUMN NAME = TIME3 COLUMN_NUMBER = 4 DATA_TYPE = IEEE_REAL FORMAT = "F16.5" UNIT = SECOND START_BYTE = 25 BYTES = 8 DESCRIPTION = "Time of acquisition of the 150th element of the raw data array, if summation=2 or greater; otherwise zero." END_OBJECT = COLUMN OBJECT = COLUMN NAME = UTC COLUMN_NUMBER = 5 DATA_TYPE = TIME FORMAT = "A19" START_BYTE = 33 BYTES = 19 DESCRIPTION = "Absolute time of start of acquisition of the data in the UTC system." END_OBJECT = COLUMN OBJECT = COLUMN NAME = MIRPOS COLUMN_NUMBER = 6 DATA_TYPE = MSB_UNSIGNED_INTEGER FORMAT = I1 START_BYTE = 52 BYTES = 1 DESCRIPTION = "Mirror position: 1: sky, 2: cold target, 3: warm target" END_OBJECT = COLUMN OBJECT = COLUMN NAME = POWERMODE COLUMN_NUMBER = 7 DATA_TYPE = MSB_UNSIGNED_INTEGER FORMAT = I1 START_BYTE = 53 BYTES = 1 DESCRIPTION = "Values 1-6 as described in MIRO User Manual 6.1.2.1.2" END_OBJECT = COLUMN OBJECT = COLUMN NAME = SUMMATION COLUMN_NUMBER = 8 DATA_TYPE = MSB_UNSIGNED_INTEGER FORMAT = I1 START_BYTE = 54 BYTES = 1 DESCRIPTION = "Values 0-4 as described in MIRO User Manual 6.1.2.1.2" END_OBJECT = COLUMN OBJECT = COLUMN NAME = ND COLUMN_NUMBER = 9 DATA_TYPE = MSB_UNSIGNED_INTEGER FORMAT = I3 START_BYTE = 55 BYTES = 1 DESCRIPTION = "Number of elements in raw data array; should always be 200." END_OBJECT = COLUMN OBJECT = COLUMN NAME = MMSUBTRACTION COLUMN_NUMBER = 10 DATA_TYPE = MSB_UNSIGNED_INTEGER FORMAT = I5 START_BYTE = 56 BYTES = 2 DESCRIPTION = "Offset in millimeter continuum data, as described in MIRO User Manual 6.1.4.1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = SMMSUBTRACTION COLUMN_NUMBER = 11 DATA_TYPE = MSB_UNSIGNED_INTEGER FORMAT = I5 START_BYTE = 58 BYTES = 2 DESCRIPTION = "Offset in submillimeter continuum data, as described in MIRO User Manual 6.1.4.1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = CALMODE COLUMN_NUMBER = 12 DATA_TYPE = MSB_UNSIGNED_INTEGER FORMAT = I1 START_BYTE = 60 BYTES = 2 DESCRIPTION = "0: Calibration in progress, 1: No calibration in progress" END_OBJECT = COLUMN OBJECT = COLUMN NAME = SP COLUMN_NUMBER = 13 DATA_TYPE = MSB_UNSIGNED_INTEGER FORMAT = I1 START_BYTE = 62 BYTES = 2 DESCRIPTION = "Spare, not used" END_OBJECT = COLUMN OBJECT = COLUMN NAME = D COLUMN_NUMBER = 14 DATA_TYPE = IEEE_REAL FORMAT = "200F6.0" UNIT = KELVIN START_BYTE = 64 BYTES = 800 ITEMS = 200 ITEM_BYTES = 4 DESCRIPTION = "Antenna temperatures" END_OBJECT = COLUMN