ROS GR GLOBAL FLAGS FROM PROCESS_OPTIONS FILE: -------------------------------- F Processing with Predict T Processing with AGC F Additional file containing the correct frequencies is needed T Active table of the X-band file contains the correct frequencies F Coherency flag is automatically set to false (i.e. one-way) NUMBER OF INPUT FILES: ---------------------- 00 Number of doppler S-band files 04 Number of doppler X-band files 04 Number of Meteo files 00 Number of AGC S-Band files 04 Number of AGC X-Band files FILES USED FOR PROCESSING: -------------------------- Z:\processed_temp\ros\2016\DOY_270_1874_ROS\MG11\D2\MG11_ROSE_2016_270_OP_D2_132944_0000 Z:\processed_temp\ros\2016\DOY_270_1874_ROS\MG11\D2\MG11_ROSE_2016_270_OP_D2_132944_0001 Z:\processed_temp\ros\2016\DOY_270_1874_ROS\MG11\D2\MG11_ROSE_2016_270_OP_D2_132944_0002 Z:\processed_temp\ros\2016\DOY_270_1874_ROS\MG11\D2\MG11_ROSE_2016_270_OP_D2_132944_0003 Z:\processed_temp\ros\2016\DOY_270_1874_ROS\MET\MG11_ROSE_2016_270_OP_ME_114433_0001 Z:\processed_temp\ros\2016\DOY_270_1874_ROS\MET\MG11_ROSE_2016_270_OP_ME_114433_0002 Z:\processed_temp\ros\2016\DOY_270_1874_ROS\MET\MG11_ROSE_2016_270_OP_ME_114433_0003 Z:\processed_temp\ros\2016\DOY_270_1874_ROS\MET\MG11_ROSE_2016_270_OP_ME_114433_0004 Z:\ddswork\process_data\CGIM_KLOBUCHAR_COEFFICENTS\2016\CGIM2700.16N Z:\processed_temp\ros\2016\DOY_270_1874_ROS\MG11\D2\MG11_ROSE_2016_270_OP_G2_121017_0001 Z:\processed_temp\ros\2016\DOY_270_1874_ROS\MG11\D2\MG11_ROSE_2016_270_OP_G2_121017_0002 Z:\processed_temp\ros\2016\DOY_270_1874_ROS\MG11\D2\MG11_ROSE_2016_270_OP_G2_121017_0003 Z:\processed_temp\ros\2016\DOY_270_1874_ROS\MG11\D2\MG11_ROSE_2016_270_OP_G2_121017_0004 FILES CREATED DURING PROCESSING: -------------------------------- Z:\processed_temp\ros\2016\DOY_270_1874_ROS\MG11\D2\R84ICL1L02_D2X_162701329_00.TAB Z:\processed_temp\ros\2016\DOY_270_1874_ROS\MG11\D2\R84ICL1L02_D2X_162701329_00.LBL CONFIGURATION INFO: -------------------- UPLINK-FREQUENCY X-BAND (R84ICL1L02_D2X_162701329_00.TAB): 7168430812.9980411529541016 DOWNLINK-FREQUENCY X-BAND (R84ICL1L02_D2X_162701329_00.TAB): 8422188405.1245346069335937 SAMPLE-INTERVAL X-BAND (R84ICL1L02_D2X_162701329_00.TAB): 10.0000000000000000 TRANSPONDER-RATIO X-BAND (R84ICL1L02_D2X_162701329_00.TAB): 880/749 LOOP BANDWIDTH X-BAND DOPPLER (R84ICL1L02_D2X_162701329_00.TAB): 100.0 LOOP BANDWIDTH X-BAND AGC (R84ICL1L02_D2X_162701329_00.TAB): 30.0 PROCESSING INFO --------------- AVERAGE X-BAND (R84ICL1L02_D2X_162701329_00.TAB) RESIDUALS IN mHZ: -9999999999.999 STANDARD DEVIATION X-BAND (R84ICL1L02_D2X_162701329_00.TAB) RESIDUALS IN mHZ: 0.000 PLASMA-CORRECTION DONE WITH KLOBUCHAR X-BAND-MODE: TWO-WAY SOFTWARE INFO: -------------- SOFTWARE NAME: ESA_IFMS_PROC_ICL_L1A_TO_L2_V4.1 CREATION TIME: 2019-05-16T15:19:03.000 PROCESSED BY: peter ERRORS: -------