This is a logfile for the ros measurement on 058 Times are given in the format YYYYMMDDhhmm GRV Measurement time: 201602270526 - 201602270736 Checking files of DOY 058 -------------------------------------------------- -------------------------------------------------- ++++++++++++++++++++++++++++++++++++ Sorting and checking CB11 D1-files ++++++++++++++++++++++++++++++++++++ CB11_ROSE_2016_058_OP_D1_052602_0000 CB11_ROSE_2016_058_OP_D1_052602_0001 CB11_ROSE_2016_058_OP_D1_052602_0002 Files stop too early at 201602270736 instead of 201602270736 The files cover the following time range 201602270526 - 201602270736 ++++++++++++++++++++++++++++++++++++ Sorting and checking CB11 AGC1-files ++++++++++++++++++++++++++++++++++++ CB11_ROSE_2016_058_OP_G1_050102_0000 CB11_ROSE_2016_058_OP_G1_050102_0001 CB11_ROSE_2016_058_OP_G1_050102_0002 Files stop too early at 201602270736 instead of 201602270736 The files cover the following time range 201602270501 - 201602270736 ++++++++++++++++++++++++++++++++++++ Sorting CL D1-files ++++++++++++++++++++++++++++++++++++ CB11_ROSE_2016_057_CL_D1_194121_0000 ++++++++++++++++++++++++++++++++++++ Sorting and checking CB11 D2-files ++++++++++++++++++++++++++++++++++++ CB11_ROSE_2016_058_OP_D2_052602_0000 CB11_ROSE_2016_058_OP_D2_052602_0001 CB11_ROSE_2016_058_OP_D2_052602_0002 Files stop too early at 201602270736 instead of 201602270736 The files cover the following time range 201602270526 - 201602270736 ++++++++++++++++++++++++++++++++++++ Sorting and checking CB11 AGC2-files ++++++++++++++++++++++++++++++++++++ CB11_ROSE_2016_058_OP_G2_050102_0000 CB11_ROSE_2016_058_OP_G2_050102_0001 CB11_ROSE_2016_058_OP_G2_050102_0002 Files stop too early at 201602270736 instead of 201602270736 The files cover the following time range 201602270501 - 201602270736 ++++++++++++++++++++++++++++++++++++ Sorting CL D2-files ++++++++++++++++++++++++++++++++++++ CB11_ROSE_2016_057_CL_D2_194121_0000 ++++++++++++++++++++++++++++++++++++ Sorting and checking CB11 MET-files ++++++++++++++++++++++++++++++++++++ CB11_ROSE_2016_057_OP_ME_195712_0009 CB11_ROSE_2016_057_OP_ME_195712_0010 CB11_ROSE_2016_057_OP_ME_195712_0011 Files stop too early at 201602270736 instead of 201602270736 The files cover the following time range 201602270457 - 201602270736 ++++++++++++++++++++++++++++++++++++ Sorting and checking Ranging-files ++++++++++++++++++++++++++++++++++++ CB11_ROSE_2016_058_OP_RG_050101_0000.raw CB11_ROSE_2016_058_OP_RG_050101_0001.raw CB11_ROSE_2016_058_OP_RG_050101_0002.raw Files stop too early at 201602270736 instead of 201602270736 The files cover the following time range 201602270530 - 201602270736 ++++++++++++++++++++++++++++++++++++ Sorting and checking Ranging-Cal-files ++++++++++++++++++++++++++++++++++++ CB11_ROSE_2016_057_CL_RG_194121_0000.raw ++++++++++++++++++++++++++++++++++++ Sorting and checking CB12 D1-files ++++++++++++++++++++++++++++++++++++ CB12_ROSE_2016_058_OP_D1_052603_0000 CB12_ROSE_2016_058_OP_D1_052603_0001 CB12_ROSE_2016_058_OP_D1_052603_0002 Files stop too early at 201602270736 instead of 201602270736 The files cover the following time range 201602270526 - 201602270736 ++++++++++++++++++++++++++++++++++++ Sorting and checking CB12 AGC1-files ++++++++++++++++++++++++++++++++++++ CB12_ROSE_2016_058_OP_G1_052603_0000 CB12_ROSE_2016_058_OP_G1_052603_0001 CB12_ROSE_2016_058_OP_G1_052603_0002 Files stop too early at 201602270736 instead of 201602270736 The files cover the following time range 201602270526 - 201602270736 ++++++++++++++++++++++++++++++++++++ Sorting and checking CB12 D2-files ++++++++++++++++++++++++++++++++++++ CB12_ROSE_2016_058_OP_D2_052603_0000 Wrong sample time of 0. for GRV-measurement in CB12_ROSE_2016_058_OP_D2_052603_0000 CB12_ROSE_2016_058_OP_D2_052603_0001 Wrong sample time of 0. for GRV-measurement in CB12_ROSE_2016_058_OP_D2_052603_0001 CB12_ROSE_2016_058_OP_D2_052603_0002 Wrong sample time of 0. for GRV-measurement in CB12_ROSE_2016_058_OP_D2_052603_0002 Files stop too early at 201602270736 instead of 201602270736 The files cover the following time range 201602270526 - 201602270736 ++++++++++++++++++++++++++++++++++++ Sorting and checking CB12 AGC2-files ++++++++++++++++++++++++++++++++++++ CB12_ROSE_2016_058_OP_G2_052603_0000 CB12_ROSE_2016_058_OP_G2_052603_0001 CB12_ROSE_2016_058_OP_G2_052603_0002 Files stop too early at 201602270736 instead of 201602270736 The files cover the following time range 201602270526 - 201602270736 ++++++++++++++++++++++++++++++++++++ Sorting and checking CB12 MET-files ++++++++++++++++++++++++++++++++++++ CB12_ROSE_2016_057_OP_ME_195713_0009 CB12_ROSE_2016_057_OP_ME_195713_0010 CB12_ROSE_2016_057_OP_ME_195713_0011 Files stop too early at 201602270736 instead of 201602270736 The files cover the following time range 201602270457 - 201602270736 ++++++++++++++++++++++++++++++++++++ Sorting and checking CB13 D1-files ++++++++++++++++++++++++++++++++++++ CB13_ROSE_2016_058_OP_D1_052604_0000 CB13_ROSE_2016_058_OP_D1_052604_0001 CB13_ROSE_2016_058_OP_D1_052604_0002 Files stop too early at 201602270736 instead of 201602270736 The files cover the following time range 201602270526 - 201602270736 ++++++++++++++++++++++++++++++++++++ Sorting and checking CB13 AGC1-files ++++++++++++++++++++++++++++++++++++ CB13_ROSE_2016_058_OP_G1_052604_0000 CB13_ROSE_2016_058_OP_G1_052604_0001 CB13_ROSE_2016_058_OP_G1_052604_0002 Files stop too early at 201602270736 instead of 201602270736 The files cover the following time range 201602270526 - 201602270736 ++++++++++++++++++++++++++++++++++++ Sorting and checking CB13 D2-files ++++++++++++++++++++++++++++++++++++ CB13_ROSE_2016_058_OP_D2_052604_0000 Wrong sample time of 0. for GRV-measurement in CB13_ROSE_2016_058_OP_D2_052604_0000 CB13_ROSE_2016_058_OP_D2_052604_0001 Wrong sample time of 0. for GRV-measurement in CB13_ROSE_2016_058_OP_D2_052604_0001 CB13_ROSE_2016_058_OP_D2_052604_0002 Wrong sample time of 0. for GRV-measurement in CB13_ROSE_2016_058_OP_D2_052604_0002 Files stop too early at 201602270736 instead of 201602270736 The files cover the following time range 201602270526 - 201602270736 ++++++++++++++++++++++++++++++++++++ Sorting and checking CB13 AGC2-files ++++++++++++++++++++++++++++++++++++ CB13_ROSE_2016_058_OP_G2_052604_0000 CB13_ROSE_2016_058_OP_G2_052604_0001 CB13_ROSE_2016_058_OP_G2_052604_0002 Files stop too early at 201602270736 instead of 201602270736 The files cover the following time range 201602270526 - 201602270736 ++++++++++++++++++++++++++++++++++++ Sorting and checking CB13 MET-files ++++++++++++++++++++++++++++++++++++ CB13_ROSE_2016_057_OP_ME_195714_0009 CB13_ROSE_2016_057_OP_ME_195714_0010 CB13_ROSE_2016_057_OP_ME_195714_0011 Files stop too early at 201602270736 instead of 201602270736 The files cover the following time range 201602270457 - 201602270736 ++++++++++++++++++++++++++++++++++++ The following files are missing: ++++++++++++++++++++++++++++++++++++ Wrong sample time of 0. for GRV-measurement in CB12_ROSE_2016_058_OP_D2_052603_0000 Wrong sample time of 0. for GRV-measurement in CB12_ROSE_2016_058_OP_D2_052603_0001 Wrong sample time of 0. for GRV-measurement in CB12_ROSE_2016_058_OP_D2_052603_0002 Ranging files for Gravity measurement missing for DOY 058 Ranging CL files for Gravity measurement missing for DOY 058 Wrong sample time of 0. for GRV-measurement in CB13_ROSE_2016_058_OP_D2_052604_0000 Wrong sample time of 0. for GRV-measurement in CB13_ROSE_2016_058_OP_D2_052604_0001 Wrong sample time of 0. for GRV-measurement in CB13_ROSE_2016_058_OP_D2_052604_0002 Ranging files for Gravity measurement missing for DOY 058 Ranging CL files for Gravity measurement missing for DOY 058