Austrian      Academy              of  Sciences
    Space    Research                Institute
Department   of Experimental            Space  Research

                ROSETTA-MIDAS
           To Planetary Science Archive Interface Control
                           Document

                       MID-IWF-TN-0087

                           Issue 2.0

                       16 November 2017

                                               ______________________________
                                                 Prepared by: Harald Jeszenszky

                                                   __________________________
                                                      Approved by: Mark Bentley
                                                 Document No.    : MID-IWF-TN-0087
          ROSETTA-MIDAS to PSA                   Issue/Rev. No.  : 2.0
          Interface Control Document             Date            : 16 November 2017
                                                 Page            : 2

                             Distribution List

Recipient                       Organisation                        Recipient
                                                          Document No.        : MID-IWF-TN-0087
                   ROSETTA-MIDAS to PSA                   Issue/Rev. No.      : 2.0
                   Interface Control Document             Date                : 16 November 2017
                                                          Page                : 3

                                        Change Log

         Date                          Sections Changed                    Reasons for Change

7 November 2003             All                                           First draft

6 February 2006             All                                           Updated draft

6 November 2006             All                                           First formal release

21 February 2008            All                                           Peer review update

27 October 2008                                                           Minor updates

1 February 2013             All                                           2nd peer review update

1 April 2016                All                                           3rd peer review update

16 November 2017            4.2.1 Updated data products table             October 2017 Science
                            4.2.6 Astronomical vs. MIDAS targets          Archive Review update
                            4.3.7 Added pixel scale attributes to label
                                             Document No.    : MID-IWF-TN-0087
      ROSETTA-MIDAS to PSA                   Issue/Rev. No.  : 2.0
      Interface Control Document             Date            : 16 November 2017
                                             Page            : 4

                              ITEMS

Section                                     Description
                                                              Document No.      : MID-IWF-TN-0087
                      ROSETTA-MIDAS to PSA                    Issue/Rev. No.    : 2.0
                      Interface Control Document              Date              : 16 November 2017
                                                              Page              : 5

                                           Table Of Contents

1   Introduction _________________________________________________________________________         7
  1.1    Purpose and Scope   _______________________________________________________________       7
  1.2    Archiving Authorities _____________________________________________________________       7
    1.2.1    ESA's Planetary Science Archive (PSA)____________________________________________     7
  1.3    Contents ________________________________________________________________________         7
  1.4    Intended Readership ______________________________________________________________        8
  1.5    Applicable Documents    ____________________________________________________________      8
  1.6    Relationships to Other Interfaces ___________________________________________________     8
  1.7    Acronyms and Abbreviations _______________________________________________________        8
  1.8    Contact Names and Addresses ______________________________________________________        9
2   Overview of Instrument Design, Data Handling Process and Product Generation ________________  10
  2.1    Scientific Objectives _____________________________________________________________      10
  2.2    AFM Operating Modes___________________________________________________________           11
  2.3    Operating Principle______________________________________________________________        12
  2.4    Data Handling Process   ___________________________________________________________      13
  2.5    Overview of Data Products   _______________________________________________________      13
    2.5.1    Pre-Flight Data Products _______________________________________________________     16
    2.5.2    Sub-System Tests   ____________________________________________________________      17
    2.5.3    Instrument Calibrations ________________________________________________________     17
    2.5.4    Other Files written during Calibration_____________________________________________  18
    2.5.5    In-Flight Data Products ________________________________________________________     18
    2.5.6    Software ___________________________________________________________________         19
    2.5.7    Documentation   ______________________________________________________________       22
    2.5.8    Derived and other Data Products_________________________________________________     22
    2.5.9    Ancillary Data Usage  _________________________________________________________      22
3   Archive Format and Content ___________________________________________________________        23
  3.1    Format and Conventions    _________________________________________________________      23
    3.1.1    Deliveries and Archive Volume Format ___________________________________________     23
    3.1.2    Data Set ID Formation  ________________________________________________________      23
    3.1.3    Data Set Name Formation ______________________________________________________       23
    3.1.4    Data Directory Naming Convention  ______________________________________________     23
    3.1.5    File Naming Convention _______________________________________________________       24
  3.2    Standards Used in Data Product  Generation _________________________________________     24
    3.2.1    PDS Standards_______________________________________________________________         24
    3.2.2    Time Standards ______________________________________________________________        24
    3.2.3    Reference Systems____________________________________________________________        25
    3.2.4    Other Applicable Standards_____________________________________________________      25
  3.3    Data Validation _________________________________________________________________        26
  3.4    Content ________________________________________________________________________         28
    3.4.1    Volume  Set / Data Set _________________________________________________________     28
                                                                 Document No.    : MID-IWF-TN-0087
                     ROSETTA-MIDAS to PSA                        Issue/Rev. No.  : 2.0
                     Interface Control Document                  Date            : 16 November 2017
                                                                 Page            : 6

    3.4.2    Directories __________________________________________________________________        28
4   Detailed Interface Specifications ________________________________________________________     32
  4.1    Structure and Organization Overview   ______________________________________________      32
    4.1.1    Data Processing Diagram  ______________________________________________________       32
    4.1.2    Data Product Preparation ______________________________________________________       33
  4.2    Data Sets, Definition and Content __________________________________________________      34
    4.2.1    Data Set Production___________________________________________________________        34
    4.2.2    Instrument Mode Definition ____________________________________________________       35
    4.2.3    Data Quality Definition ________________________________________________________      35
    4.2.4    Geometry Information _________________________________________________________        35
    4.2.5    Mission Specific Keywords_____________________________________________________        36
    4.2.6    Astronomical Targets vs. MIDAS Targets _________________________________________      37
  4.3    Data Product Design _____________________________________________________________         38
    4.3.1    Data Product Design - Standard Housekeeping Data _________________________________    38
    4.3.2    Data Product Design - Extended Housekeeping Data_________________________________     43
    4.3.3    Data Product Design - Frequency Scan Data _______________________________________     77
    4.3.4    Data Product Design - Single Point Approach Data __________________________________   82
    4.3.5    Data Product Design - Single Point Sampling Data __________________________________   88
    4.3.6    Data Product Design - Line Scan Data ____________________________________________     94
    4.3.7    Data Product Design - Image Scan Data___________________________________________      99
    4.3.8    Data Product Design - Feature Vector Data _______________________________________ 101
    4.3.9    Data Product Design - Event Data ______________________________________________ 107
    4.3.10   Data Product Design - Cantilever Utilisation History Data ___________________________ 109
    4.3.11   Data Product Design - Target Utilisation History Data ______________________________ 112
5   Appendix: Available Software to read PDS files ___________________________________________ 114
  5.1    Program Description ____________________________________________________________ 115
    5.1.1    Program Installation _________________________________________________________ 115
    5.1.2    Starting the Program _________________________________________________________ 115
    5.1.3    Navigating the Data Set_______________________________________________________ 115
    5.1.4    Data Display _______________________________________________________________ 115
  5.2    Program Source Files ___________________________________________________________ 116
    5.2.1    MIDAS Data Set Browser _____________________________________________________ 116
    5.2.2    Small Bodies Node (SBN) PDS Library __________________________________________ 117
6   Appendix: Example of Directory Listing of Data Set X _____________________________________ 118
                                                                   Document No.      : MID-IWF-TN-0087
                      ROSETTA-MIDAS to PSA                         Issue/Rev. No.    : 2.0
                      Interface Control Document                   Date              : 16 November 2017
                                                                   Page              : 7

1   Introduction

1.1   Purpose and Scope

      The purpose of this EAICD (Experimenter to (Science) Archive Interface Control Document) is
      twofold. At first, it  provides users of the  MIDAS   instrument  with a detailed  description of the
      product and a description and the methods by which it is generated, including data sources and
      destinations. Secondly, it is the official interface between the MIDAS instrument team and the
      archiving authority.

1.2   Archiving Authorities

      The Planetary Data System Standard is used as an archiving standard by
          NASA for U.S. planetary missions, implemented by PDS
          ESA for European planetary missions, implemented by the Research and Scientific Support
          Department (RSSD) of ESA

1.2.1  ESA's Planetary Science Archive (PSA)

      ESA implements an online science archive, the PSA,
          to support and ease data ingestion
          to offer additional services to the scientific user community and science operations teams as
          e.g.
           o    search queries that allow searches across instruments, missions and scientific
                disciplines
           o    several data delivery options as
                    direct download of data products, linked files and data sets
                    ftp download of data products, linked files and data sets

      The  PSA   aims    for online ingestion  of logical archive volumes  and  will offer the creation  of
      physical archive volumes on request.

1.3   Contents

      This document describes the data flow of the MIDAS instrument on ROSETTA from the S/C until
      insertion into the PSA for ESA. It includes information on how data were processed, formatted,
      labelled and uniquely    identified. The document    discusses  general  naming    schemes  for data
      volumes, data sets, data and label files. Standards used to generate the product are explained.
      Software that may be used to access the product is explained further on.
      The design of the data set structure and the data product is given. Examples of these are given
      in the appendix.
                                                            Document No.     : MID-IWF-TN-0087
                    ROSETTA-MIDAS to PSA                    Issue/Rev. No.   : 2.0
                    Interface Control Document              Date             : 16 November 2017
                                                            Page             : 8

1.4  Intended Readership

     The staff of the archiving authority (Planetary Science Archive, ESA, RSSD, design team) and
     any potential user of the MIDAS data.

1.5  Applicable Documents

     [1]       Planetary Data System Data Preparation Workbook
               February 17, 1995, Version 3.1, JPL D-7669, Part1
     [2]       Planetary Data System Standards Reference
               August 1, 2003, Version 3.6, JPL D-7669, Part 2
     [3]       ROSETTA Archive Generation, Validation and Transfer Plan
               October 6, 2005, Issue 2.2, RO-EST-PL-5011
     [4]       ROSETTA Experiment Interface Document - Part A
               February 1, 2004, Issue 2, Rev. 3, RO-EST-RS-3001/EIDA
     [5]       ROSETTA - MIDAS Experiment Interface Document - Part B
               February 15, 2001, Issue 2d, Rev. 0, RO-EST-RS-3010/EIDB
     [6]       ROSETTA - Data Delivery Interface Document (DDID)
               October 23, 2003, Issue B6, RO-ESC-IF-5003
     [7]       MIDAS User Manual
               February 23, 2004, Issue 2, Rev. 1, MID-IWF-UM-0047
     [8]       ROSETTA Time Handling
               February 28, 2006, Issue 1, Rev. 1, RO-EST-TN-3165
     [9]       MIDAS Co-ordinate Systems
               October 28, 2008, Issue 1.0, MID-IWF-TD-0029

1.6   Relationships to Other Interfaces

     N/A

1.7  Acronyms and Abbreviations

     AFM              Atomic Force Microscope
     DAQ              Data Acquisition
     DDID             Data Delivery Interface Document
     DDS              Data Disposition System
     EAICD            Experimenter to (Science) Archive Interface Control Document
     EGSE             Electrical Ground Support Equipment
     FM               Flight Model
     FS               Flight Spare Model
                                                          Document No.      : MID-IWF-TN-0087
                   ROSETTA-MIDAS to PSA                   Issue/Rev. No.    : 2.0
                   Interface Control Document             Date              : 16 November 2017
                                                          Page              : 9

     IDL             Interactive Data Language
     IWF/OAW         Space Research Institute of the Austrian Academy of Sciences
     JPL             Jet Propulsion Laboratory
     LVDT            Linear Variable Differential Transformer
     MIDAS           Micro-Imaging Dust Analysis System
     N/A             Not applicable
     NAIF            The Navigation and Ancillary Information Facility, JPL/NASA
     NASA            National Aeronautics and Space Administration
     OBT             S/C On-board Time (Spacecraft Elapsed Time according to [4])
     PDS             Planetary Data System
     PSA             Planetary Science Archive
     QM              Qualification Model
     SCET            Spacecraft Event Time (according to [6])
     SPM             Scanning Probe Microscope
     STM             Scanning Tunneling Microscopy
     TB/TV           Thermal Balance/Thermal Vacuum

1.8  Contact Names and Addresses

     Mark Bentley, IWF/OAW, mark.bentley@oeaw.ac.at, +43 (0)316 4120 657
     Harald Jeszenszky, IWF/OAW, harald.jeszenszky@oeaw.ac.at, +43 (0)316 4120 533
     Jens Romstedt, ESA/ESTEC, jens.romstedt@esa.int, +31 (0)71 565 5761
                                                                   Document No.      : MID-IWF-TN-0087
                      ROSETTA-MIDAS to PSA                         Issue/Rev. No.    : 2.0
                      Interface Control Document                   Date              : 16 November 2017
                                                                   Page              : 10

2   Overview of Instrument Design, Data Handling Process and
    Product Generation

2.1  Scientific Objectives

     The experiment MIDAS (Micro-Imaging Dust Analysis System) is dedicated to the micro textural
     and statistical analysis of cometary dust particles. The instrument is based on the technique of
     atomic force microscopy. Under the conditions prevailing at the Rosetta Orbiter this technique
     permits textural and other analysis of dust particles to be performed down to a spatial resolution
     of 4 nm.

     During the rendezvous with the comet MIDAS will provide the following information:
             images of single particles with a spatial resolution of 4 nm,
             statistical evaluation of the particles according to size, volume, and shape,
             size distribution of particles ranging from about 4 nm to a few um,
             shape, volume and topographic structure of individual particles,
             temporal variation of particle fluxes,
             spatial variation of particle fluxes, and
             measurements on local elastic properties if further studies show that they do not affect
             the tip lifetime

     During the cruise phase to the comet MIDAS may provide:
             characterization of the dust environment in the vicinity of the asteroids for which a fly-by
             is performed
             imaging of impact craters caused by fast interplanetary dust particles, and
             statistical analysis of craters on the exposed surface in terms of particle size and volume

     MIDAS will deliver global images, i.e. complete images of the entire scan field, and images of
     individual  dust particles. The  latter  are contained   in the former,  since selected   particles are
     identified from  the global   image. These     particles  are then   re-scanned   with a much   higher
     resolution. The   measurements    by the    MIDAS   instrument  will address   many  of  the questions
     related to  cometary   dust. In particular,  the MIDAS    instrument  can measure    and  address   the
     following qualities of the collected dust grains:
             3D images of single particles
             Images of the textural complexity of particle aggregates
             Identification   of  crystalline  material  if  idiomorphic  or hypidiomorphic    shapes    are
             developed
             Identification of sub-features on clean surfaces which provides insight into the growth
             conditions (e.g. twinning defects) and/or storage environment (e.g. dissolution marks)
             Statistical evaluation of the particles according to size, volume and shape
                                                                        Document No.        : MID-IWF-TN-0087
                        ROSETTA-MIDAS to PSA                            Issue/Rev. No.      : 2.0
                        Interface Control Document                      Date                : 16 November 2017
                                                                        Page                : 11

               Variation   of particle  fluxes  between    individual exposures    of  the collector unit  on  time
               scales of hours
               Four out of the sixteen sensors are capable of detecting a magnetic gradient between
               sensor   and    sample   and     allow  the   identification of  ferromagnetic    minerals   or   the
               visualisation of the internal magnetic structure of a grain.

2.2  AFM Operating Modes

     Contact mode
     The working point is set close to the repulsive force regime where the tip actually touches the
     surface.  Typically,   a  force of  the  order   10-7-10-6  N   is  exerted  on  the  sample.  Owing     to the
     strongly increasing repulsive force at decreasing distances, the tip cannot penetrate deeply into
     the surface and the soft cantilever bends. However, the pressure exerted by the tip is high and
     soft samples, particularly, can be scratched or damaged.

     Dynamic mode
     The  cantilever    is excited  at  its natural  mechanical   resonance     frequency     (100  kHz)   at close
     distance   to  the  sample.    The    amplitude   of  the cantilever   vibration  is  of the  order  100    nm.
     Depending     on   the  operational    setting, the tip may  or  may   not   touch the   sample during   each
     oscillation. At small tip-sample separation of the order 5-10 nm, the interaction of the electron
     orbits results in a weak attractive force, and the resonance frequency of the cantilever changes
     owing to a virtual increase in its spring constant. The quantity thereby measured is not the force
     directly, but  its gradient.   As  in  the contact   mode,  vertical   resolution  in the nm   range  can   be
     achieved. The force applied by the tip to the sample is of the order 10-8 N. This relatively small
     force and the absence of lateral forces makes damage to the tip less likely, and the lifetime of
     the tip increases considerably. The lateral resolution obtained in dynamic mode is comparable to
     that  of  the  contact    mode.    However,     dynamic   mode     images    often   represent  not  only   the
     topography, but also to some extent the elastic properties of the sample under investigation. The
     mechanical     resonance      frequency     of   the  cantilever    has   to  be   determined   before      any
     measurement in dynamic mode.

     Magnetic force microscopy
     This  derivative   of   atomic  force   microscopy      (Martin  and   Wickramasinghe,     1987)  records     a
     magnetostatic force between sample and a magnetised tip. Four of the MIDAS tips have been
     coated    with a   thin  layer  of cobalt.  The     deflections  of their  cantilevers   then  result from    a
     combination of mechanical and magnetic forces, which can be separated by measurements at
     two different tip-sample distances. These tips map the magnetic structures of the particles in
     addition to the topographies.
                                                                    Document No.        : MID-IWF-TN-0087
                       ROSETTA-MIDAS to PSA                         Issue/Rev. No.      : 2.0
                       Interface Control Document                   Date                : 16 November 2017
                                                                    Page                : 12

2.3  Operating Principle

     MIDAS    is  designed    to analyse  micro   dust  particles collected  in the  cometary    environment,
     irrespective of their electrical conductivity and shape, by means of atomic force microscopy. The
     size  of the particles   which  can  be   analysed ranges  from   about  4 nm   to   a few  um.  The   dust
     collector system     includes a   shutter mechanism    which  controls  the particle   flux onto   a wheel
     covered with special coating to provide maximum adhesion for the particles. Sixty-one separate
     targets at the wheel are available for subsequent exposure to the ambient dust flux. The MIDAS
     microscope      consists of  five functional parts:  a one   shot  cover  and  a funnel     to protect  the
     aperture on the ground and during launch, the shutter to define the exposure time to the dust
     flux, the   robotics system   for  manipulation   of the dust  particles,  the scanner     head,   and  the
     supporting electronics.

                                       Fig. 2.1 - MIDAS Working Principle

     At the heart of the atomic force microscope (AFM) is a very small tip which maps the surface of
     the particle. An AFM is capable, in principle, of imaging details down to atomic resolution. In the
     simplest  case,   the tip   remains  in permanent    contact  with the  surface  and    follows  its height
     variations with a control mechanism which keeps a constant force on the tip (contact mode). In a
     technically more complex mode, the tip scans the surface while its supporting cantilever vibrates
     at one   of its natural  resonance   frequencies.   Depending   on  the amplitude    of the  oscillation in
     dynamic mode, (a) the tip does not come closer to the surface than a few tenths of a nanometre
     (non-contact mode) or (b) the tip hits the surface during its sinusoidal oscillation (tapping mode).
     In all modes it is essential either to keep the force constant or to measure it accurately in order
     to derive an image of the surface.
     The tip must move over the surface in a reproducible manner, which can be relatively easily
     achieved by piezo electric scanners in three independent directions. The combination of the tip,
     supporting   cantilever,    and piezo-electric actuators  is  called  scanner    head.   Due    to   lifetime
     requirements, several tips will be employed (16 in total).
                                                                 Document No.      : MID-IWF-TN-0087
                      ROSETTA-MIDAS to PSA                       Issue/Rev. No.    : 2.0
                      Interface Control Document                 Date              : 16 November 2017
                                                                 Page              : 13

2.4  Data Handling Process

     The data products will be prepared and delivered by IWF/OAW in collaboration with partners
     from ESTEC. A list of contact persons, phone numbers and email addresses is given in section
     1.8.
     All  data products  are planned     to be  level 1b  and/or level  2  data (PSA   processing  label)
     throughout the whole mission lifetime. Higher level data products will be included in the final
     archive volume distribution.
     It is foreseen to use most of the already developed EGSE software modules for data processing.
     This software will be adapted to generate the data products from the raw data archive (locally
     stored laboratory data as well as DDS data after launch).

2.5  Overview of Data Products

     The   table below   shows   the  data  products  which  are intended   to  be archived.  A  detailed
     description of the different data types follows.

      Data Type                                               Type Mnemonic          PDS Data Type
      Housekeeping Data (Standard, Extended)                  HK1, HK2               TABLE
      Frequency Scan Data                                     FSC                    SERIES
      Single Point Approach Data (Control Data)               SPA                    TABLE
      Single Point Sampling Data (High Resolution Data)       SPS                    SERIES
      Line Scan Data                                          LIN                    TABLE
      Image Scan Data                                         IMG                    IMAGE
      Feature Vector Data (Regions Of Interest)               ROI                    TABLE
      Event Data                                              EVN                    TABLE
      Cantilever Utilisation History                          CAH                    TABLE
      Target Utilisation History                              TGH                    TABLE

                                  Table 2.1 - MIDAS Archive Data Products

     Housekeeping Data
     MIDAS generates two types of housekeeping data:
             The standard housekeeping report contains basic information and reflects the "general
             condition" of the instrument (e.g. voltage monitors, temperatures).
             The much larger extended housekeeping report includes the status of the instrument
             sub-systems   (e.g.  linear stage, approach)   and  all parameters  related  to the science
             operations.
     Typical data cadences are 4 seconds for the standard HK report and 8 seconds for the extended
     HK   report  for laboratory  generated    data.  The individual  data rates   can  be changed   via
     telecommand and will be much lower during normal flight operations.
                                                           Document No.      : MID-IWF-TN-0087
                ROSETTA-MIDAS to PSA                       Issue/Rev. No.    : 2.0
                Interface Control Document                 Date              : 16 November 2017
                                                           Page              : 14

Frequency Scan Data
In order  to set the   operating point  (excitation frequency)  for a certain  cantilever   (tip), the
resonance frequency has to be determined. This is achieved by performing a frequency sweep
in a commanded frequency range. The operating point is set relative to the detected resonance
amplitude.  A  frequency  scan  produces  up  to 8  data packets  (depending   of the commanded
frequency range and resolution) of 256 data acquisition points each.

The frequency scan is performed
         every time approaching the surface,
         whenever a new tip is selected, or
         during long-lasting (dynamic) scans when re-adjustment of the frequency is required.

The  cantilevers (tips)  are numbered    from 1  to  16  and are  addressable   by  2 blocks     of  8
cantilevers each (physically the cantilevers are structured into four cantilever arrays):

                                                                    Cantilever selection
   Tip #     Description
                                                               Block #             Cantilever #
    1-4      Cantilever array #1                                  1                       1-4
    5-8      Cantilever array #2                                  1                       5-8
   9-12      Cantilever array #3                                  2                       1-4
   13-16     Cantilever array #4 (cobalt coated)                  2                       5-8

Tip, cantilever block and cantilever number are also present in the extended housekeeping data
product. Please note that the cantilever number ranges from 0 to 7 in this data product.

Single Point Approach Data
The  MIDAS    instrument  software is  capable   of monitoring selected  data  acquisition    process
parameters (cantilever AC, DC and phase signal; Z set value) simultaneously in a single scan
position. This feature  can  be  enabled  or  disabled  when   performing a  line scan    and   is not
available for the full image scan. The associated data packet contains the last 256 processed
parameter values before the measurement reading is recorded. During a line scan, 32 uniformly
distributed  positions are   monitored. The   parameter   MAIN_SCAN_CNT        indicates    the  pixel
number within the line where the approach vector has been recorded.

Single Point Sampling Data
The data acquisition monitoring structure is also used for a more complex instrument mode.
This "high resolution" scanning mode allows the sampling of the above-mentioned parameters
with a frequency of up to 700 samples per second. The scanner head remains in the same X/Y
position  when taking   the data samples   (STEP_SIZE    parameter   is 0). Thus  the Single    Point
Sampling data product corresponds to a single point located on the target surface.
By getting into contact with the surface (static or DC mode), the cantilever DC signal can be
used to measure micro-vibrations with a maximum frequency of 350 Hz. This mode is frequently
used during the pointing and interference scenario.
                                                            Document No.    :   MID-IWF-TN-0087
               ROSETTA-MIDAS to PSA                         Issue/Rev. No.  :   2.0
               Interface Control Document                   Date            :   16 November 2017
                                                            Page            :   15

In order to detect possible micro-vibrations, a Fast Fourier Transform (FFT) has to be applied to
the DC    sample vector. Analysis  of the   resulting frequency  spectrum  will give  an indication
(spectral lines with higher amplitude) on micro-vibrations.

Line Scan Data
Additionally to the full image scan, MIDAS is able to scan single lines in either X or Y direction.
The  line scan values  have   two different meanings    depending  on the  commanded      scanning
mode:
       In dynamic or contact mode the Z piezo set values at the surface are stored in the line
       scan.
       In magnetic mode the differences of the cantilever AC signals at the surface and at a
       given distance from the surface are recorded.
The size of a line scan is a multiple of 32, ranging from 32 to a maximum of 512 DAQ points.

Image Scan Data
The image scan is the key operation of the instrument MIDAS. The on-board image memory of 1
MB can hold a maximum of 8 standard images (256x256 pixel / 1 DAQ channel = 128 kB). The
image dimensions are multiples of 32 pixels, ranging from 32 to a maximum of 512 DAQ points.
During a single image scan up to 8 data channels can be measured in parallel. At the present
time 14 data channels are available (the value in curly braces gives the calibration curve number
as defined in the calibration table MIDCALIB.TAB defined in chapter 3.4.2.2):
       [ZS]    Z piezo set value (this is the default channel for all scanning modes) {40}
       [AC]    Cantilever AC signal at surface (required for magnetic mode) {3}
       [PH]    Cantilever Phase signal {13}
       [DC]    Cantilever DC signal {3}
       [XH,YH,ZH]      X, Y, Z piezo high voltage monitor {8}
       [M1,M2,M3]      Cantilever AC signal at (magnetic) retract position 1,2,3 {3}
       [YP,ZP]     Y, Z piezo position (measured) {3}
       [YE,ZE]     Y, Z piezo offset error (control loop deviation set value / measured value) {3}
       [S1,S2]     Data point acquisition status information
If more than one data channel is selected for a scan, the software generates a separate image
for every channel.

Feature Vector Data
Another facet of the instrument software is the calculation of so-called "feature vectors" for an
already acquired image. These vectors are providing statistical information (10 parameters in
total) of features found in the image, for example area or volume. The features are selected
dependent   on a   number  of commandable     criteria. By  weighting the  selection  criteria, it is
possible to determine a feature which suits best the given requirements. The coordinates of the
determined feature can then be used to automatically zoom-in into the underlying image.
A maximum of 1024 feature vectors can be stored for a single image. The vectors are packed
into statistical data packets containing 64 vectors each.
                                                                 Document No.        : MID-IWF-TN-0087
                      ROSETTA-MIDAS to PSA                       Issue/Rev. No.      : 2.0
                      Interface Control Document                 Date                : 16 November 2017
                                                                 Page                : 16

      Event Data
      Every  task  (e.g. mechanical   sub-system  movement,    scan,  image  processing)     running  on  the
      instrument has associated a number of events providing information about the status of the task
      (e.g. started, finished and aborted). In order to keep track of the task execution, the events will
      also be part of the MIDAS data archive.
      A list of events is given in the MIDAS User Manual in section 2.3.3.1 "TM data packet overview".

      Cantilever Utilisation History Data
      The MIDAS scanner head holds 16 different cantilevers (tips) mainly for redundancy purposes,
      and four of these tips are coated with magnetic material and may be used for magnetic mode
      scans. For the interpretation of the AFM images it is necessary to know the history of the tip
      which   has  been   used for the   image  acquisition. A  list of  operating  times   and  associated
      scanning parameters (e.g. scanning mode, gain levels and excitation level) will be stored for
      each cantilever.
      The cantilever history files are cumulative, containing the data from the start of the mission up to
      and including the mission phase represented in a dataset.

      Target Utilisation History Data
      For each  of  the  64 scanning   targets (including the three   calibration targets)  a list of events
      concerning the target will be maintained and stored in the archive. Dedicated information like the
      dust flux during exposure recorded by GIADA or the scanning tip number will be stored in this
      table.
      The targets  are   numbered  from   1 to 64  and each   target  is subdivided    into 16 addressable
      segments (or scan bands). This results in a total number of 1024 addressable target segments.
      The segments are numbered from 0 to 1023, with segment 0 referring to the centre of target 1:

       Target #    Description                                           Addressed by segment #
                                                                     Min          Centre           Max
          1        Dust collector target                             1017            0                7
          2        TGZ02 - Z calibration (106 nm height)              9             16              23
          3        TGX01 - used for X/Y calibration                   25            32              39
          4        TGT01 - X/Y calibration and tip imaging            41            48              55
          5        Dust collector target                              57            64              71
          ...
          64       Dust collector target                             1001          1008            1015

      The target history files are cumulative, containing the data from the start of the mission up to and
      including the mission phase represented in a dataset.

2.5.1  Pre-Flight Data Products

      MIDAS   will provide  laboratory data  from  the TB/TV   acceptance    tests  of  the  FM.   Since  the
      generation of the feature vectors was not implemented in the instrument S/W at that time, it is
      also intended to create a data set from dedicated FS or QM tests.
                                                                  Document No.                        : MID-IWF-TN-0087
                   ROSETTA-MIDAS to PSA                           Issue/Rev. No.                      : 2.0
                   Interface Control Document                     Date                                : 16 November 2017
                                                                  Page                                : 17

2.5.2  Sub-System Tests

      A series of micro-vibration tests were performed on the QM.

2.5.3  Instrument Calibrations

      X/Y/Z Calibration
      The X-, Y- and Z-sensors of the MIDAS instrument are calibrated by means of three reference
      grids which are mounted on the target wheel. These reference grids are scanned on a more or
      less regular basis in order to re-calibrate the scanner head:

             TGX01 - used for X/Y calibration

             The silicon calibration grating of the TGX series
             is a chessboard-like array of square pillars with
             sharp undercut edges formed by (110)
             crystallographic planes of silicon.

             TGZ02 - Z calibration (106 nm height)

             Calibration gratings of the TGZ series are 1-D
             arrays of rectangular SiO2 steps on a Si wafer.
             The structure is coated by Si3N4 to prevent Si
             from oxidation. The step height value is
             calibrated over the whole active area.

             TGT01 - X/Y calibration and tip imaging

             The silicon calibration grating of the TGT01
             series is an array of sharp tips, characterized by
             strict symmetry of tip sides, small cone angle
             (less than 20 degrees) and small curvature
             radius of the tips (less than 10 nm) over the
             whole active area.

         The dimensions marked (*) show approximate values and are given for information only.

      The archive will contain the following calibration data:
             Tip resonance curves as a function of the excitation frequency in [V]
             Tip positions as a function of the linear stage LVDT monitor in [V] and [um] (see [9])
             Tip images acquired by sampling calibration grating TGT01
             X/Y step calibration (can be derived from sampling calibration grating TGX01)
             Z step calibration (can be derived from sampling calibration grating TGZ02)
             HK parameter conversion from raw to physical values
                                                                                 0.7 um*
                                                                Document No.    :  MID-IWF-TN-0087
                      ROSETTA-MIDAS to PSA                      Issue/Rev. No.  :  2.0
                      Interface Control Document                Date            :  16 November 2017
                                                                Page            :  18

2.5.4  Other Files written during Calibration

      Numerous     reference  measurements      with  commercial  AFM's    (Zeiss,  Park)  have  been
      performed. The resultant image database is used as reference for the analysis and interpretation
      of MIDAS generated images.

2.5.5  In-Flight Data Products

      A list of data products as well as a detailed description is already provided at the beginning of
      section 2.5.
      The data products   are  planned    to be level 1b and/or  level 2 data  (PSA  processing label)
      throughout the whole mission lifetime. Higher level data products are likely to be included in the
      final archive volume distribution.
                                                               Document No.      : MID-IWF-TN-0087
                     ROSETTA-MIDAS to PSA                      Issue/Rev. No.    : 2.0
                     Interface Control Document                Date              : 16 November 2017
                                                               Page              : 19

2.5.6   Software

2.5.6.1   Data Archiving Software

      The MIDAS data archiving software is a graphical user interface written in IDL and is used to
      prepare the MIDAS archive data sets to be delivered to the PSA.

                                  Fig. 2.2 - MIDAS Data Archiving S/W
      Key features of the archiving software are:
              Data sets are created directly from the MIDAS raw data archive by means of data set
              templates which are completed during data processing.
              The S/W  is capable of managing      so called "data set profiles" in order to ease re-
              production of entire data sets.
                                                                  Document No.    :    MID-IWF-TN-0087
                       ROSETTA-MIDAS to PSA                       Issue/Rev. No.  :    2.0
                       Interface Control Document                 Date            :    16 November 2017
                                                                  Page            :    20

              A number of label verification tools (PVV, NASA PDS tools) are already integrated into
              the archiving software. This allows the user to validate the data sets immediately after
              generation.

2.5.6.2   Data Verification Software

     This software is used to display and validate the contents of an entire MIDAS archive data set
     interactively. The software is entirely written in IDL and the source code is included in the data
     sets. The source files (extension *.PRO) are located in the DOCUMENT directory of a data set.
     A detailed description of the software is provided in section 5.

2.5.6.3   Third Party Software Packages

     NASAView
     NASAView     (http://pds.nasa.gov/tools/nasa-view.shtml)     is  a  PDS   archive     product  display
     program that runs on multiple platforms in a GUI environment. The tool can be used to view the
     MIDAS images located in the DATA/IMG directory.

                             Fig. 2.3 - MIDAS Image taken during LUTETIA Fly-by
     PDS Tools Package
     The PDS Tools Package (http://pds.nasa.gov/tools/pds-tools-package.shtml) is the complete set
     of PDS Engineering Node supported tools. This package contains a single installer file which
     includes the option to install the following tools:
              Keyword    Definition (ddict): Lists all keywords and  their definitions from  the specified
              file(s).
              Keyword Verifier (kwvtool): Lists all keywords and a distinct set of their values from the
              specified file(s).
                                                            Document No.    : MID-IWF-TN-0087
              ROSETTA-MIDAS to PSA                          Issue/Rev. No.  : 2.0
              Interface Control Document                    Date            : 16 November 2017
                                                            Page            : 21

       Label Parser: The Java-based label parser parses an ODL label and generates an XML
       representation.
       Label Verifier (lvtool): Performs validation of PDS labels.
       Line Analyzer (line): Analyzes each line of a file and reports anomalies.
       Make Index (make_index): Creates an index file (pdsdd.idx) from a data dictionary file
       (pdsdd.full).
       Perl Validation Toolkit: Validates PDS volumes (includes lvtool and kwvtool).
       Table Checker (table_check): Performs a variety of tests on PDS table objects.
       Table to Label Generator (tab2lab): Generates PDS labels from values in a table.
       Table Verifier  (tbtool): Utility for validating, browsing  and summarizing   data that is
       organized by rows and columns and is described by a PDS label.
The PDS Tools Package also includes libraries which are utilized by the tools listed above and
are available for use in customized applications:
       Label Library (lablib): This library, written in C, can be used to read, process and write
       PDS labels.
       Label Library Light (lablib3): This library, written in C, can be used to read, process and
       write PDS labels. Compared to lablib, this library is smaller, faster and has a simpler
       interface.
       ODLC Library (odlc): This library, written in C, can be used to access data that meet the
       standards of the PDS.
       Object Access Library (oal): This library, written in C, can be used to access data that
       meet the standards of the PDS.
                                                           Document No.    : MID-IWF-TN-0087
                    ROSETTA-MIDAS to PSA                   Issue/Rev. No.  : 2.0
                    Interface Control Document             Date            : 16 November 2017
                                                           Page            : 22

2.5.7  Documentation

      The following documents will be included in the MIDAS archive DOCUMENT directory:
             MIDAS User Manual
             MIDAS EAICD
             MIDAS Co-ordinate Systems
             MIDAS instrument paper as presented in the Space Science Review (2007)
      These documents are converted to ASCII format. Associated drawings are stored as "Portable
      Network Graphic" (PNG) files.
      In addition, PDF versions of the listed documents are available from the same directory.

2.5.8  Derived and other Data Products

      N/A

2.5.9  Ancillary Data Usage

      N/A
                                                                   Document No.      : MID-IWF-TN-0087
                   ROSETTA-MIDAS to PSA                            Issue/Rev. No.    : 2.0
                   Interface Control Document                      Date              : 16 November 2017
                                                                   Page              : 23

3   Archive Format and Content

3.1   Format and Conventions

3.1.1  Deliveries and Archive Volume Format

      The logical archive volumes will contain one data set per volume. Up to now, three basic types
      of logical archive volumes are planned:
             Selected laboratory data
             Checkout data generated during flight (cruise phase)
             Data acquired in the close comet environment (cometary phase)

3.1.2  Data Set ID Formation

      The MIDAS data set identifiers are defined as follows (see archive plan [3]):
             "RO-{target ID}-MIDAS-{level}-{phase}-{description}-Vx.y"
      {target ID} = {C, A,  E, M,  CAL,    X,   D,  SS,   C}
      {level} = processing level = {3, 5}
      {phase} = mission phase = {GRND,     CVP,   CR1,    ...}
      {description} = free character string containing only A-Z,     0-9 (e.g. TV)

3.1.3  Data Set Name Formation

      The MIDAS data set names are defined as follows (see archive plan [3]):
             "ROSETTA-ORBITER       {target name}   MIDAS       {level} {phase} {description} Vx.y"
      {target name} = {67P,   STEINS,     LUTETIA,   ...}
      {level} = processing level = {3, 5}
      {phase} = mission phase = {GRND,     CVP,   CR1,    ...}
      {description} = free character string containing A-Z,    0-9,     - (e.g. TV-TEST)

3.1.4  Data Directory Naming Convention

      For all data sets the data directory is structured as follows:
             /DATA[/{data type}]/file(s)
      {data type} = {EVN,  FSC,  HK1,     HK2,  IMG,  LIN,       ROI,    SPA,  SPS}
      Cantilever and target history files (CAH, TGH) are stored in the data directory root.
                                                                  Document No.     : MID-IWF-TN-0087
                   ROSETTA-MIDAS to PSA                           Issue/Rev. No.   : 2.0
                   Interface Control Document                     Date             : 16 November 2017
                                                                  Page             : 24

3.1.5  File Naming Convention

      The following file naming scheme will be used for all data sets (the "extra" field is optional and
      depends on the data type):
             {data type}_{start}_{stop}[_{extra}].{ext}
      {data type} = {CAH, EVN,   FSC,  HK1,  HK2,    IMG,    LIN,     ROI,  SPA,   SPS,   TGH}
      {start} = begin of observation rounded to nearest hour, format = yydddhh
      {stop} = end of observation rounded to nearest hour, format = yydddhh
      {extra} = more specific information about the file content:

               data type          extra information               possible values          field format
               HK1, HK2,EVN                                       not used
               FSC, SPA,          sequence counter [nnn]          001..FFFSPS, LINtip number [tt]01..16nnn_tt
                                  sequence counter [nnn]          001..999
               IMG                DAQ channel [dd]                ZS,  AC,  PH,   DC,M1,M2,M3,XH,nnn_dd
                                                                  YH,  ZH,  YP,   ZP,
                                                                  YE,  ZE,  S1,   S2*)
                                  sequence counter [nnn]          001..999
               ROI                                                                          nnn_ff
                                  target number [ff]              01..64
               CAH                tip number [tt]                 01..16                       tt
               TGH                target number [ff]              01..64                       ff
              *) A description of the DAQ channels is given in section 2.5 (Image Scan Data).

      {ext} = depends on the data type (e.g. IMG for images, DAT/TAB for binary/ASCII tables)

3.2   Standards Used in Data Product Generation

3.2.1  PDS Standards

      The MIDAS archive is based on the PDS Standard version 3.6 released in August 2003.

3.2.2  Time Standards

      All MIDAS timing information of archive data products that are mapped to binary tables (e.g.
      housekeeping data telemetry packets), is given in the Spacecraft Elapsed Time (referred to as
      OBT to prevent confusion with the SCET defined in the DDID) format as defined in [4], section
      2.7. The format used to represent the OBT is 4 bytes of unit seconds followed by 2 bytes of
      fractional seconds and is stored in the TM packet data field header. The OBT is set to zero at
      00:00:00 UTC on 1 Jan 2003. The instrument is synchronised with the S/C OBT on a regular
                                                                   Document No.      :  MID-IWF-TN-0087
                        ROSETTA-MIDAS to PSA                       Issue/Rev. No.    :  2.0
                        Interface Control Document                 Date              :  16 November 2017
                                                                   Page              :  25

      basis (typically every 30 minutes). In order to convert the OBT to UTC the NAIF SPICE software
      library is used. A more detailed description of the ROSETTA time standards is given in [8].
      To  represent    UTC  time values  in   archive data   products  represented   by ASCII   tables   (e.g.
      cantilever history data), the ASCII Time Code A format, defined by the Consultative Committee
      for Space Data Systems (CCSDS) is used. The ASCII Time Code A is a 24 character string of
      the   format  "YYYY-MM-DDThh:mm:ss.dddZ".        According    to the archive  plan   the trailing "Z" is
      omitted and no quotes are used
      In ground-based data sets the OBT reference is 00:00:00 UTC on 1 Jan 1970. Since the S/C
      clock   is   not  defined  for  ground    based   data,  there   is  no   relationship   between    the
      SPACECRAFT_CLOCK_START/STOP_COUNT                       keywords     (set   to    "N/A")    and     the
      START/STOP_TIME keywords (representing UTC) in the data labels. This has been taken into
      account by adding the NATIVE_START/STOP_TIME keywords to the data labels. The native
      start/stop time is given in seconds since 00:00:00 UTC on 1 Jan 1970 with leap seconds not
      taken into account (also referred to as UNIX time).

3.2.3  Reference Systems

      MIDAS Coordinate Systems
      The following reference systems are applicable to the MIDAS instrument:
               Unit Reference Frame: The basic co-ordinate system to be used for MIDAS at
               instrument level.
               AFM Reference Frame: The ARF system is used in the context of scanner operations
               and is fixed to the frame of the scanner table.
               Target Reference Frame: Defines the co-ordinate system on any individual target area
               (or target) on the collector.
      A detailed description of the MIDAS X/Y/Z reference systems can be found in the MIDAS Co-
      ordinate Systems document [9].

      J2000 System
      The   Earth   Mean  Equator  and  Equinox   of  Julian Date  2451545.0     (referred to  as the   J2000
      system) is the standard inertial reference frame. Some of the geometry keywords given in the
      data labels are expressed in J2000 coordinates (e.g. SC_SUN_POSITION_VECTOR).

3.2.4  Other Applicable Standards

      In order   to represent and  store the   images  in the  MIDAS    archive, the raw   data  images   are
      converted to BCR. The BCR-STM file format has been developed for easy exchange of SPM
      files   independent     of   the   instruments      used    (see    SPIP    Reference       Guide     at
      http://www.imagemet.com/WebHelp6/Default.htm).
      The header is 2048 bytes long and written in ASCII characters, which can be edited by a text
      editor. The first line identifies the format and should be:
               fileformat = bcrstm
      Additional parameters are defined as follows:
               xpixels and ypixels defines the number of pixels in the image
               xlength and ylength defines the scanning range in nm
                                                                 Document No.     : MID-IWF-TN-0087
                   ROSETTA-MIDAS to PSA                          Issue/Rev. No.   : 2.0
                   Interface Control Document                    Date             : 16 November 2017
                                                                 Page             : 26

             xunit, yunit and zunit units for the three axes (if not defined nm will be the default unit)
             current defines the tunneling current in nA (optional)
             bias defines the bias voltage in V (optional)
             starttime defines the starting time of the scanning (DD MM YY hh:mm:ss:hh) (optional)
             scanspeed is measured in nm/sec (optional)
             intelmode = 1 indicates that the data is written in little-endian 16-bit integers (LSB first;
             e.g. Intel x86 processors)
             intelmode = 0 indicates that the data is written in big-endian 16-bit integers (MSB first;
             e.g. Motorola 6800 processors)
             bit2nm is the scale factor for scaling the integer height data to nm
             xoffset and yoffset defines physical offset in nm (optional)
             voidpixels defines the value of void pixels (should be set equal to 32767; if omitted, the
             value is assumed to be 0)
     Comments can be written by starting the line with the characters `%' or `#'.
     It is possible to integrate new parameters as long the header size does not exceed 2048 bytes.
     The body of the BCR file contains xpixels*ypixels 16 bit signed integer data values.

3.3   Data Validation

     The following tools are used in order to validate the generated MIDAS data sets:
     PSA Volume Verifier (PVV)
     The PVV is a tool constructed by the PSA team to allow instrument teams from all of ESA's
     planetary missions to check their datasets before they are delivered to the PSA database for
     ingestion into the long-term archive. The tool allows a user to verify PDS compliance of a label,
     and validates all aspects of the data set structure / content prior to delivery to the PSA. The PVV
     is systematically used by the PSA team to check data sets as part of the ingestion process to the
     Planetary Science Archive (PSA).

     NASA PDS Tools
     The PDS Tools Package is the complete set of PDS Engineering Node supported tools. The
     following tools of the package are used:
             ddict - Extracts the data dictionary definition for every keyword used in a specified PDS
             label file, a specified list of PDS label Files, all of the labels in a directory, or all of the
             files on an entire volume. DDICT also lists those keywords that are not in the dictionary.
             kwvtool - This software creates a list of all keywords and their values found in a PDS
             label file or in a group of PDS label files.
             line - The LINE program analyzes each line in each file and reports on the status of
             certain PDS standards and the value associated with some of the PDS keywords.
             lvtool - This software checks PDS labels for compliance with the labeling standards
             established by the PDS for data product labels.
             NASAView - This program allows the user to display and examine PDS archive data
             products interactively.
                                                      Document No.       : MID-IWF-TN-0087
             ROSETTA-MIDAS to PSA                     Issue/Rev. No.     : 2.0
             Interface Control Document               Date               : 16 November 2017
                                                      Page               : 27

       table_check - The table checker program is a tool that checks PDS labels and its
       corresponding data files. It parses a label, checks for label and data errors (BINARY or
       ASCII files), and reports and summarizes its findings.
       tbtool - The PDS Table Browser is a utility for validating, browsing, and summarizing
       data that is organized by rows and columns and is described by a PDS label file.
MIDAS Data Set Browser
This software is used to display and validate the contents of an entire MIDAS archive data set
interactively. The software is entirely written in IDL and the source code files are included in the
DOCUMENT directory of the data sets (see chapter 5).
                                                                    Document No.       : MID-IWF-TN-0087
                       ROSETTA-MIDAS to PSA                         Issue/Rev. No.     : 2.0
                       Interface Control Document                   Date               : 16 November 2017
                                                                    Page               : 28

3.4   Content

      The   MIDAS    archive  will contain data   from important    laboratory measurements,          instrument
      checkout data generated in the interplanetary cruise phase and instrument data acquired in the
      close comet    environment,   as  well as  derived  or merged   instrument   data   e.g.    the cantilever
      utilisation history or the target exposure history.

3.4.1   Volume Set / Data Set

      The Rosetta archive is an online archive, where the data are delivered electronically. Thus there
      is no need to bundle several data sets into one volume, and one data set corresponds to one
      volume. A data set will include the data products as well as the secondary data, software and
      documentation     that completely  document     and   support the  use   of these      data products.  In
      general, the data products from the different instruments are contained in separate data sets,
      but  merged    data sets are  possible. Data  sets   may include   data  products   from    one  or more
      mission phases. Data products of different data processing levels are contained in separate data
      sets.

3.4.2   Directories

      The top-level structure of the ROOT directory of a typical MIDAS data archive volume (= data
      set)  corresponds   to chapter  19 of  the  PDS  Standards    Reference   [AD2]    and   is summarised
      below:

3.4.2.1   Root Directory

      .PDSVOLUME: Archive data file catalogue generated by PVV.
      AAREADME.TXT: This file describes the volume (= data set) as a whole. It gives an overview of
      the  contents   and  organisation of   the data  set, general  instructions  for   its use  and   contact
      information.
      ERRATA.TXT: This file describes errors and/or anomalies found in this and previous volumes (=
      data sets). As erroneous data sets should be corrected and delivered again, there is no need for
      this file.
      VOLDESC.CAT: This file contains the VOLUME object, which gives a high-level description of
      the contents of the volume (= data set).

3.4.2.2   Calibration Directory

      This directory contains the calibration files used in the processing of the raw data or needed to
      use the data products in the volume (= data set).
      CALINFO.TXT: Description of the contents of the CALIB directory.
      MIDCALIB.LBL: PDS label associated to the standard MIDAS calibration table.
      MIDCALIB.TAB: Standard MIDAS calibration table in PDS ASCII format.
                                                        Document No.    : MID-IWF-TN-0087
             ROSETTA-MIDAS to PSA                       Issue/Rev. No.  : 2.0
             Interface Control Document                 Date            : 16 November 2017
                                                        Page            : 29

The following table shows the standard calibration curves used for MIDAS housekeeping and
science data calibration:

 Reference  Calibration#Offset CalibrationFactorUnit Description
     1          0.0               1.0                One to one conversion
     2         -10.0          4.884005E-03     V     12 bit DAC set value [-10..10 V]
     3          0.0           3.051804E-04     V     16 bit ADC data [-10..10 V]
     4         -10.0          3.051804E-04     V     16 bit DAC set value [-10..10 V]
     5         -273.0         1.142998E-02    degC   Temperature [-273..101.52  C]
     6          0.0           9.170596E-04     V     +15 voltage monitor [-30..30 V]
     7          0.0           9.170596E-04     V     -15 voltage monitor [-30..30 V]
     8         100.0          4.272530E-03     V     Piezo HV voltage monitor [-40..240 V]
     9          0.0               1.0          um    Linear position set value [0..65535 um]
    10          0.0               0.1          um    XY stage positioning [0..6553.5 um]
    11          0.0           2.136263E-01     nm    XYZ position monitor [0..14000 nm]
    12          21.0              42.0         us    Pulse generator pulse width[21..2752491 us]
    13          0.0           5.493248E-03    deg    Cantilever phase signal [-180..180 deg]
    14          0.0           1.525902E-03     %     F-scan operating variables [0..100 %]
    15          0.0          4.577034E+01      Hz    Frequency high word [0..2999.56 kHz]
    16          0.0            6.984E-04       Hz    Frequency step/low word [0..45.77 Hz]
    17          0.0               1.0         sec    Time in seconds [0..65535]
    22       -0.065904          0.010293       A     MIDAS LCL 6A current
    23       -0.071692          0.010242       A     MIDAS LCL 6B current
    24       -1.845312          0.288204       W     MIDAS LCL 6A power
    25       -2.007376          0.286776       W     MIDAS LCL 6B power
    30          0.0               1.0                Bit pattern for image types
    31         800.0          -2.71276E-02     um    Approach LVDT position
    32         16.398            1.8221       mm     Linear stage LVDT position
    33          0.0           3.051804E-04     %     F-scan operating point [-100..100 %]
    34          0.0           6.103609E-05           Feature vector weight factor [0..4]
    35          0.0           1.525902E-05           Linear regression x/y factor
    40          0.0              0.164         nm    Z DAC set value (closed loop)
    41          0.0              3.814         nm    X DAC set value (open loop = default)
    42          0.0              1.389         nm    X DAC set value (closed loop)
    43          0.0              3.814         nm    Y DAC set value (open loop = default)
    44          0.0              1.389         nm    Y DAC set value (closed loop)
                                                                Document No.      : MID-IWF-TN-0087
                      ROSETTA-MIDAS to PSA                      Issue/Rev. No.    : 2.0
                      Interface Control Document                Date              : 16 November 2017
                                                                Page              : 30

3.4.2.3   Catalog Directory

     This directory contains the catalog object files for the entire volume (= data set):
     CATINFO.TXT: Description of the contents of the CATALOG directory.
     DATASET.CAT: PDS data set catalog information about the data set currently being submitted.
     INST.CAT: PDS instrument catalog information about the MIDAS instrument (likely to be the
     same in all deliveries, unless updates are needed).
     INSTHOST.CAT: PDS instrument host catalog information about the Rosetta spacecraft and the
     mounting relationship of the instruments within the spacecraft; provided by ESA.
     MISSION.CAT: PDS mission catalog information about the Rosetta mission; provided by ESA.
     REFERENCE.CAT: PDS reference catalog information about the every journal article, book or
     other published reference mentioned in the above catalog objects or their components.
     SOFTWARE.CAT: PDS software catalog information about the software submitted in the data
     set.
     TARGET.CAT: PDS target catalog information about the observation target, i.e. comet, asteroid,
     Earth or Mars; provided by ESA.

3.4.2.4   Index Directory

     This directory contains the index files summarising all data products in the volume (= data set)
     by mode, key instrument parameters or mission phase, and organised to facilitate finding the
     data of interest for a particular scientific question. Information about the observation geometry of
     the   data products  are also included   here, i.e. spacecraft position  and   attitude, illumination
     conditions  etc. Information that is not accurately  known  at the  time of delivery   and  thus will
     probably be updated later is stored in the index files rather than in the data product labels.
     INDXINFO.TXT: Description of the contents of the INDEX directory.

3.4.2.4.1  Dataset Index File, index.lbl and index.tab

     INDEX.LBL: Detached label for the index table INDEX.TAB. The INDEX_TABLE specific object
     is used to identify and describe the columns of the index table.
     INDEX.TAB: Index of the data set in tabular format.

3.4.2.4.2  Other Index Files

     None
                                                                   Document No.      : MID-IWF-TN-0087
                      ROSETTA-MIDAS to PSA                         Issue/Rev. No.    : 2.0
                      Interface Control Document                   Date              : 16 November 2017
                                                                   Page              : 31

3.4.2.5   Software Directory

     This   directory will not be  provided   in the   data  sets. Nevertheless,  the  source  codes   (IDL
     routines)  for  data  calibration, visualization and  analysis will be  provided  in the DOCUMENT
     directory.

3.4.2.6   Label Directory

     This directory contains PDS labels and includes files (referenced by a pointer in a PDS label)
     that are not packaged with the data products or in the data directory. For example, the format
     descriptions (columns) of the standard and extended housekeeping data products are located in
     this directory.
     LABINFO.TXT : Description of the contents of the LABEL directory.

3.4.2.7   Document Directory

     This directory provides documentation and supplementary and ancillary information to assist in
     understanding    and   using the   data products   in the volume    (= data set). The  documentation
     describes the MIDAS instrument as well as the MIDAS data sets and calibration. The MIDAS
     EAICD is included. According to the PDS standards the documents are present in ASCII format
     to  ensure  long-term   readability. Document    versions  in PDF   format  are also  provided in this
     directory.
     DOCINFO.TXT : Description of the contents of the DOCUMENT directory.

3.4.2.8   Extras Directory

     This directory will not be provided in the data sets.

3.4.2.9   Data Directory

     This directory contains the actual data such as images or tables. PDS labeled data files or data
     files with detached PDS label files are arranged in a logical subdirectory structure (see section
     3.1.4, Data Directory Naming Convention). Format specifications referred to in PDS labels are
     provided in the LABEL directory.

3.4.2.10   Browse, Geometry and Gazetter Directory

     These directories are not provided in the data sets.
                                                                           Document No.    : MID-IWF-TN-0087
                         ROSETTA-MIDAS to PSA                              Issue/Rev. No.  : 2.0
                         Interface Control Document                        Date            : 16 November 2017
                                                                           Page            : 32

4   Detailed Interface Specifications

4.1   Structure and Organization Overview

4.1.1  Data Processing Diagram

      The diagram below shows the MIDAS archive data set production principle:

                                                  MIDAS data set  production

               MIDAS                           Setup
           raw data archive(DDS data)                     Select  rawdata source(s)  e.g PC0 data (2 sessions):TLM_0508523_0508602_*.DATTLM_0510911_0510918_*.DAT

                                                        Define   global              e.g. volume start and stop time,
                                                      data set attributes            mission phase name and target, ...

            Data set profile
                                               Processing
                                                        Create emptydata set         creates data set directory structureand ingests data independent files(e.g. VOLDESC.CAT, format files, ...)
              ROSETTA
            SPICE kernel
              data pool                               For each session

                                                                                     ingests data labels and files for each
                                                          Ingest data                session within the selected raw data
             MIDAS archivedata set templates                files                    (session = set of raw data filesbelonging to the same observation)

                                                          End of loop

                                               Validation

             MIDAS archive                                 Cleanup                   removes unused format files and
                data set                                   data set                  labels as well as empty directories

                                                           Validate                  data validation with several tools
                                                           data set                  (e.g. PVV, NASA PDS Tools, ...)

                                                             End
                                                                  Document No.     :  MID-IWF-TN-0087
                      ROSETTA-MIDAS to PSA                        Issue/Rev. No.   :  2.0
                      Interface Control Document                  Date             :  16 November 2017
                                                                  Page             :  33

4.1.2  Data Product Preparation

      The preparation of the different data products is carried out in two different ways, depending on
      the data type:
              Plain TM packet copy: The archive data files are generated from the plain DDS raw
              data telemetry packets with the DDS header removed (e.g. housekeeping data files).
              Derived data products: At least one additional processing step is required in order to
              generate the data files (e.g. image data files).

      The following table gives an overview of the MIDAS data products and the associated type of
      data preparation (session = set of raw data files belonging to the same observation and/or time
      range):

      Data Type                       Mnemonic    Data Processing                           Table Type
      Housekeeping Data               HK1, HK2    plain TM copy; one file per session       BINARY
      Frequency Scan Data             FSC         plain TM copy; one file per scan          BINARY
      Single Point Approach Data      SPA         plain TM copy; one file per approach      BINARY
      Single Point Sampling Data      SPS         plain TM copy; one file per scan          BINARY
      Line Scan Data                  LIN         plain TM copy; one file per line          BINARY
      Image Scan Data                 IMG         converted to BCR format; one file         BINARY
                                                  per image and image data type
      Feature Vector Data             ROI         plain TM copy; one file per task          BINARY
      Event Data                      EVN         converted to ASCII; one file per          ASCII
                                                  session
      Cantilever Utilisation History  CAH         extracted from cumulative cantilever      ASCII
                                                  history file; one file per data set
      Target Utilisation History      TGH         extracted from cumulative target          ASCII
                                                  history file; one file per data set
                                                                Document No.     : MID-IWF-TN-0087
                      ROSETTA-MIDAS to PSA                      Issue/Rev. No.   : 2.0
                      Interface Control Document                Date             : 16 November 2017
                                                                Page             : 34

4.2   Data Sets, Definition and Content

4.2.1  Data Set Production

      According to the ROSETTA Archive Plan there is one separate data set per mission phase in
      the pre-cometary phase. The PDS formatted MIDAS data archives are delivered at the latest 6
      months after the end of the single mission phases.
      After arriving at the comet, a continuous  data flow  is anticipated (mission phases   approach,
      Lander delivery and relay, escort, extended mission), and the PDS formatted MIDAS data sets
      are delivered in 3-month intervals. The last proprietary, validation and archive preparation period
      of 6 months starts at the end of the Rosetta mission.
      The following data sets are provided (as defined in the ROSETTA Mission Calendar):

      Mission Phase              Start Date   End Date         Date Set ID
      GROUND                     2000-01-01   2004-03-01       data set selection ongoing
      LAUNCH                     2004-03-02   2004-03-04       no data
      COMMISSIONING              2004-03-052004-09-062004-06-062004-10-16RO-CAL-MIDAS-3-CVP-FULL-V2.0
      CRUISE 1                   2004-06-07   2004-09-05       no data
      EARTH SWING-BY 1           2004-10-17   2005-04-04       RO-X-MIDAS-3-EAR1-PC0-V2.0
      CRUISE 2                   2005-04-05   2006-07-28       RO-X-MIDAS-3-CR2-PC1-2-V2.0
      MARS SWING-BY              2006-07-29   2007-05-28       RO-X-MIDAS-3-MARS-PC3-5-V2.0
      CRUISE 3                   2007-05-29   2007-09-12       no data
      EARTH SWING-BY 2           2007-09-13   2008-01-27       RO-X-MIDAS-3-EAR2-PC6-7-V2.0
      CRUISE 4-1                 2008-01-28   2008-08-03       RO-X-MIDAS-3-CR4A-PC8-V2.0
      STEINS FLY-BY              2008-08-04   2008-10-05       no data
      CRUISE 4-2                 2008-10-06   2009-09-13       RO-X-MIDAS-3-CR4B-PC9-V2.0
      EARTH SWING-BY 3           2009-09-14   2009-12-13       RO-X-MIDAS-3-EAR3-PC10-V2.0
      CRUISE 5                   2009-12-14   2010-05-16       RO-X-MIDAS-3-CR5-PC12-V2.0
      LUTETIA FLY-BY             2010-05-17   2010-09-03       RO-A-MIDAS-3-AST2-LUTE-V2.0
      RENDEZVOUSMANEUVER 1       2010-09-04   2011-06-07       no data
      CRUISE 6                   2011-06-08   2014-01-20       no data
      PRELANDING                 2014-01-21   2014-11-18       RO-D-MIDAS-3-PRL-SAMPLES-V2.0
      COMET ESCORT 1             2014-11-19   2015-03-10       RO-C-MIDAS-3-ESC1-SAMPLES-V2.0
      COMET ESCORT 2             2015-03-11   2015-06-30       RO-C-MIDAS-3-ESC2-SAMPLES-V2.0
      COMET ESCORT 3             2015-07-01   2015-10-20       RO-C-MIDAS-3-ESC3-SAMPLES-V2.0
      COMET ESCORT 4             2015-10-21   2016-01-12       RO-C-MIDAS-3-ESC4-SAMPLES-V2.0
      ROSETTA EXTENS. 1          2016-01-13   2016-04-05       RO-C-MIDAS-3-EXT1-SAMPLES-V2.0
      ROSETTA EXTENS. 2          2016-04-06   2016-06-28       RO-C-MIDAS-3-EXT2-SAMPLES-V2.0
      ROSETTA EXTENS. 3          2016-06-29   2016-09-30       RO-C-MIDAS-3-EXT3-SAMPLES-V2.0
                                                                 Document No.     : MID-IWF-TN-0087
                     ROSETTA-MIDAS to PSA                        Issue/Rev. No.   : 2.0
                     Interface Control Document                  Date             : 16 November 2017
                                                                 Page             : 35

4.2.2  Instrument Mode Definition

      The MIDAS operational concept is based on tasks, rather than on modes. In order to perform a
      scientific observation, several tasks are executed one after the other. Therefore it is not very
      meaningful to describe a full observation (from instrument switch-on to switch-off) with a single
      mode identifier. Nevertheless, two rudimental instrument "modes" have been identified:

       INSTRUMENT_MODE_ID             INSTRUMENT_MODE_DESC
               NORMAL                 Data generated by S/W stored in on-board EEPROM.
          MODIFIED_NORMAL             Data generated by temporarily patched on-board S/W.

4.2.3  Data Quality Definition

      The following table lists the data quality identifiers and data quality   descriptions used in the
      MIDAS data labels:

          DATA_QUALITY_ID             DATA_QUALITY_DESC
                    -1                Data quality information is not supplied.
                    0                 Bad data.
                    1                 Use with caution.
                    2                 Data ok.

4.2.4  Geometry Information

      The following geometry keywords are used in the MIDAS data labels:

      Geometry Keyword                         Comment
      SC_SUN_POSITION_VECTOR                   "N/A" for ground based data sets.
      SC_TARGET_POSITION_VECTOR                "N/A" for ground based data sets.
      SC_TARGET_VELOCITY_VECTOR                "N/A" for ground based data sets.
      SPACECRAFT_ALTITUDE                      "N/A" for ground based and pre-comet data sets.
      SUB_SPACECRAFT_LATITUDE                  "N/A" for ground based and pre-comet data sets.
      SUB_SPACECRAFT_LONGITUDE                 "N/A" for ground based and pre-comet data sets.
                                                            Document No.     : MID-IWF-TN-0087
                     ROSETTA-MIDAS to PSA                   Issue/Rev. No.   : 2.0
                     Interface Control Document             Date             : 16 November 2017
                                                            Page             : 36

4.2.5  Mission Specific Keywords

      The following mission specific keywords (namespace ROSETTA) are used in the MIDAS data
      labels:

      Mission Specific Keyword        Data Values             Description
                                                              Position of the linear stage given
                                                              by the linear LVDT position
      MIDAS_LIN_STAGE_POS             -9.00 - +9.00 <V>       sensor. For a description of therelationship between tip number
                                                              and linear stage position see [9],
                                                              chapter 4.2.2.
                                      "DYNAMIC"
      MIDAS_SCANNING_MODE             "CONTACT"               Data acquisition mode.
                                      "MAGNETIC"
                                      "ZS:Z_SET_VAL"
                                      "AC:CANT_AC_MON"
                                      "AR:CANT_AC_RET"
                                      "PH:CANT_PH_MON"
                                      "DC:CANT_DC_MON"
                                      "XH:X_HV_MON"
                                      "YH:Y_HV_MON"
                                      "ZH:Z_HV_MON"           Image scans data type.
                                      "XP:X_POS_MON"
      MIDAS_SCAN_DATA_TYPE            "YP:Y_POS_MON"          A detailed description of the
                                      "ZP:Z_POS_MON"          different data types is given in
                                      "XE:X_ERR_MON"          chapter 2.5, "Image Scan Data".
                                      "YE:Y_ERR_MON"
                                      "ZE:Z_ERR_MON"
                                      "S1:DAQ_STATUS_1"
                                      "S2:DAQ_STATUS_2"
                                      "M1:CANT_AC_MAG1"
                                      "M2:CANT_AC_MAG2"
                                      "M3:CANT_AC_MAG3"
      MIDAS_SCAN_DIRECTION            {M,X,Y}M = MAIN_X, MAIN_YX = X_LTOH, X_HTOLY = Y_LTOH, Y_HTOLMain, X and Y image and linescan direction. LTOH indicatesscans from low to high piezocontrol voltages (default). HTOLdenotes the opposite direction.
                                                              Start coordinates (origin) of an
                                      (X,Y)MIDAS_SCAN_START_XYX = 0..65535Y = 0..65535image, line or single point scanrelative to the X/Y stage origin.The coordinates are given in DAC(digital-analogue converter) set
                                                              values.
                                      (X,Y)MIDAS_SCAN_STOP_XYX = 0..65535Y = 0..65535End coordinates of an image, line,or single point scan relative to theX/Y stage origin. The coordinatesare given in DAC set values.
                                                               Document No.        : MID-IWF-TN-0087
                     ROSETTA-MIDAS to PSA                      Issue/Rev. No.      : 2.0
                     Interface Control Document                Date                : 16 November 2017
                                                               Page                : 37

                                                                    Selected scan segment. The
                                                                    correlation between target number
      MIDAS_SEGMENT_NUMBER               0..1023                    and segment number is described
                                                                    in chapter 2.5, "Target Utilisation
                                                                    History".
                                         "TGZ02""TGX01"MIDAS_TARGET_NAME"TGT01""SILICON""SOLGEL"Name of scan target. TGZ02,TGX01 and TGT01 are used for(re-)calibration of the scannerhead (see chapter 2.5.3). Siliconand SOLGEL targets are used forduct collection.
                                                                    Selected scan target. The
                                                                    correlation between target number
      MIDAS_TARGET_NUMBER                1..64                      and segment number is described
                                                                    in chapter 2.5, "Target Utilisation
                                                                    History".
                                         "CALIBRATION"              Type of scan target. Plain silicon
      MIDAS_TARGET_TYPE                  "PLAIN SILICON"            and SOLGEL coated targets are
                                         "SOLGEL COATED"            used for dust collection.
                                                                    Selected scan cantilever. For a
                                                                    description of the relationship
      MIDAS_TIP_NUMBER                   1..16                      between tip number and linear
                                                                    stage position see [9], chapter
                                                                    4.2.2.

4.2.6  Astronomical Targets vs. MIDAS Targets

      The term "Target" is used both to refer to the MIDAS dust collection targets (also known as scan
      targets or facets) and the  astronomical  target which may    be a   planet, satellite, ring, region,
      feature, asteroid or comet.

      Astronomical Targets are referenced in the following context:
              Astronomical target attributes in PDS labels (TARGET_NAME, TARGET_TYPE,
              SC_TARGET_POSITION_VECTOR and SC_TARGET_VELOCITY_VECTOR)
              Catalog files INSTHOST.CAT, MISSION.CAT and TARGET.CAT
              DATA_SET_TARGET object in dataset catalog (DATASET.CAT)

      MIDAS Targets are referred to by
              Mission specific keywords in PDS labels (ROSETTA:MIDAS_TARGET_NAME,
              ROSETTA:MIDAS_TARGET_NUMBER and ROSETTA:MIDAS_TARGET_TYPE)
              Target column of image list provided in DATASET.CAT and targets in INST.CAT
              Event table in MIDAS target history files (/DATA/TGH*.LBL, TGH_STRUCTURE.FMT)
                                                                  Document No.         : MID-IWF-TN-0087
                      ROSETTA-MIDAS to PSA                        Issue/Rev. No.       : 2.0
                      Interface Control Document                  Date                 : 16 November 2017
                                                                  Page                 : 38

4.3   Data Product Design

4.3.1  Data Product Design - Standard Housekeeping Data

      The MIDAS standard housekeeping data files are binary tables containing the plain telemetry
      packets as retrieved from the DDS. Each data file has associated a detached PDS label with the
      same name as the data file it describes, but with the extension .LBL. The data file columns are
      defined in a separate format file referred to by the ^STRUCTURE keyword in the PDS labels:
             Data directory:    /DATA/HK1
             File naming:       HK1_yydddhh_yydddhh.DAT
             File structure:    /LABEL/HK1_STRUCTURE.FMT
      Parameters    having a  physical representation      can be  calibrated  by    applying the OFFSET,
      SCALING_FACTOR and UNIT keywords (defined in the related column object in the format file)
      to the raw value:
             physical_value = OFFSET + raw_value*SCALING_FACTOR [UNIT]

      A typical PDS label for a standard housekeeping data file is given below:

       PDS_VERSION_ID                        = PDS3
       LABEL_REVISION_NOTE                   = "<LABEL_REVISION_NOTE>"

       RECORD_TYPE                           = FIXED_LENGTH
       RECORD_BYTES                          = 56
       FILE_RECORDS                          = <FILE_RECORDS>

       DATA_SET_ID                           = "<DATA_SET_ID>"
       DATA_SET_NAME                         = "<DATA_SET_NAME>"

       PRODUCT_ID                            = "<PRODUCT_ID>"
       PRODUCT_VERSION_ID                    = "<PRODUCT_VERSION_ID>"
       PRODUCT_CREATION_TIME                 = <PRODUCT_CREATION_TIME>
       PRODUCT_TYPE                          = <PRODUCT_TYPE>
       PROCESSING_LEVEL_ID                   = <PROCESSING_LEVEL_ID>

       MISSION_ID                            = ROSETTA
       MISSION_NAME                          = "INTERNATIONAL    ROSETTA   MISSION"
       MISSION_PHASE_NAME                    = "<MISSION_PHASE_NAME>"

       INSTRUMENT_HOST_ID                    = <INSTRUMENT_HOST_ID>
       INSTRUMENT_HOST_NAME                  = "<INSTRUMENT_HOST_NAME>"
       INSTRUMENT_ID                         = <INSTRUMENT_ID>
       INSTRUMENT_NAME                       = "<INSTRUMENT_NAME>"
       INSTRUMENT_TYPE                       = "<INSTRUMENT_TYPE>"
       INSTRUMENT_MODE_ID                    = <INSTRUMENT_MODE_ID>
       INSTRUMENT_MODE_DESC                  = "<INSTRUMENT_MODE_DESC>"

       TARGET_NAME                           = "<TARGET_NAME>"
       TARGET_TYPE                           = "<TARGET_TYPE>"

       START_TIME                            = <START_TIME>
       STOP_TIME                             = <STOP_TIME>
       SPACECRAFT_CLOCK_START_COUNT          = "<START_COUNT>"
       SPACECRAFT_CLOCK_STOP_COUNT           = "<STOP_COUNT>"
       NATIVE_START_TIME                     = <NATIVE_START_TIME>
       NATIVE_STOP_TIME                      = <NATIVE_STOP_TIME>

       PRODUCER_ID                           = "<PRODUCER_ID>"
       PRODUCER_FULL_NAME                    = "<PRODUCER_FULL_NAME>"
       PRODUCER_INSTITUTION_NAME             = "<PRODUCER_INSTITUTION_NAME>"
                                                              Document No.      :  MID-IWF-TN-0087
                ROSETTA-MIDAS to PSA                          Issue/Rev. No.    :  2.0
                Interface Control Document                    Date              :  16 November 2017
                                                              Page              :  39

DATA_QUALITY_ID                       =  <DATA_QUALITY_ID>
DATA_QUALITY_DESC                     =  "<DATA_QUALITY_DESC>"

/* GEOMETRY   INFORMATION   */

SC_SUN_POSITION_VECTOR                =  <SC_SUN_POSITION_VECTOR>
SC_TARGET_POSITION_VECTOR             =  <SC_TARGET_POSITION_VECTOR>
SC_TARGET_VELOCITY_VECTOR             =  <SC_TARGET_VELOCITY_VECTOR>
SPACECRAFT_ALTITUDE                   =  <SPACECRAFT_ALTITUDE>
SUB_SPACECRAFT_LATITUDE               =  <SUB_SPACECRAFT_LATITUDE>
SUB_SPACECRAFT_LONGITUDE              =  <SUB_SPACECRAFT_LONGITUDE>

/* DATA  FILE  POINTER(S)   */

^HK1_TABLE                            =  "<FILE_NAME>"

/* DATA  OBJECT   DEFINITION(S)    */

OBJECT                                =  HK1_TABLE
    INTERCHANGE_FORMAT                =  BINARY
    ROWS                              =  <FILE_RECORDS>
    COLUMNS                           =  28
    ROW_BYTES                         =  56
    NAME                              =  "MIDAS  standard   HK"
    ^STRUCTURE                        =  "HK1_STRUCTURE.FMT"
END_OBJECT                            =  HK1_TABLE

END

The standard housekeeping data file structure is defined as follows:

    /*  HK1  FRAME  STRUCTURE   */

    OBJECT                            =  COLUMN
         NAME                         =  "PACKET_ID"
         DESCRIPTION                  =  "Telemetry   packet  identifier."
         DATA_TYPE                    =  MSB_UNSIGNED_INTEGER
         START_BYTE                   =  1
         BYTES                        =  2
    END_OBJECT                        =  COLUMN

    OBJECT                            =  COLUMN
         NAME                         =  "PACKET_SEQUENCE_CONTROL"
         DESCRIPTION                  =  "Telemetry   packet  sequence   counter."
         DATA_TYPE                    =  MSB_UNSIGNED_INTEGER
         START_BYTE                   =  3
         BYTES                        =  2
    END_OBJECT                        =  COLUMN

    OBJECT                            =  COLUMN
         NAME                         =  "PACKET_LENGTH"
         DESCRIPTION                  =  "Telemetry   packet  length."
         DATA_TYPE                    =  MSB_UNSIGNED_INTEGER
         START_BYTE                   =  5
         BYTES                        =  2
    END_OBJECT                        =  COLUMN

    OBJECT                            =  COLUMN
         NAME                         =  "PACKET_OBT_SECONDS"
         DESCRIPTION                  =  "S/C  clock  count  at  packet  generation."
         DATA_TYPE                    =  MSB_UNSIGNED_INTEGER
         START_BYTE                   =  7
         BYTES                        =  4
    END_OBJECT                        =  COLUMN

    OBJECT                            =  COLUMN
         NAME                         =  "PACKET_OBT_FRACTION"
         DESCRIPTION                  =  "Fractional   part  of  S/C clock   count."
         DATA_TYPE                    =  MSB_UNSIGNED_INTEGER
         START_BYTE                   =  11
                                                         Document No.       : MID-IWF-TN-0087
           ROSETTA-MIDAS to PSA                          Issue/Rev. No.     : 2.0
           Interface Control Document                    Date               : 16 November 2017
                                                         Page               : 40

    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PACKET_PUS_AND_CRC"
    DESCRIPTION                  = "Telemetry   packet   PUS-Version   and  CRC  flag."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 13
    BYTES                        = 1
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PACKET_TYPE"
    DESCRIPTION                  = "Telemetry   packet   type."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 14
    BYTES                        = 1
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PACKET_SUBTYPE"
    DESCRIPTION                  = "Telemetry   packet   sub-type."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 15
    BYTES                        = 1
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PACKET_PAD_FIELD"
    DESCRIPTION                  = "Telemetry   packet   padding  field."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 16
    BYTES                        = 1
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "STRUCTURE_ID"
    DESCRIPTION                  = "Telemetry   packet   structure   identifier."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 17
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "SOFTWARE_VERSION"
    DESCRIPTION                  = "On-board   software   version."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 19
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "INSTRUMENT_MODE"
    DESCRIPTION                  = "Instrument    mode  status  word."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 21
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "BASEPLATE_TEMPERATURE"
    DESCRIPTION                  = "AFM  base  plate  temperature    sensor  readout."
    DATA_TYPE                    = MSB_INTEGER
    START_BYTE                   = 23
    BYTES                        = 2
    OFFSET                       = 0.0
    SCALING_FACTOR               = 0.01143
    UNIT                         = KELVIN
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PREAMPLIFIER_TEMPERATURE"
    DESCRIPTION                  = "Cantilever    preamplifier   temperature    readout."
    DATA_TYPE                    = MSB_INTEGER
    START_BYTE                   = 25
                                                         Document No.       : MID-IWF-TN-0087
           ROSETTA-MIDAS to PSA                          Issue/Rev. No.     : 2.0
           Interface Control Document                    Date               : 16 November 2017
                                                         Page               : 41

    BYTES                        = 2
    OFFSET                       = 0.0
    SCALING_FACTOR               = 0.01143
    UNIT                         = KELVIN
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "CONVERTER_TEMPERATURE"
    DESCRIPTION                  = "Power   converter   temperature   readout."
    DATA_TYPE                    = MSB_INTEGER
    START_BYTE                   = 27
    BYTES                        = 2
    OFFSET                       = 0.0
    SCALING_FACTOR               = 0.01143
    UNIT                         = KELVIN
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "CSSC_XREF_TEMPERATURE"
    DESCRIPTION                  = "Capacitive    sensor  X reference   temperature."
    DATA_TYPE                    = MSB_INTEGER
    START_BYTE                   = 29
    BYTES                        = 2
    OFFSET                       = 0.0
    SCALING_FACTOR               = 0.01143
    UNIT                         = KELVIN
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "CSSC_YREF_TEMPERATURE"
    DESCRIPTION                  = "Capacitive    sensor  Y reference   temperature."
    DATA_TYPE                    = MSB_INTEGER
    START_BYTE                   = 31
    BYTES                        = 2
    OFFSET                       = 0.0
    SCALING_FACTOR               = 0.01143
    UNIT                         = KELVIN
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "INLET_TEMPERATURE"
    DESCRIPTION                  = "Temperature    measured   at the  dust  inlet."
    DATA_TYPE                    = MSB_INTEGER
    START_BYTE                   = 33
    BYTES                        = 2
    OFFSET                       = 0.0
    SCALING_FACTOR               = 0.01143
    UNIT                         = KELVIN
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "VOLTAGE_MONITOR_P05"
    DESCRIPTION                  = "+5V  voltage   monitor  readout."
    DATA_TYPE                    = MSB_INTEGER
    START_BYTE                   = 35
    BYTES                        = 2
    OFFSET                       = 0.0
    SCALING_FACTOR               = 0.00030518
    UNIT                         = V
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "VOLTAGE_MONITOR_P15"
    DESCRIPTION                  = "+15V  voltage   monitor   readout."
    DATA_TYPE                    = MSB_INTEGER
    START_BYTE                   = 37
    BYTES                        = 2
    OFFSET                       = 0.0
    SCALING_FACTOR               = 0.00091706
    UNIT                         = V
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "VOLTAGE_MONITOR_N15"
    DESCRIPTION                  = "-15V  voltage   monitor   readout."
                                                        Document No.        : MID-IWF-TN-0087
           ROSETTA-MIDAS to PSA                         Issue/Rev. No.      : 2.0
           Interface Control Document                   Date                : 16 November 2017
                                                        Page                : 42

    DATA_TYPE                    = MSB_INTEGER
    START_BYTE                   = 39
    BYTES                        = 2
    OFFSET                       = 0.0
    SCALING_FACTOR               = 0.00091706
    UNIT                         = V
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "DIGITAL_STATUS_1"
    DESCRIPTION                  = "Digital   lines  status   word  #1."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 41
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "DIGITAL_STATUS_2"
    DESCRIPTION                  = "Digital   lines  status   word  #2."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 43
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "DIGITAL_STATUS_3"
    DESCRIPTION                  = "Digital   lines  status   word  #3."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 45
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "DIGITAL_STATUS_4"
    DESCRIPTION                  = "Digital   lines  status   word  #4."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 47
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "DIGITAL_STATUS_5"
    DESCRIPTION                  = "Digital   lines  status   word  #5."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 49
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "ADC_OVERFLOW_FLAGS"
    DESCRIPTION                  = "Analog-Digital    Converter    overflow  flags."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 51
    BYTES                        = 4
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "CRC16_CHECKSUM"
    DESCRIPTION                  = "Telemetry   packet   checksum   (CRC  16)."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 55
    BYTES                        = 2
END_OBJECT                       = COLUMN
                                                                  Document No.         : MID-IWF-TN-0087
                      ROSETTA-MIDAS to PSA                        Issue/Rev. No.       : 2.0
                      Interface Control Document                  Date                 : 16 November 2017
                                                                  Page                 : 43

4.3.2  Data Product Design - Extended Housekeeping Data

      The MIDAS extended housekeeping data files are binary tables containing the plain telemetry
      packets as retrieved from the DDS. Each data file has associated a detached PDS label with the
      same name as the data file it describes, but with the extension .LBL. The data file columns are
      defined in a separate format file referred to by the ^STRUCTURE keyword in the PDS labels:
             Data directory:    /DATA/HK2
             File naming:       HK2_yydddhh_yydddhh.DAT
             File structure:    /LABEL/HK2_STRUCTURE.FMT
      Parameters    having a  physical representation      can be  calibrated  by    applying the OFFSET,
      SCALING_FACTOR and UNIT keywords (defined in the related column object in the format file)
      to the raw value:
             physical_value = OFFSET + raw_value*SCALING_FACTOR [UNIT]

      A typical PDS label for an extended housekeeping data file is given below:

       PDS_VERSION_ID                        = PDS3
       LABEL_REVISION_NOTE                   = "<LABEL_REVISION_NOTE>"

       RECORD_TYPE                           = FIXED_LENGTH
       RECORD_BYTES                          = 524
       FILE_RECORDS                          = <FILE_RECORDS>

       DATA_SET_ID                           = "<DATA_SET_ID>"
       DATA_SET_NAME                         = "<DATA_SET_NAME>"

       PRODUCT_ID                            = "<PRODUCT_ID>"
       PRODUCT_VERSION_ID                    = "<PRODUCT_VERSION_ID>"
       PRODUCT_CREATION_TIME                 = <PRODUCT_CREATION_TIME>
       PRODUCT_TYPE                          = <PRODUCT_TYPE>
       PROCESSING_LEVEL_ID                   = <PROCESSING_LEVEL_ID>

       MISSION_ID                            = ROSETTA
       MISSION_NAME                          = "INTERNATIONAL    ROSETTA   MISSION"
       MISSION_PHASE_NAME                    = "<MISSION_PHASE_NAME>"

       INSTRUMENT_HOST_ID                    = <INSTRUMENT_HOST_ID>
       INSTRUMENT_HOST_NAME                  = "<INSTRUMENT_HOST_NAME>"
       INSTRUMENT_ID                         = <INSTRUMENT_ID>
       INSTRUMENT_NAME                       = "<INSTRUMENT_NAME>"
       INSTRUMENT_TYPE                       = "<INSTRUMENT_TYPE>"
       INSTRUMENT_MODE_ID                    = <INSTRUMENT_MODE_ID>
       INSTRUMENT_MODE_DESC                  = "<INSTRUMENT_MODE_DESC>"

       TARGET_NAME                           = "<TARGET_NAME>"
       TARGET_TYPE                           = "<TARGET_TYPE>"

       START_TIME                            = <START_TIME>
       STOP_TIME                             = <STOP_TIME>
       SPACECRAFT_CLOCK_START_COUNT          = "<START_COUNT>"
       SPACECRAFT_CLOCK_STOP_COUNT           = "<STOP_COUNT>"
       NATIVE_START_TIME                     = <NATIVE_START_TIME>
       NATIVE_STOP_TIME                      = <NATIVE_STOP_TIME>

       PRODUCER_ID                           = "<PRODUCER_ID>"
       PRODUCER_FULL_NAME                    = "<PRODUCER_FULL_NAME>"
       PRODUCER_INSTITUTION_NAME             = "<PRODUCER_INSTITUTION_NAME>"

       DATA_QUALITY_ID                       = <DATA_QUALITY_ID>
       DATA_QUALITY_DESC                     = "<DATA_QUALITY_DESC>"
                                                              Document No.      :  MID-IWF-TN-0087
                ROSETTA-MIDAS to PSA                          Issue/Rev. No.    :  2.0
                Interface Control Document                    Date              :  16 November 2017
                                                              Page              :  44

/* GEOMETRY   INFORMATION   */

SC_SUN_POSITION_VECTOR                = <SC_SUN_POSITION_VECTOR>
SC_TARGET_POSITION_VECTOR             = <SC_TARGET_POSITION_VECTOR>
SC_TARGET_VELOCITY_VECTOR             = <SC_TARGET_VELOCITY_VECTOR>
SPACECRAFT_ALTITUDE                   = <SPACECRAFT_ALTITUDE>
SUB_SPACECRAFT_LATITUDE               = <SUB_SPACECRAFT_LATITUDE>
SUB_SPACECRAFT_LONGITUDE              = <SUB_SPACECRAFT_LONGITUDE>

/* DATA  FILE  POINTER(S)   */

^HK2_TABLE                            = "<FILE_NAME>"

/* DATA  OBJECT   DEFINITION(S)   */

OBJECT                                = HK2_TABLE
    INTERCHANGE_FORMAT                = BINARY
    ROWS                              = <FILE_RECORDS>
    COLUMNS                           = 259
    ROW_BYTES                         = 524
    NAME                              = "MIDAS   extended  HK"
    ^STRUCTURE                        = "HK2_STRUCTURE.FMT"
END_OBJECT                            = HK2_TABLE

END

The extended housekeeping data file structure is defined as follows:

    /*  HK2  FRAME  STRUCTURE   */

    OBJECT                            = COLUMN
         NAME                         = "PACKET_ID"
         DESCRIPTION                  = "Telemetry   packet   identifier."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 1
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "PACKET_SEQUENCE_CONTROL"
         DESCRIPTION                  = "Telemetry   packet   sequence   counter."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 3
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "PACKET_LENGTH"
         DESCRIPTION                  = "Telemetry   packet   length."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 5
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "PACKET_OBT_SECONDS"
         DESCRIPTION                  = "S/C  clock  count   at packet   generation."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 7
         BYTES                        = 4
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "PACKET_OBT_FRACTION"
         DESCRIPTION                  = "Fractional    part  of S/C  clock  count."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 11
         BYTES                        = 2
    END_OBJECT                        = COLUMN
                                                         Document No.       : MID-IWF-TN-0087
           ROSETTA-MIDAS to PSA                          Issue/Rev. No.     : 2.0
           Interface Control Document                    Date               : 16 November 2017
                                                         Page               : 45

OBJECT                           = COLUMN
    NAME                         = "PACKET_PUS_AND_CRC"
    DESCRIPTION                  = "Telemetry   packet   PUS-Version   and  CRC  flag."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 13
    BYTES                        = 1
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PACKET_TYPE"
    DESCRIPTION                  = "Telemetry   packet   type."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 14
    BYTES                        = 1
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PACKET_SUBTYPE"
    DESCRIPTION                  = "Telemetry   packet   sub-type."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 15
    BYTES                        = 1
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PACKET_PAD_FIELD"
    DESCRIPTION                  = "Telemetry   packet   padding  field."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 16
    BYTES                        = 1
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "STRUCTURE_ID"
    DESCRIPTION                  = "Telemetry   packet   structure   identifier."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 17
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "SOFTWARE_VERSION"
    DESCRIPTION                  = "On-board   software   version."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 19
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "U_CAN_RMS"
    DESCRIPTION                  = "Cantilever    AC signal   readout."
    DATA_TYPE                    = MSB_INTEGER
    START_BYTE                   = 21
    BYTES                        = 2
    OFFSET                       = 1.52590E-004
    SCALING_FACTOR               = 3.05180E-004
    UNIT                         = V
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "U_CAN_AMP_DC"
    DESCRIPTION                  = "Cantilever    DC signal   readout."
    DATA_TYPE                    = MSB_INTEGER
    START_BYTE                   = 23
    BYTES                        = 2
    OFFSET                       = 1.52590E-004
    SCALING_FACTOR               = 3.05180E-004
    UNIT                         = V
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "U_CAN_PHASE"
    DESCRIPTION                  = "Cantilever    phase  signal  readout."
    DATA_TYPE                    = MSB_INTEGER
    START_BYTE                   = 25
                                                        Document No.        : MID-IWF-TN-0087
           ROSETTA-MIDAS to PSA                         Issue/Rev. No.      : 2.0
           Interface Control Document                   Date                : 16 November 2017
                                                        Page                : 46

    BYTES                        = 2
    OFFSET                       = 2.74662E-003
    SCALING_FACTOR               = 5.49325E-003
    UNIT                         = deg
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "APP_POS_MON"
    DESCRIPTION                  = "Approach   position   sensor  readout."
    DATA_TYPE                    = MSB_INTEGER
    START_BYTE                   = 27
    BYTES                        = 2
    OFFSET                       = 1.52590E-004
    SCALING_FACTOR               = 3.05180E-004
    UNIT                         = V
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "LIN_POS_MON"
    DESCRIPTION                  = "Linear   stage  position   sensor  readout."
    DATA_TYPE                    = MSB_INTEGER
    START_BYTE                   = 29
    BYTES                        = 2
    OFFSET                       = 1.52590E-004
    SCALING_FACTOR               = 3.05180E-004
    UNIT                         = V
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "X_PR_OUT"
    DESCRIPTION                  = "X  piezo  control   loop  offset  error  readout."
    DATA_TYPE                    = MSB_INTEGER
    START_BYTE                   = 31
    BYTES                        = 2
    OFFSET                       = 1.52590E-004
    SCALING_FACTOR               = 3.05180E-004
    UNIT                         = V
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "Y_PR_OUT"
    DESCRIPTION                  = "Y  piezo  control   loop  offset  error  readout."
    DATA_TYPE                    = MSB_INTEGER
    START_BYTE                   = 33
    BYTES                        = 2
    OFFSET                       = 1.52590E-004
    SCALING_FACTOR               = 3.05180E-004
    UNIT                         = V
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "Z_PR_OUT"
    DESCRIPTION                  = "Z  piezo  control   loop  offset  error  readout."
    DATA_TYPE                    = MSB_INTEGER
    START_BYTE                   = 35
    BYTES                        = 2
    OFFSET                       = 1.52590E-004
    SCALING_FACTOR               = 3.05180E-004
    UNIT                         = V
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "XPIEZO_VSENS_OUT"
    DESCRIPTION                  = "X  piezo  high  voltage   monitor  readout."
    DATA_TYPE                    = MSB_INTEGER
    START_BYTE                   = 37
    BYTES                        = 2
    OFFSET                       = 1.00002E+002
    SCALING_FACTOR               = 4.27253E-003
    UNIT                         = V
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "YPIEZO_VSENS_OUT"
    DESCRIPTION                  = "Y  piezo  high  voltage   monitor  readout."
                                                              Document No.       : MID-IWF-TN-0087
                ROSETTA-MIDAS to PSA                          Issue/Rev. No.     : 2.0
                Interface Control Document                    Date               : 16 November 2017
                                                              Page               : 47

         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 39
         BYTES                        = 2
         OFFSET                       = 1.00002E+002
         SCALING_FACTOR               = 4.27253E-003
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "XPIEZO_POS"
         DESCRIPTION                  = "X  piezo  position   sensor  readout."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 41
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "YPIEZO_POS"
         DESCRIPTION                  = "Y  piezo  position   sensor  readout."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 43
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "ZPIEZO_POS"
         DESCRIPTION                  = "Z  piezo  position   sensor  readout."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 45
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "ZPIEZO_VSENS_OUT"
         DESCRIPTION                  = "Z  piezo  high  voltage  monitor   readout."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 47
         BYTES                        = 2
         OFFSET                       = 1.00002E+002
         SCALING_FACTOR               = 4.27253E-003
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "ABORT_FULLSCAN"
         DESCRIPTION                  = "Flag,   set if  ABORT  command   was sent  during   a  full
scan."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 49
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "ABORT_FUNCTION"
         DESCRIPTION                  = "Flag,   set if  ABORT  command   was sent   during  an active
task."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 51
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "ABORT_LINE"
         DESCRIPTION                  = "Flag,   set if  Z DAC  value  reached   its  lower  limit  (-
10V)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
                                                              Document No.       : MID-IWF-TN-0087
                ROSETTA-MIDAS to PSA                          Issue/Rev. No.     : 2.0
                Interface Control Document                    Date               : 16 November 2017
                                                              Page               : 48

         START_BYTE                   = 53
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "ABORT_POINT"
         DESCRIPTION                  = "Flag,   set if  Z DAC  value  reached   its  upper  limit
(+10V)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 55
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "AC_GAIN"
         DESCRIPTION                  = "Gain  level   for cantilever   AC  signal  amplifier   (0-7)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 57
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "APPR_BACKW_STARTED"
         DESCRIPTION                  = "Flag,   set if  backward   approach  task  is  active."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 59
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "APPR_FINISHED"
         DESCRIPTION                  = "Flag,   set if  segment  surface   was  detected   during
forward  approach."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 61
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "APPR_FINE_STEP"
         DESCRIPTION                  = "Flag,   set if  fine  steps  are  applied  during   approach."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 63
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "APPR_ON_MAX_POS"
         DESCRIPTION                  = "Flag,   set if  max.  position   was reached   during  an
approach  task."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 65
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "APPR_ON_MIN_POS"
         DESCRIPTION                  = "Flag,   set if  min.  position   was reached   during  an
approach  task."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 67
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "APPR_POSITION"
         DESCRIPTION                  = "Approach   position   sensor  readout   during  an  approach
task."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 69
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN
                                                             Document No.        : MID-IWF-TN-0087
                ROSETTA-MIDAS to PSA                         Issue/Rev. No.      : 2.0
                Interface Control Document                   Date                : 16 November 2017
                                                             Page                : 49

    OBJECT                            = COLUMN
         NAME                         = "APPR_POS_SET"
         DESCRIPTION                  = "Approach   position   set  value  for  next  forward  approach
step."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 71
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "APPR_STARTED"
         DESCRIPTION                  = "Flag,   set if  forward  approach   task  is  active."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 73
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "APPR_POS_ABS"
         DESCRIPTION                  = "Approach   position   set  value  for  absolute  approach
movement."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 75
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "APPR_DIR"
         DESCRIPTION                  = "Flag,   set if  approach   direction   is towards   surface."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 77
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "APPR_ABS_STARTED"
         DESCRIPTION                  = "Flag,   set if  absolute   approach  positioning    task  is
active."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 79
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "APPR_TIMO_CNT"
         DESCRIPTION                  = "Holds   remaining  seconds   until  approach   timeout
occurs."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 81
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "AVERAGE"
         DESCRIPTION                  = "Average   factor  for  Z strain   gauge  signal
measurement."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 83
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "CANTILEVER"
         DESCRIPTION                  = "Selected   cantilever   of  current  cantilever    block  (0-
7)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 85
         BYTES                        = 2
                                                              Document No.      :  MID-IWF-TN-0087
                ROSETTA-MIDAS to PSA                          Issue/Rev. No.    :  2.0
                Interface Control Document                    Date              :  16 November 2017
                                                              Page              :  50

    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "CANT_BLOCK"
         DESCRIPTION                  = "Number   of selected   cantilever   block  (1  or  2)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 87
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "CANT_SIGNAL"
         DESCRIPTION                  = "Current   cantilever   signal  measured   during   scan."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 89
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "CAL_X_CYCLE_STARTED"
         DESCRIPTION                  = "Flag,   set if  X position   sensor  calibration    task  has
started."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 91
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "CAL_X_CYCLE_FINISHED"
         DESCRIPTION                  = "Flag,   set if  X position   sensor  calibration    task  has
completed  successfully."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 93
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "CAL_Y_CYCLE_STARTED"
         DESCRIPTION                  = "Flag,   set if  Y position   sensor  calibration    task  has
started."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 95
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "CAL_Y_CYCLE_FINISHED"
         DESCRIPTION                  = "Flag,   set if  Y position   sensor  calibration    task  has
completed  successfully."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 97
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "CAP_SENS_EN"
         DESCRIPTION                  = "Flag,   set if  X/Y  position  sensor   control  is  enabled."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 99
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "CAL_CYCLES"
         DESCRIPTION                  = "X/Y  position   sensor  calibration    cycle  counter."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 101
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "CALIB_TIMO_CNT"
                                                              Document No.       : MID-IWF-TN-0087
                ROSETTA-MIDAS to PSA                          Issue/Rev. No.     : 2.0
                Interface Control Document                    Date               : 16 November 2017
                                                              Page               : 51

         DESCRIPTION                  = "Holds   remaining  seconds   until  X/Y  position   sensor
calibration   timeout  occurs."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 103
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "COR_TAB"
         DESCRIPTION                  = "Selected   correction   table  (0=norm   temp,  1=high   temp,
2=low  temp)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 105
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "CO_CMD"
         DESCRIPTION                  = "Last  checkout   (technical)   command   which  has  been
executed  on-board."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 107
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "CUR_LIN_POS"
         DESCRIPTION                  = "Current   linear  position   sensor  value   measured  during
linear  stage  movement."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 109
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "CYCLES"
         DESCRIPTION                  = "Holds   number  of Z  increments   and  decrements   during
single  point  scan."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 111
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "DATA_TYPE"
         DESCRIPTION                  = "Image   scan  data type  (0=z-topography,     1=z-error,
...)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 113
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "DC_GAIN"
         DESCRIPTION                  = "Gain  level   for cantilever   DC  signal  amplifier   (0-7)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 115
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "DC_PULSEWIDTH"
         DESCRIPTION                  = "Approach   DC  motor  pulse  width  set  value."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 117
         BYTES                        = 2
         OFFSET                       = 2.10000E+001
         SCALING_FACTOR               = 4.20000E+001
         UNIT                         = usec
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
                                                              Document No.        : MID-IWF-TN-0087
                ROSETTA-MIDAS to PSA                          Issue/Rev. No.      : 2.0
                Interface Control Document                    Date                : 16 November 2017
                                                              Page                : 52

         NAME                         = "DECR_APPR_POS"
         DESCRIPTION                  = "Flag,   set  if approach   advances   to next   position."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 119
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "DSCAN_RAND_AMPL"
         DESCRIPTION                  = "Dummy   scan  random  noise  amplitude   set  value."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 121
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "DELTA_APPR_POS"
         DESCRIPTION                  = "Approach   position   signal   decrement   used  in coarse
approach  steps."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 123
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "DELTA_OP_PERC"
         DESCRIPTION                  = "Allowed   deviation   from  cantilever   signal   operating
point  in %  of resonance   amplitude."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 125
         BYTES                        = 2
         OFFSET                       = 0.00000E+000
         SCALING_FACTOR               = 1.52590E-003
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "DELTA_OP_AMPL"
         DESCRIPTION                  = "Allowed   deviation   from  cantilever   signal   operating
point  (calculated)."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 127
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "DUMMY_FULL_SCAN"
         DESCRIPTION                  = "Flag,   set if  dummy  image   scan task   is active."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 129
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "EXC_LEV"
         DESCRIPTION                  = "Gain  level   for  cantilever   excitation   (0-7)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 131
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "DSCAN_SINE_AMPL"
         DESCRIPTION                  = "Dummy   scan  sine  amplitude   set value."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 133
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
                                                              Document No.       : MID-IWF-TN-0087
                ROSETTA-MIDAS to PSA                          Issue/Rev. No.     : 2.0
                Interface Control Document                    Date               : 16 November 2017
                                                              Page               : 53

         NAME                         = "DSCAN_ZERO_OFFS"
         DESCRIPTION                  = "Dummy   scan  zero offset   set  value."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 135
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "DSCAN_GRAD_SINE"
         DESCRIPTION                  = "Dummy   scan  X/Y gradient   and  sine  period  set  value."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 137
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "F_SCAN_NO_THRES"
         DESCRIPTION                  = "Flag,   set if  threshold   amplitude   has  not been  found
during  frequency   scan."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 139
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "F_SCAN_CYCLE"
         DESCRIPTION                  = "Current   scan  cycle  of  the automatic   frequency   scan
task."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 141
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "APPR_STUCK_CNT"
         DESCRIPTION                  = "Number   of times  the  approach   stuck  event   will  be
ignored."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 143
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "F_SCAN_STARTED"
         DESCRIPTION                  = "Flag,   set if  the  automatic   frequency   scan  task  is
active."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 145
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "F_SCAN_FINISHED"
         DESCRIPTION                  = "Flag,   set if  the  automatic   frequency   scan  task  has
completed."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 147
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "F_STEP"
         DESCRIPTION                  = "Nominal   frequency   scan  step  increment."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 149
         BYTES                        = 2
         OFFSET                       = 0.00000E+000
         SCALING_FACTOR               = 6.98253E-004
         UNIT                         = Hz
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "F_STEP_HI"
         DESCRIPTION                  = "Frequency   scan  step  increment   for  threshold
detection."
                                                              Document No.       :  MID-IWF-TN-0087
                ROSETTA-MIDAS to PSA                          Issue/Rev. No.     :  2.0
                Interface Control Document                    Date               :  16 November 2017
                                                              Page               :  54

         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 151
         BYTES                        = 2
         OFFSET                       = 0.00000E+000
         SCALING_FACTOR               = 6.98253E-004
         UNIT                         = Hz
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "FULLSCAN_STARTED"
         DESCRIPTION                  = "Flag,   set if  the  image  scan  task  is active."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 153
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "GAIN_STEP"
         DESCRIPTION                  = "Gain  control   increment/decrement     for  X/Y position
sensor  calibration."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 155
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "HK2_PERIOD"
         DESCRIPTION                  = "Extended   HK  report  update  period   in seconds."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 157
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "LAST_TC"
         DESCRIPTION                  = "Last  received   private   telecommand   (MSB=type,
LSB=subtype)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 159
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "LIN_MOVE_STARTED"
         DESCRIPTION                  = "Flag,   set if  a linear   stage  movement   task  is active."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 161
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "LIN_MOVE_FINISHED"
         DESCRIPTION                  = "Flag,   set if  a linear   stage  movement   task  has
completed."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 163
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "TEST_LIN_LVDT"
         DESCRIPTION                  = "Flag,   set if  linear  stage  position    sensor  is
evaluated  during   task."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 165
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "LINE_SCAN_CNT"
         DESCRIPTION                  = "Number   of scanned   image  lines  so  far."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 167
         BYTES                        = 2
    END_OBJECT                        = COLUMN
                                                              Document No.       :  MID-IWF-TN-0087
               ROSETTA-MIDAS to PSA                           Issue/Rev. No.     :  2.0
               Interface Control Document                     Date               :  16 November 2017
                                                              Page               :  55

    OBJECT                            = COLUMN
         NAME                         = "LINE_NUM_STEPS"
         DESCRIPTION                  = "Total   number  of image   lines  to be  scanned."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 169
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "LINESCAN_DONE"
         DESCRIPTION                  = "Flag,   set if  the  line  scan  task  has completed."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 171
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "LINESCAN_STARTED"
         DESCRIPTION                  = "Flag,   set if  the  line  scan  task  is active."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 173
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "LINMOVE_TIMO_CNT"
         DESCRIPTION                  = "Holds   remaining  seconds   until  linear   stage  timeout
occurs."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 175
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "LINMOVE_TIMO"
         DESCRIPTION                  = "Linear   stage  movement   timeout  set  value."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 177
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "MAIN_SCAN_CNT"
         DESCRIPTION                  = "Number   of scanned   pixels  in  main  scan  direction
(within  line)  so  far."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 179
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "MAIN_SCAN_DIR"
         DESCRIPTION                  = "Main  dummy/image/line     scan  direction   (0=X,  1=Y)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 181
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "MAIN_NUM_STEPS"
         DESCRIPTION                  = "Total   number  of pixels   in main  scan  direction."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 183
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "MAGN_RETRACT_DIST"
         DESCRIPTION                  = "Z  retraction   distance   for magnetic   mode."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 185
         BYTES                        = 2
    END_OBJECT                        = COLUMN
                                                              Document No.       : MID-IWF-TN-0087
                ROSETTA-MIDAS to PSA                          Issue/Rev. No.     : 2.0
                Interface Control Document                    Date               : 16 November 2017
                                                              Page               : 56

    OBJECT                            = COLUMN
         NAME                         = "MSUB_CYCLES"
         DESCRIPTION                  = "Maximum   number  of  scan  cycles  per  single_point()
function  call."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 187
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "MAX_CYCLES"
         DESCRIPTION                  = "Maximum   number  of  scan  cycles  allowed   for  a single
point."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 189
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "MAX_CAL_CYCLES"
         DESCRIPTION                  = "Maximum   number  of  X/Y  position  sensor   calibration
cycles."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 191
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "LAST_APPR_DIR"
         DESCRIPTION                  = "Approach   movement   direction   during  last  approach
task."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 193
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "NO_OF_FSCANS"
         DESCRIPTION                  = "Number   of frequency   sweep  cycles   for  the automatic
frequency  scan."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 195
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "OFFS_STEP"
         DESCRIPTION                  = "Offset   control  increment/decrement     for   X/Y  position
sensor  calibration."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 197
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "OP_POINT_PERC"
         DESCRIPTION                  = "Threshold   value  of  cantilever   signal   in %  of
resonance  amplitude   for  data  acquisition."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 199
         BYTES                        = 2
         OFFSET                       = 0.00000E+000
         SCALING_FACTOR               = 1.52590E-003
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "OP_POINT_AMPL"
         DESCRIPTION                  = "Threshold   value  of  cantilever   signal   for data
acquisition   (calculated)."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 201
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
                                                              Document No.       : MID-IWF-TN-0087
                ROSETTA-MIDAS to PSA                          Issue/Rev. No.     : 2.0
                Interface Control Document                    Date               : 16 November 2017
                                                              Page               : 57

    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "OP_UP"
         DESCRIPTION                  = "Cantilever    signal  threshold   value  upper  limit
(calculated)."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 203
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "OP_LO"
         DESCRIPTION                  = "Cantilever    signal  threshold   value  lower  limit
(calculated)."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 205
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "PERCENT_OP_AMPL"
         DESCRIPTION                  = "%  of resonance   amplitude   at  which  to  set the
operating  frequency   (+=right,   -=left)."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 207
         BYTES                        = 2
         OFFSET                       = 1.52590E-003
         SCALING_FACTOR               = 3.05180E-003
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "PARAMETER"
         DESCRIPTION                  = "Parameter   part  of  last  executed   parameter   command."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 209
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "PARAMETER_CMD"
         DESCRIPTION                  = "Command   code  of last  executed   parameter   command."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 211
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "PULSE_DELAY"
         DESCRIPTION                  = "Pulse   delay  mode  for linear   stage  motor  (0-3)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 213
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "PULSEWIDTH"
         DESCRIPTION                  = "Piezo   motor  driver  pulse  width."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 215
         BYTES                        = 2
         OFFSET                       = 2.10000E+001
         SCALING_FACTOR               = 4.20000E+001
         UNIT                         = usec
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "REF_SEARCH_STARTED"
                                                              Document No.        : MID-IWF-TN-0087
                 ROSETTA-MIDAS to PSA                         Issue/Rev. No.      : 2.0
                 Interface Control Document                   Date                : 16 November 2017
                                                              Page                : 58

         DESCRIPTION                  = "Flag,   set if  wheel  reference   point   search  has
started."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 217
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "RELAY_STATUS"
         DESCRIPTION                  = "Power   relay  status   flags."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 219
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "RESONANCE_AMPL"
         DESCRIPTION                  = "Cantilever    signal  amplitude   at  resonance   frequency."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 221
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "RETRACT_DIST"
         DESCRIPTION                  = "Z  retraction   before  advancing    to next  scan  position."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 223
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "SCAN_MODE"
         DESCRIPTION                  = "Scanning   mode  (0=dynamic,    1=contact,   2=magnetic)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 225
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "SCAN_ERROR_CNT"
         DESCRIPTION                  = "Holds   the number   of pixels   where  the  max.  number   of
scan cycles   was  exceeded."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 227
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "SEARCH_ALGOR"
         DESCRIPTION                  = "Cantilever    resonance  frequency    search  mode."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 229
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "SEND_CO_FR"
         DESCRIPTION                  = "Flag,   set if  checkout   frame  is  sent  periodically."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 231
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "DST_SELECT"
         DESCRIPTION                  = "Data  set  selection    for cleanup/transfer     (bit  15 =
oldest,  bit  14 =  newest)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 233
         BYTES                        = 2
    END_OBJECT                        = COLUMN
                                                              Document No.       :  MID-IWF-TN-0087
                ROSETTA-MIDAS to PSA                          Issue/Rev. No.     :  2.0
                Interface Control Document                    Date               :  16 November 2017
                                                              Page               :  59

    OBJECT                            = COLUMN
         NAME                         = "SEGMENT_PULSES"
         DESCRIPTION                  = "Wheel   encoder  ticks  for  segment   selection."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 235
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "SEGMENT_SEARCH_STARTED"
         DESCRIPTION                  = "Flag,   set if  segment  search   task  is active."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 237
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "SEGMENT_FOUND"
         DESCRIPTION                  = "Flag,   set if  the  wheel  segment  search   has  completed
successfully."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 239
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "SEGMENT_NO"
         DESCRIPTION                  = "Wheel   segment  selection   set  value  (0-1023)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 241
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "SET_LIN_POS"
         DESCRIPTION                  = "Linear   stage  position   sensor  value  for  absolute
positioning   (calculated)."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 243
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "SET_LIN_POS_ABS"
         DESCRIPTION                  = "Linear   stage  position   sensor  set  value  for  absolute
positioning."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 245
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "REGULAR_EXT_CODE"
         DESCRIPTION                  = "Flag,   set if  the  extended  program   code  area  is
entered  every  millisecond."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 247
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "SHUT_CLOSE_STARTED"
         DESCRIPTION                  = "Flag,   set if  the  shutter  closing   task  is active."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 249
         BYTES                        = 2
    END_OBJECT                        = COLUMN
                                                              Document No.       : MID-IWF-TN-0087
                ROSETTA-MIDAS to PSA                          Issue/Rev. No.     : 2.0
                Interface Control Document                    Date               : 16 November 2017
                                                              Page               : 60

    OBJECT                            = COLUMN
         NAME                         = "SHUT_OPEN_STARTED"
         DESCRIPTION                  = "Flag,   set if  the  shutter  opening   task  is active."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 251
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "SHUTTER_TIMO_CNT"
         DESCRIPTION                  = "Holds   remaining  seconds   until  a  shutter   movement
timeout  occurs."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 253
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "SINGLE_F_SCAN"
         DESCRIPTION                  = "Flag,   set if  the  single  frequency   scan  is  active."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 255
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "SURF_DETECTED"
         DESCRIPTION                  = "Flag,   set if  surface  was  detected   during  approach."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 257
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "TECH_MODE"
         DESCRIPTION                  = "Flag,   set if  technical   mode  commands   are enabled."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 259
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "TIMEOUTS"
         DESCRIPTION                  = "Timeout   status  flags."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 261
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "TIP_NO"
         DESCRIPTION                  = "Cantilever    selection  set  value  (0-15)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 263
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "U_MAX"
         DESCRIPTION                  = "Maximum   cantilever   signal  amplitude   detected   during
frequency  scan  so  far."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 265
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "VREF_ACC"
         DESCRIPTION                  = "X/Y  position   sensor  calibration    accuracy."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 267
         BYTES                        = 2
                                                              Document No.       : MID-IWF-TN-0087
                 ROSETTA-MIDAS to PSA                         Issue/Rev. No.     : 2.0
                 Interface Control Document                   Date               : 16 November 2017
                                                              Page               : 61

         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "VXREF1"
         DESCRIPTION                  = "X  position   sensor  reference   voltage  1."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 269
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "VXREF2"
         DESCRIPTION                  = "X  position   sensor  reference   voltage  2."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 271
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "VYREF1"
         DESCRIPTION                  = "Y  position   sensor  reference   voltage  1."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 273
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "VYREF2"
         DESCRIPTION                  = "Y  position   sensor  reference   voltage  2."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 275
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "WAIT_CYCLE"
         DESCRIPTION                  = "Flag,   set if  a wait  cycle  is  active."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 277
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "WAITING_TIME"
         DESCRIPTION                  = "Holds   number  of seconds   until  the  wait  cycle
completes."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 279
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "WAX_ACTUATOR"
         DESCRIPTION                  = "AFM  base   plate  lock mechanism   actuator   selection
(0=actuator   1, 1=  actuator   2)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 281
         BYTES                        = 2
    END_OBJECT                        = COLUMN
                                                               Document No.        : MID-IWF-TN-0087
               ROSETTA-MIDAS to PSA                            Issue/Rev. No.      : 2.0
               Interface Control Document                      Date                : 16 November 2017
                                                               Page                : 62

    OBJECT                            = COLUMN
         NAME                         = "WAXACT_TIMO_CNT"
         DESCRIPTION                  = "Holds   number  of  seconds   until  a base   plate  release
task timeout   occurs."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 283
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "WAXACT_STATUS"
         DESCRIPTION                  = "AFM  base   plate  lock  mechanism   actuator    heating  status
(1=main,  2=red,   4=extended)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 285
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "WAXACT_EXT_CNT"
         DESCRIPTION                  = "Holds   number  of  seconds   until  base   plate  actuator
extended  heating   cycle  completes."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 287
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "WAXACT_TIMO"
         DESCRIPTION                  = "AFM  base   plate  lock  mechanism   actuator    heating
timeout  set  value."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 289
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "WHEEL_TIMO_CNT"
         DESCRIPTION                  = "Holds   number  of  seconds   until  a wheel   segment
selection  timeout   occurs."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 291
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "X_ORIGIN"
         DESCRIPTION                  = "X  offset   of image  with  respect    to the  X/Y  table
origin."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 293
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "X_NUM_STEPS"
         DESCRIPTION                  = "Number   of scan   pixels  in  X direction    (n  times  32,
n=1-16)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 295
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "X_SCAN_DIRECTION"
         DESCRIPTION                  = "Flag,   indicates   X scan  direction   (0=low    to high  DAC
voltage,  1=  high  to low)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 297
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "X_STEP_SIZE"
         DESCRIPTION                  = "X  scan  step  set  value  in  DAC  units."
                                                               Document No.       : MID-IWF-TN-0087
               ROSETTA-MIDAS to PSA                            Issue/Rev. No.     : 2.0
               Interface Control Document                      Date               : 16 November 2017
                                                               Page               : 63

         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 299
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "XY_ACTUATOR"
         DESCRIPTION                  = "X/Y  table  lock   mechanism   actuator  selection    (0=  x-
actuator,  1=  y-actuator)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 301
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "XYACT_MAIN_STARTED"
         DESCRIPTION                  = "Flag,   set if  heating   cycle  of  the main   X or  Y
actuator  is  active."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 303
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "XYACT_RED_STARTED"
         DESCRIPTION                  = "Flag,   set if  heating   cycle  of  the redundant    X or  Y
actuator  is  active."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 305
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "XYACT_TIMO"
         DESCRIPTION                  = "X/Y  table  lock   mechanism   actuator  heating    timeout   set
value."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 307
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "XYACT_TIMO_CNT"
         DESCRIPTION                  = "Holds   number  of  seconds   until  an  X/Y table   release
timeout  occurs."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 309
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "Y_STEP_SIZE"
         DESCRIPTION                  = "Y  scan  step  set  value  in  DAC units."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 311
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "Y_ORIGIN"
         DESCRIPTION                  = "Y  offset   of image  with  respect   to the  X/Y   table
origin."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 313
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "Y_SCAN_DIRECTION"
         DESCRIPTION                  = "Flag,   indicates   Y scan  direction   (0=low   to  high  DAC
voltage,  1=  high  to low)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 315
         BYTES                        = 2
    END_OBJECT                        = COLUMN
                                                              Document No.       : MID-IWF-TN-0087
                ROSETTA-MIDAS to PSA                          Issue/Rev. No.     : 2.0
                Interface Control Document                    Date               : 16 November 2017
                                                              Page               : 64

    OBJECT                            = COLUMN
         NAME                         = "Y_NUM_STEPS"
         DESCRIPTION                  = "Number   of scan  pixels   in Y  direction   (n times  32,
n=1-16)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 317
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "Z_STEP_SIZE"
         DESCRIPTION                  = "Z  scan  step  set value   in DAC  units."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 319
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "HK2_OVFL_FLAGS"
         DESCRIPTION                  = "ADC  channel   overflow  flags."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 321
         BYTES                        = 4
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "DELTA_DC_CONTACT"
         DESCRIPTION                  = "Maximum   allowed  cantilever    DC value  change   during
surface  approach."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 325
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "CANT_SIGNAL_RETR"
         DESCRIPTION                  = "Cantilever    signal  at retracted   position   (magnetic
mode)."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 327
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "DST_INFO"
         DESCRIPTION                  = "Data  set  control   status  word  (0-7=ID,   8-11=status,
12-15=transfer   mode)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 329
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "LONG_Z"
         DESCRIPTION                  = "Last  Z  piezo  position   set value   during  scan."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 331
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "Z_GAIN"
         DESCRIPTION                  = "Gain  level   for Z  position  sensor   (strain  gauge)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 333
         BYTES                        = 2
    END_OBJECT                        = COLUMN
                                                              Document No.      : MID-IWF-TN-0087
                ROSETTA-MIDAS to PSA                          Issue/Rev. No.    : 2.0
                Interface Control Document                    Date              : 16 November 2017
                                                              Page              : 65

     OBJECT                           = COLUMN
         NAME                         = "GC_X"
         DESCRIPTION                  = "X/Y  position   sensor  X  gain  control  value."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 335
         BYTES                        = 2
     END_OBJECT                       = COLUMN

     OBJECT                           = COLUMN
         NAME                         = "GC_Y"
         DESCRIPTION                  = "X/Y  position    sensor Y  gain  control  value."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 337
         BYTES                        = 2
     END_OBJECT                       = COLUMN

     OBJECT                           = COLUMN
         NAME                         = "OFC_X"
         DESCRIPTION                  = "X/Y  position   sensor  X  offset  control   value."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 339
         BYTES                        = 2
     END_OBJECT                       = COLUMN

     OBJECT                           = COLUMN
         NAME                         = "OFC_Y"
         DESCRIPTION                  = "X/Y  position   sensor  Y  offset  control   value."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 341
         BYTES                        = 2
     END_OBJECT                       = COLUMN

     OBJECT                           = COLUMN
         NAME                         = "SCAN_ALGOR"
         DESCRIPTION                  = "Scan   algorithm   (1=window  detection,    2=p-controller,
else  threshold   detection)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 343
         BYTES                        = 2
     END_OBJECT                       = COLUMN

     OBJECT                           = COLUMN
         NAME                         = "FIRST_THRES_DET"
         DESCRIPTION                  = "Flag,   set  for first  threshold   detection   cycle   at
current  scan  location."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 345
         BYTES                        = 2
     END_OBJECT                       = COLUMN

     OBJECT                           = COLUMN
         NAME                         = "DUST_FLUX"
         DESCRIPTION                  = "GIADA   dust  flux  monitor  value  readout."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 347
         BYTES                        = 2
     END_OBJECT                       = COLUMN

     OBJECT                           = COLUMN
         NAME                         = "OP_POINT_PCONTROL"
         DESCRIPTION                  = "P-controller     (scanning)  operating   point  value
(calculated)."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 349
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
     END_OBJECT                       = COLUMN

     OBJECT                           = COLUMN
         NAME                         = "OP_POINT_PCONTR_PERC"
         DESCRIPTION                  = "P-controller     (scanning)  operating   point  set  value  in
% of  resonance   amplitude."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
                                                              Document No.       : MID-IWF-TN-0087
                ROSETTA-MIDAS to PSA                          Issue/Rev. No.     : 2.0
                Interface Control Document                    Date               : 16 November 2017
                                                              Page               : 66

         START_BYTE                   = 351
         BYTES                        = 2
         OFFSET                       = 0.00000E+000
         SCALING_FACTOR               = 1.52590E-003
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "PCONTR_KC"
         DESCRIPTION                  = "P-controller     (scanning)   gain  control  set  value."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 353
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "PCONTR_ACTIVE"
         DESCRIPTION                  = "Flag,   indicates   that  the P-controller    is  active
during  scanning."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 355
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "LAST_EVENT"
         DESCRIPTION                  = "Identifier    of last  generated   on-board   event."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 357
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "X_DAC_VAL"
         DESCRIPTION                  = "Last  DAC  value  applied   to  the X  piezo  of  the scanner
head."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 359
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "Y_DAC_VAL"
         DESCRIPTION                  = "Last  DAC  value  applied   to  the Y  piezo  of  the scanner
head."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 361
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "Z_DAC_VAL"
         DESCRIPTION                  = "Last  DAC  value  applied   to  the Z  piezo  of  the scanner
head."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 363
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "Z_SETTLE_TIME"
         DESCRIPTION                  = "Z  piezo  settling   time  in milliseconds    before
advancing  to  next  scan  position."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 365
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "XY_SETTLE_TIME"
         DESCRIPTION                  = "X/Y  piezo  settling   time  in  milliseconds   before
advancing  to  next  scan  position."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 367
         BYTES                        = 2
    END_OBJECT                        = COLUMN
                                                              Document No.       :  MID-IWF-TN-0087
                 ROSETTA-MIDAS to PSA                         Issue/Rev. No.     :  2.0
                 Interface Control Document                   Date               :  16 November 2017
                                                              Page               :  67

    OBJECT                            = COLUMN
         NAME                         = "DUST_FLUX_MIN"
         DESCRIPTION                  = "GIADA   dust  flux  monitor  lower  limit   (exposure   time
increases   when  exceeded)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 369
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "DUST_FLUX_MAX"
         DESCRIPTION                  = "GIADA   dust  flux  monitor  upper  limit   (exposure   time
decreases   when  exceeded)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 371
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "F_SCAN_MODE"
         DESCRIPTION                  = "Flag,   set  if threshold   detection   after  frequency   scan
is skipped."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 373
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "F_THRES_HI"
         DESCRIPTION                  = "Cantilever    operating   point  frequency   (high  word)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 375
         BYTES                        = 2
         OFFSET                       = 0.00000E+000
         SCALING_FACTOR               = 4.57703E+001
         UNIT                         = Hz
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "F_THRES_LO"
         DESCRIPTION                  = "Cantilever    operating   point  frequency   (low  word)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 377
         BYTES                        = 2
         OFFSET                       = 0.00000E+000
         SCALING_FACTOR               = 6.98253E-004
         UNIT                         = Hz
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "F_SYNTH"
         DESCRIPTION                  = "Last  output   value  of  frequency   synthesizer."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 379
         BYTES                        = 4
         OFFSET                       = 0.00000E+000
         SCALING_FACTOR               = 6.98253E-004
         UNIT                         = Hz
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "HK1_PERIOD"
         DESCRIPTION                  = "Standard   HK  report  update   period  in  seconds."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 383
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "F_HI"
         DESCRIPTION                  = "Last  output   value  of  frequency   synthesizer   (high
word)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 385
                                                              Document No.       : MID-IWF-TN-0087
                ROSETTA-MIDAS to PSA                          Issue/Rev. No.     : 2.0
                Interface Control Document                    Date               : 16 November 2017
                                                              Page               : 68

         BYTES                        = 2
         OFFSET                       = 0.00000E+000
         SCALING_FACTOR               = 4.57703E+001
         UNIT                         = Hz
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "F_LO"
         DESCRIPTION                  = "Last  output   value  of frequency   synthesizer    (low
word)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 387
         BYTES                        = 2
         OFFSET                       = 0.00000E+000
         SCALING_FACTOR               = 6.98253E-004
         UNIT                         = Hz
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "FRES_HI"
         DESCRIPTION                  = "Detected    cantilever   resonance  frequency   (high  word)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 389
         BYTES                        = 2
         OFFSET                       = 0.00000E+000
         SCALING_FACTOR               = 4.57703E+001
         UNIT                         = Hz
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "FRES_LO"
         DESCRIPTION                  = "Detected   cantilever   resonance   frequency   (low   word)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 391
         BYTES                        = 2
         OFFSET                       = 0.00000E+000
         SCALING_FACTOR               = 6.98253E-004
         UNIT                         = Hz
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "READ_ANALOG"
         DESCRIPTION                  = "Flag,   set if  analog  channels   readout   is performed
periodically"
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 393
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "F_SGL_START"
         DESCRIPTION                  = "Frequency   scan  start  value   of current   cycle."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 395
         BYTES                        = 4
         OFFSET                       = 0.00000E+000
         SCALING_FACTOR               = 6.98253E-004
         UNIT                         = Hz
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "F_INC"
         DESCRIPTION                  = "Frequency   scan  increment   value  between    cycles (256
times  F_STEP)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 399
         BYTES                        = 4
         OFFSET                       = 0.00000E+000
         SCALING_FACTOR               = 6.98253E-004
         UNIT                         = Hz
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "DC_AMPL_SET"
         DESCRIPTION                  = "DC  threshold   value  for  contact  mode  scanning."
                                                              Document No.        : MID-IWF-TN-0087
                ROSETTA-MIDAS to PSA                          Issue/Rev. No.      : 2.0
                Interface Control Document                    Date                : 16 November 2017
                                                              Page                : 69

         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 403
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "CHECK_DC_SIGNAL"
         DESCRIPTION                  = "Flag,   set if  checking   of the  cantilever    DC signal
during  approach   is enabled."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 405
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "U_CANT_DC_START"
         DESCRIPTION                  = "Cantilever    DC signal   value  at the  beginning    of the
coarse  approach."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 407
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "CONTACT"
         DESCRIPTION                  = "Flag,   set if   surface  contact   has occurred    during
coarse  approach."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 409
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "AUTO_F_ADJUST"
         DESCRIPTION                  = "Flag,   set if  frequency   adjustment   is  enabled   during
image  scan."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 411
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "WHEEL_COUNTS"
         DESCRIPTION                  = "Remaining   wheel   encoder  counts  until   segment   is
reached."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 413
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "PULSE_APPLIED"
         DESCRIPTION                  = "Flag,   set if  an  approach  pulse  has   been  applied."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 415
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "LAST_APPR_POSITION"
         DESCRIPTION                  = "Last  approach   position   used  for  checking   the  approach
movement."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 417
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN
                                                              Document No.      :  MID-IWF-TN-0087
                ROSETTA-MIDAS to PSA                          Issue/Rev. No.    :  2.0
                Interface Control Document                    Date              :  16 November 2017
                                                              Page              :  70

    OBJECT                            = COLUMN
         NAME                         = "MOVEMENT_CHECKED"
         DESCRIPTION                  = "Flag,   set if  the  approach  movement   has  been  checked."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 419
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "CUR_APPROACH_POS"
         DESCRIPTION                  = "Current   approach   position  used  for  checking   the
approach  movement."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 421
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "TEST_COUNT"
         DESCRIPTION                  = "Holds   number  of  milliseconds   until  approach   movement
is checked."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 423
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "APPR_TEST_COUNT"
         DESCRIPTION                  = "Approach   movement   test  interval   in milliseconds    (set
value)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 425
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "DELTA_OP_AMPL_DC"
         DESCRIPTION                  = "Contact   mode  operating   point  deviation   (calculated)."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 427
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "DELTA_OP_PERC_DC"
         DESCRIPTION                  = "Contact   mode  operating   point  deviation   in  % of
cantilever   DC set  value."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 429
         BYTES                        = 2
         OFFSET                       = 0.00000E+000
         SCALING_FACTOR               = 1.52590E-003
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "OP_UP_DC"
         DESCRIPTION                  = "Contact   mode  operating   point  amplitude   upper  limit."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 431
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "OP_LO_DC"
         DESCRIPTION                  = "Contact   mode  operating   point  amplitude   lower  limit."
                                                              Document No.       : MID-IWF-TN-0087
                ROSETTA-MIDAS to PSA                          Issue/Rev. No.     : 2.0
                Interface Control Document                    Date               : 16 November 2017
                                                              Page               : 71

         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 433
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "DELTA_APPR_LVDT"
         DESCRIPTION                  = "Minimum   approach   position  change   before  incrementing
the stuck   counter."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 435
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "APPR_POS_MAX"
         DESCRIPTION                  = "Approach   sensor   position  upper  limit   (set  value)."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 437
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "APPR_POS_MIN"
         DESCRIPTION                  = "Approach   sensor   position  lower  limit   (set  value)."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 439
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "FINE_ADJUSTMENT_STARTED"
         DESCRIPTION                  = "Flag,   set if  the  approach  fine  adjustment    has
started."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 441
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "TASK_ACTIVE"
         DESCRIPTION                  = "Flag,   set if  a task  is  active  (e.g.  scan)."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 443
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "APPR_NUM_PULSES"
         DESCRIPTION                  = "Number   of approach   pulses  to  apply  before   testing  the
approach  movement."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 445
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "CANT_HIRES_STARTED"
         DESCRIPTION                  = "Flag,   set if  the  cantilever   high  resolution   DAQ  task
is active."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 447
         BYTES                        = 2
                                                              Document No.       : MID-IWF-TN-0087
               ROSETTA-MIDAS to PSA                           Issue/Rev. No.     : 2.0
               Interface Control Document                     Date               : 16 November 2017
                                                              Page               : 72

    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "CANT_HIRES_TIME"
         DESCRIPTION                  = "Time  in  milliseconds   between   two  cantilever   high
resolution   measurements."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 449
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "CANT_HIRES_PKTS"
         DESCRIPTION                  = "Total   number  of cantilever    high  resolution   DAQ  data
packets."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 451
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "CANT_HIRES_TIME_CNT"
         DESCRIPTION                  = "Time  in  milliseconds   since   last  cantilever   high
resolution   measurement."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 453
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "CANT_HIRES_PKTS_CNT"
         DESCRIPTION                  = "Number   of cantilever   high  resolution    DAQ data  packets
generated  so  far."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 455
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "CAL_STATE"
         DESCRIPTION                  = "X/Y  position   sensor  calibration    task  status  word."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 457
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "SW_DATA_PAGE"
         DESCRIPTION                  = "Page  number   for S/W  backup/restore."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 459
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "SW_STATUS"
         DESCRIPTION                  = "S/W  encoding/decoding     task  status  word."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 461
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "SW_PAR_SET_ADDR"
         DESCRIPTION                  = "Last  S/W  parameter   address."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 463
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "SW_PAR_SET_VAL"
         DESCRIPTION                  = "Last  S/W  parameter   set  value."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 465
                                                         Document No.       : MID-IWF-TN-0087
           ROSETTA-MIDAS to PSA                          Issue/Rev. No.     : 2.0
           Interface Control Document                    Date               : 16 November 2017
                                                         Page               : 73

    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "SW_PAR_HK1_ADDR"
    DESCRIPTION                  = "Address   of  1st adjustable    HK parameter   readout."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 467
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "SW_PAR_HK2_ADDR"
    DESCRIPTION                  = "Address   of  2nd adjustable    HK parameter   readout."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 469
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "SW_PAR_HK3_ADDR"
    DESCRIPTION                  = "Address   of  3rd adjustable    HK parameter   readout."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 471
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "SW_PAR_HK4_ADDR"
    DESCRIPTION                  = "Address   of  4th adjustable    HK parameter   readout."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 473
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "SW_PAR_HK1_VAL"
    DESCRIPTION                  = "Value   of 1st  adjustable   HK  parameter   readout."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 475
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "SW_PAR_HK2_VAL"
    DESCRIPTION                  = "Value   of 2nd  adjustable   HK  parameter   readout."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 477
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "SW_PAR_HK3_VAL"
    DESCRIPTION                  = "Value   of 3rd  adjustable   HK  parameter   readout."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 479
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "SW_PAR_HK4_VAL"
    DESCRIPTION                  = "Value   of 4th  adjustable   HK  parameter   readout."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 481
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "FVECT_MODE"
    DESCRIPTION                  = "Feature   vector  calculation    mode."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 483
    BYTES                        = 2
END_OBJECT                       = COLUMN
                                                              Document No.       : MID-IWF-TN-0087
                ROSETTA-MIDAS to PSA                          Issue/Rev. No.     : 2.0
                Interface Control Document                    Date               : 16 November 2017
                                                              Page               : 74

    OBJECT                            = COLUMN
         NAME                         = "FVECT_LPERC"
         DESCRIPTION                  = "Feature   detection   threshold   value  in  percent   of
min/max  Z value."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 485
         BYTES                        = 2
         OFFSET                       = 0.00000E+000
         SCALING_FACTOR               = 1.52590E-003
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "FVECT_LEVEL"
         DESCRIPTION                  = "Calculated    feature  vector  threshold   value."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 487
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "FVECT_XMARGIN"
         DESCRIPTION                  = "Feature   vector  X  margin  (pixel)   with  respect   to
selected  image."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 489
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "FVECT_YMARGIN"
         DESCRIPTION                  = "Feature   vector  Y  margin  (pixel)   with  respect   to
selected  image."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 491
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "FVECT_STATUS"
         DESCRIPTION                  = "Feature   vector  calculation    status  word."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 493
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "FVECT_NUMPTS"
         DESCRIPTION                  = "Required   number  of  points  related   to  a feature    in
order  to be  selected."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 495
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "FVECT_AVG_Z"
         DESCRIPTION                  = "Required   average   height  over  Z level   for  a feature   in
order  to be  selected."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 497
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "FVECT_RATIO"
         DESCRIPTION                  = "Required   minimum   pixels/area   ratio  for  a  feature  in
order  to be  selected."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 499
         BYTES                        = 2
         OFFSET                       = 0.00000E+000
         SCALING_FACTOR               = 1.52590E-003
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
                                                              Document No.       : MID-IWF-TN-0087
                 ROSETTA-MIDAS to PSA                         Issue/Rev. No.     : 2.0
                 Interface Control Document                   Date               : 16 November 2017
                                                              Page               : 75

         NAME                         = "FVECT_ZFACTOR"
         DESCRIPTION                  = "Feature   vector  calculation    zoom  factor  in  % of
feature  size."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 501
         BYTES                        = 2
         OFFSET                       = 1.52590E-003
         SCALING_FACTOR               = 3.05180E-003
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "SC_ENABLED"
         DESCRIPTION                  = "Flag,   set if  science  data  transfer   is  enabled?"
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 503
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "POINT_READY"
         DESCRIPTION                  = "Flag,   set if  cantilever   signal  is  within  operating
point  range."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 505
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "IMAGE_POINT"
         DESCRIPTION                  = "Z  set  value  or AC  signal  difference   (magnetic    mode)
for last  DAQ  point."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 507
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "LIN_TIP_CENTER"
         DESCRIPTION                  = "Linear   LVDT  value  to center   the  currently   selected
tip within   the target."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 509
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "F_ADJUST_AMPL"
         DESCRIPTION                  = "Threshold   amplitude   for  automatic   f-adjusting    during
scans."
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 511
         BYTES                        = 2
         OFFSET                       = 1.52590E-004
         SCALING_FACTOR               = 3.05180E-004
         UNIT                         = V
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "HK2_SPARE_1"
         DESCRIPTION                  = "Extended   HK  report  spare  word  #1."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 513
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "HK2_SPARE_2"
         DESCRIPTION                  = "Extended   HK  report  spare  word  #2."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 515
         BYTES                        = 2
    END_OBJECT                        = COLUMN
                                                        Document No.       : MID-IWF-TN-0087
           ROSETTA-MIDAS to PSA                         Issue/Rev. No.     : 2.0
           Interface Control Document                   Date               : 16 November 2017
                                                        Page               : 76

OBJECT                           = COLUMN
    NAME                         = "HK2_SPARE_3"
    DESCRIPTION                  = "Extended   HK  report  spare  word  #3."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 517
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "HK2_SPARE_4"
    DESCRIPTION                  = "Extended   HK  report  spare  word  #4."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 519
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "HK2_SPARE_5"
    DESCRIPTION                  = "Extended   HK  report  spare  word  #5."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 521
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "HK2_FRAME_CS"
    DESCRIPTION                  = "Frame   checksum  (CRC16),   including   frame  header."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 523
    BYTES                        = 2
END_OBJECT                       = COLUMN
                                                                   Document No.        : MID-IWF-TN-0087
                      ROSETTA-MIDAS to PSA                         Issue/Rev. No.      : 2.0
                      Interface Control Document                   Date                : 16 November 2017
                                                                   Page                : 77

4.3.3  Data Product Design - Frequency Scan Data

      The MIDAS frequency scan data files are binary tables containing the plain telemetry packets as
      retrieved from  the DDS.  Each   data    file has associated a detached   PDS      label with the same
      name as the data file it describes, but with the extension .LBL. The data file columns are defined
      in a separate format file referred to by the ^STRUCTURE keyword in the PDS labels:
             Data directory:    /DATA/FSC
             File naming:       FSC_yydddhh_yydddhh_nnn_tt.DAT
             File structure:    /LABEL/FSC_PREFIX.FMT
      Parameters    having a  physical representation      can be  calibrated  by    applying  the  OFFSET,
      SCALING_FACTOR and UNIT keywords (defined in the related column object in the format file)
      to the raw value:
             physical_value = OFFSET + raw_value*SCALING_FACTOR [UNIT]
      A frequency scan comprises n (n=1...8) scan cycles of 256 samples each. This data can be
      mapped    to a frequency series  table    with  n rows and  1  column   having   256   items. Thus  the
      sampling parameter interval of the table object is 256 times the sampling parameter interval of
      the associated column object. The frequency range for a given scan is defined by the following
      keywords of the FREQUENCY_SERIES object:
             Start frequency:   MINIMUM_SAMPLING_PARAMETER
             Scan cycles:       ROWS   (total number of samples = 256*ROWS)
             Frequency step:    SAMPLING_PARAMETER_INTERVAL/256
             Frequency range: (256*ROWS          -   1)*SAMPLING_PARAMETER_INTERVAL/256

      A typical PDS label for a frequency scan data file is given below:

       PDS_VERSION_ID                        = PDS3
       LABEL_REVISION_NOTE                   = "<LABEL_REVISION_NOTE>"

       RECORD_TYPE                           = FIXED_LENGTH
       RECORD_BYTES                          = 576
       FILE_RECORDS                          = <FILE_RECORDS>

       DATA_SET_ID                           = "<DATA_SET_ID>"
       DATA_SET_NAME                         = "<DATA_SET_NAME>"

       PRODUCT_ID                            = "<PRODUCT_ID>"
       PRODUCT_VERSION_ID                    = "<PRODUCT_VERSION_ID>"
       PRODUCT_CREATION_TIME                 = <PRODUCT_CREATION_TIME>
       PRODUCT_TYPE                          = <PRODUCT_TYPE>
       PROCESSING_LEVEL_ID                   = <PROCESSING_LEVEL_ID>

       MISSION_ID                            = ROSETTA
       MISSION_NAME                          = "INTERNATIONAL    ROSETTA   MISSION"
       MISSION_PHASE_NAME                    = "<MISSION_PHASE_NAME>"

       INSTRUMENT_HOST_ID                    = <INSTRUMENT_HOST_ID>
       INSTRUMENT_HOST_NAME                  = "<INSTRUMENT_HOST_NAME>"
       INSTRUMENT_ID                         = <INSTRUMENT_ID>
       INSTRUMENT_NAME                       = "<INSTRUMENT_NAME>"
       INSTRUMENT_TYPE                       = "<INSTRUMENT_TYPE>"
       INSTRUMENT_MODE_ID                    = <INSTRUMENT_MODE_ID>
       INSTRUMENT_MODE_DESC                  = "<INSTRUMENT_MODE_DESC>"
                                                              Document No.       : MID-IWF-TN-0087
                ROSETTA-MIDAS to PSA                          Issue/Rev. No.     : 2.0
                Interface Control Document                    Date               : 16 November 2017
                                                              Page               : 78

TARGET_NAME                           = "<TARGET_NAME>"
TARGET_TYPE                           = "<TARGET_TYPE>"

START_TIME                            = <START_TIME>
STOP_TIME                             = <STOP_TIME>
SPACECRAFT_CLOCK_START_COUNT          = "<START_COUNT>"
SPACECRAFT_CLOCK_STOP_COUNT           = "<STOP_COUNT>"
NATIVE_START_TIME                     = <NATIVE_START_TIME>
NATIVE_STOP_TIME                      = <NATIVE_STOP_TIME>

PRODUCER_ID                           = "<PRODUCER_ID>"
PRODUCER_FULL_NAME                    = "<PRODUCER_FULL_NAME>"
PRODUCER_INSTITUTION_NAME             = "<PRODUCER_INSTITUTION_NAME>"

DATA_QUALITY_ID                       = <DATA_QUALITY_ID>
DATA_QUALITY_DESC                     = "<DATA_QUALITY_DESC>"

/* GEOMETRY   INFORMATION   */

SC_SUN_POSITION_VECTOR                = <SC_SUN_POSITION_VECTOR>
SC_TARGET_POSITION_VECTOR             = <SC_TARGET_POSITION_VECTOR>
SC_TARGET_VELOCITY_VECTOR             = <SC_TARGET_VELOCITY_VECTOR>
SPACECRAFT_ALTITUDE                   = <SPACECRAFT_ALTITUDE>
SUB_SPACECRAFT_LATITUDE               = <SUB_SPACECRAFT_LATITUDE>
SUB_SPACECRAFT_LONGITUDE              = <SUB_SPACECRAFT_LONGITUDE>

/* MISSION   SPECIFIC  KEYWORDS   */

ROSETTA:MIDAS_TIP_NUMBER              = <MIDAS_TIP_NUMBER>

/* DATA  FILE  POINTER(S)   */

^ROW_PREFIX_TABLE                     = "<FILE_NAME>"
^FREQUENCY_SERIES                     = "<FILE_NAME>"

/* DATA  OBJECT   DEFINITION(S)   */

OBJECT                                = ROW_PREFIX_TABLE
    NAME                              = PKT_HEADER
    INTERCHANGE_FORMAT                = BINARY
    ROWS                              = <FILE_RECORDS>
    COLUMNS                           = 23
    ROW_BYTES                         = 62
    ROW_SUFFIX_BYTES                  = 514
    DESCRIPTION                       = "Frequency    scan  header  table"
    ^STRUCTURE                        = "FSC_PREFIX.FMT"
END_OBJECT                            = ROW_PREFIX_TABLE

OBJECT                                = FREQUENCY_SERIES
    NAME                              = FREQUENCY_DATA
    INTERCHANGE_FORMAT                = BINARY
    ROWS                              = <FILE_RECORDS>
    COLUMNS                           = 1
    ROW_BYTES                         = 512
    ROW_PREFIX_BYTES                  = 62
    ROW_SUFFIX_BYTES                  = 2
    SAMPLING_PARAMETER_NAME           = FREQUENCY
    SAMPLING_PARAMETER_UNIT           = HERTZ
    SAMPLING_PARAMETER_INTERVAL       = <FSC_INTERVAL>           /*  time  between   rows  */
    MINIMUM_SAMPLING_PARAMETER        = <FSC_MINIMUM>
    DESCRIPTION                       = "<FSC_DESCRIPTION>"

    OBJECT                            = COLUMN
         NAME                         = DATA_SAMPLES
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 1
         BYTES                        = 512
         ITEMS                        = 256
         ITEM_BYTES                   = 2
         SAMPLING_PARAMETER_NAME      = FREQUENCY
         SAMPLING_PARAMETER_UNIT      = HERTZ
         SAMPLING_PARAMETER_INTERVAL       = <FSC_SAMPLING>          /*  time  between  samples   */

         SCALING_FACTOR               = 3.0518E-04
         OFFSET                       = 0.0
                                                              Document No.       : MID-IWF-TN-0087
               ROSETTA-MIDAS to PSA                           Issue/Rev. No.     : 2.0
               Interface Control Document                     Date               : 16 November 2017
                                                              Page               : 79

         DERIVED_MINIMUM              = 0.0
         DERIVED_MAXIMUM              = 10.0
    END_OBJECT                        = COLUMN
END_OBJECT                            = FREQUENCY_SERIES

END

The frequency scan row prefix structure is defined as follows:

    /*  FSC  PREFIX  STRUCTURE   */

    OBJECT                            = COLUMN
         NAME                         = "PACKET_ID"
         DESCRIPTION                  = "Telemetry   packet   identifier."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 1
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "PACKET_SEQUENCE_CONTROL"
         DESCRIPTION                  = "Telemetry   packet   sequence  counter."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 3
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "PACKET_LENGTH"
         DESCRIPTION                  = "Telemetry   packet   length."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 5
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "PACKET_OBT_SECONDS"
         DESCRIPTION                  = "S/C  clock  count  at  packet  generation."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 7
         BYTES                        = 4
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "PACKET_OBT_FRACTION"
         DESCRIPTION                  = "Fractional    part of  S/C  clock  count."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 11
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "PACKET_PUS_AND_CRC"
         DESCRIPTION                  = "Telemetry   packet   PUS-Version   and  CRC  flag."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 13
         BYTES                        = 1
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "PACKET_TYPE"
         DESCRIPTION                  = "Telemetry   packet   type."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 14
         BYTES                        = 1
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "PACKET_SUBTYPE"
         DESCRIPTION                  = "Telemetry   packet   sub-type."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
                                                         Document No.       : MID-IWF-TN-0087
           ROSETTA-MIDAS to PSA                          Issue/Rev. No.     : 2.0
           Interface Control Document                    Date               : 16 November 2017
                                                         Page               : 80

    START_BYTE                   = 15
    BYTES                        = 1
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PACKET_PAD_FIELD"
    DESCRIPTION                  = "Telemetry   packet   padding  field."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 16
    BYTES                        = 1
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "STRUCTURE_ID"
    DESCRIPTION                  = "Telemetry   packet   structure   identifier."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 17
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "SOFTWARE_VERSION"
    DESCRIPTION                  = "On-board   software    version."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 19
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "START_TIME"
    DESCRIPTION                  = "S/C  clock  count   at frequency   scan  start."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 21
    BYTES                        = 4
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "START_FREQUENCY"
    DESCRIPTION                  = "Start   value  of frequency   sweep."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 25
    BYTES                        = 4
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "FREQUENCY_STEP"
    DESCRIPTION                  = "Increment   value   of  frequency  sweep."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 29
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "AC_MAXIMUM"
    DESCRIPTION                  = "Detected   max.   cantilever  signal   amplitude
                                     (up to  the  current   scan cycle)."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 31
    BYTES                        = 2
    SCALING_FACTOR               = 3.0518E-04
    OFFSET                       = 0.0
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "FREQUENCY_AT_MAX"
    DESCRIPTION                  = "Frequency   where   the maximum   signal
                                     amplitude  was   detected."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 33
    BYTES                        = 4
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "NUM_SCANS"
    DESCRIPTION                  = "Total   number  of  frequency   scan  cycles."
                                                         Document No.       : MID-IWF-TN-0087
           ROSETTA-MIDAS to PSA                          Issue/Rev. No.     : 2.0
           Interface Control Document                    Date               : 16 November 2017
                                                         Page               : 81

    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 37
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "SCAN_CYCLE"
    DESCRIPTION                  = "Current   scan   cycle number."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 39
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "CANT_TIP_NUM"
    DESCRIPTION                  = "Selected   cantilever   [1-8]."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 41
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "CANT_BLK_NUM"
    DESCRIPTION                  = "Selected   cantilever   block   [1-2]."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 43
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "EXCITATION_LEVEL"
    DESCRIPTION                  = "Gain  level   of piezo-electric    actuator
                                     used for  cantilever   excitation    [0-7]."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 45
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "AC_GAIN_LEVEL"
    DESCRIPTION                  = "Gain  level   of cantilever   AC  signal
                                     amplifier  [0-7]."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 47
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "SPARE"
    DESCRIPTION                  = "Currently   not  used."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 49
    BYTES                        = 14
    ITEMS                        = 7
    ITEM_BYTES                   = 2
END_OBJECT                       = COLUMN
                                                                   Document No.        : MID-IWF-TN-0087
                      ROSETTA-MIDAS to PSA                         Issue/Rev. No.      : 2.0
                      Interface Control Document                   Date                : 16 November 2017
                                                                   Page                : 82

4.3.4  Data Product Design - Single Point Approach Data

      The MIDAS     single point approach      data files are binary tables containing   the  plain telemetry
      packets as retrieved from the DDS. Each data file has associated a detached PDS label with the
      same name as the data file it describes, but with the extension .LBL. The data file columns are
      defined in a separate format file referred to by the ^STRUCTURE keyword in the PDS labels:
             Data directory:     /DATA/SPA
             File naming:        SPA_yydddhh_yydddhh_nnn_tt.DAT
             File structure:     /LABEL/SPA_STRUCTURE.FMT
      Parameters    having  a physical representation       can be   calibrated by   applying the   OFFSET,
      SCALING_FACTOR and UNIT keywords (defined in the related column object in the format file)
      to the raw value:
             physical_value = OFFSET + raw_value*SCALING_FACTOR [UNIT]
      A single point approach scan data record comprises 4 data channels with up to n (n=1-256) data
      samples each. The actual number of data samples (valid for all channels) for a record is given in
      the NUM_SAMPLES column.

      A typical PDS label for a single point approach data file is given below:

       PDS_VERSION_ID                        = PDS3
       LABEL_REVISION_NOTE                   = "<LABEL_REVISION_NOTE>"

       RECORD_TYPE                           = FIXED_LENGTH
       RECORD_BYTES                          = 2096
       FILE_RECORDS                          = <FILE_RECORDS>

       DATA_SET_ID                           = "<DATA_SET_ID>"
       DATA_SET_NAME                         = "<DATA_SET_NAME>"

       PRODUCT_ID                            = "<PRODUCT_ID>"
       PRODUCT_VERSION_ID                    = "<PRODUCT_VERSION_ID>"
       PRODUCT_CREATION_TIME                 = <PRODUCT_CREATION_TIME>
       PRODUCT_TYPE                          = <PRODUCT_TYPE>
       PROCESSING_LEVEL_ID                   = <PROCESSING_LEVEL_ID>

       MISSION_ID                            = ROSETTA
       MISSION_NAME                          = "INTERNATIONAL    ROSETTA   MISSION"
       MISSION_PHASE_NAME                    = "<MISSION_PHASE_NAME>"

       INSTRUMENT_HOST_ID                    = <INSTRUMENT_HOST_ID>
       INSTRUMENT_HOST_NAME                  = "<INSTRUMENT_HOST_NAME>"
       INSTRUMENT_ID                         = <INSTRUMENT_ID>
       INSTRUMENT_NAME                       = "<INSTRUMENT_NAME>"
       INSTRUMENT_TYPE                       = "<INSTRUMENT_TYPE>"
       INSTRUMENT_MODE_ID                    = <INSTRUMENT_MODE_ID>
       INSTRUMENT_MODE_DESC                  = "<INSTRUMENT_MODE_DESC>"

       TARGET_NAME                           = "<TARGET_NAME>"
       TARGET_TYPE                           = "<TARGET_TYPE>"

       START_TIME                            = <START_TIME>
       STOP_TIME                             = <STOP_TIME>
       SPACECRAFT_CLOCK_START_COUNT          = "<START_COUNT>"
       SPACECRAFT_CLOCK_STOP_COUNT           = "<STOP_COUNT>"
       NATIVE_START_TIME                     = <NATIVE_START_TIME>
       NATIVE_STOP_TIME                      = <NATIVE_STOP_TIME>

       PRODUCER_ID                           = "<PRODUCER_ID>"
                                                              Document No.     :   MID-IWF-TN-0087
                ROSETTA-MIDAS to PSA                          Issue/Rev. No.   :   2.0
                Interface Control Document                    Date             :   16 November 2017
                                                              Page             :   83

PRODUCER_FULL_NAME                    =  "<PRODUCER_FULL_NAME>"
PRODUCER_INSTITUTION_NAME             =  "<PRODUCER_INSTITUTION_NAME>"

DATA_QUALITY_ID                       =  <DATA_QUALITY_ID>
DATA_QUALITY_DESC                     =  "<DATA_QUALITY_DESC>"

/* GEOMETRY   INFORMATION   */

SC_SUN_POSITION_VECTOR                =  <SC_SUN_POSITION_VECTOR>
SC_TARGET_POSITION_VECTOR             =  <SC_TARGET_POSITION_VECTOR>
SC_TARGET_VELOCITY_VECTOR             =  <SC_TARGET_VELOCITY_VECTOR>
SPACECRAFT_ALTITUDE                   =  <SPACECRAFT_ALTITUDE>
SUB_SPACECRAFT_LATITUDE               =  <SUB_SPACECRAFT_LATITUDE>
SUB_SPACECRAFT_LONGITUDE              =  <SUB_SPACECRAFT_LONGITUDE>

/* MISSION   SPECIFIC  KEYWORDS    */

ROSETTA:MIDAS_TIP_NUMBER              =  <MIDAS_TIP_NUMBER>
ROSETTA:MIDAS_TARGET_NUMBER           =  <MIDAS_TARGET_NUMBER>
ROSETTA:MIDAS_TARGET_TYPE             =  <MIDAS_TARGET_TYPE>
ROSETTA:MIDAS_TARGET_NAME             =  <MIDAS_TARGET_NAME>

ROSETTA:MIDAS_LIN_STAGE_POS           =  <MIDAS_LIN_STAGE_POS>
ROSETTA:MIDAS_SEGMENT_NUMBER          =  <MIDAS_SEGMENT_NUMBER>
ROSETTA:MIDAS_SCAN_START_XY           =  <MIDAS_SCAN_START_XY>
ROSETTA:MIDAS_SCAN_STOP_XY            =  <MIDAS_SCAN_STOP_XY>
ROSETTA:MIDAS_SCAN_DIRECTION          =  <MIDAS_SCAN_DIRECTION>

ROSETTA:MIDAS_SCANNING_MODE           =  <MIDAS_SCANNING_MODE>

/* DATA  FILE  POINTER(S)   */

^SPA_TABLE                            =  "<FILE_NAME>"

/* DATA  OBJECT   DEFINITION(S)   */

OBJECT                                =  SPA_TABLE
    INTERCHANGE_FORMAT                =  BINARY
    ROWS                              =  <FILE_RECORDS>
    COLUMNS                           =  27
    ROW_BYTES                         =  2096
    DESCRIPTION                       =  "MIDAS  scan  control   data"
    ^STRUCTURE                        =  "SPA_STRUCTURE.FMT"
END_OBJECT                            =  SPA_TABLE

END

The single point approach record structure is defined as follows:

    /*  SPA  FRAME  STRUCTURE   */

    OBJECT                            =  COLUMN
         NAME                         =  "PACKET_ID"
         DESCRIPTION                  =  "Telemetry   packet  identifier."
         DATA_TYPE                    =  MSB_UNSIGNED_INTEGER
         START_BYTE                   =  1
         BYTES                        =  2
    END_OBJECT                        =  COLUMN

    OBJECT                            =  COLUMN
         NAME                         =  "PACKET_SEQUENCE_CONTROL"
         DESCRIPTION                  =  "Telemetry   packet  sequence   counter."
         DATA_TYPE                    =  MSB_UNSIGNED_INTEGER
         START_BYTE                   =  3
         BYTES                        =  2
    END_OBJECT                        =  COLUMN

    OBJECT                            =  COLUMN
         NAME                         =  "PACKET_LENGTH"
         DESCRIPTION                  =  "Telemetry   packet  length."
         DATA_TYPE                    =  MSB_UNSIGNED_INTEGER
                                                         Document No.       : MID-IWF-TN-0087
           ROSETTA-MIDAS to PSA                          Issue/Rev. No.     : 2.0
           Interface Control Document                    Date               : 16 November 2017
                                                         Page               : 84

    START_BYTE                   = 5
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PACKET_OBT_SECONDS"
    DESCRIPTION                  = "S/C  clock  count   at packet   generation."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 7
    BYTES                        = 4
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PACKET_OBT_FRACTION"
    DESCRIPTION                  = "Fractional    part  of S/C  clock  count."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 11
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PACKET_PUS_AND_CRC"
    DESCRIPTION                  = "Telemetry   packet   PUS-Version   and  CRC  flag."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 13
    BYTES                        = 1
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PACKET_TYPE"
    DESCRIPTION                  = "Telemetry   packet   type."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 14
    BYTES                        = 1
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PACKET_SUBTYPE"
    DESCRIPTION                  = "Telemetry   packet   sub-type."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 15
    BYTES                        = 1
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PACKET_PAD_FIELD"
    DESCRIPTION                  = "Telemetry   packet   padding  field."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 16
    BYTES                        = 1
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "STRUCTURE_ID"
    DESCRIPTION                  = "Telemetry   packet   structure   identifier."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 17
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "SOFTWARE_VERSION"
    DESCRIPTION                  = "On-board   software    version."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 19
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "LINEAR_POS"
    DESCRIPTION                  = "Linear   stage  position   sensor  readout."
    DATA_TYPE                    = MSB_INTEGER
    START_BYTE                   = 21
    BYTES                        = 2
    OFFSET                       = 1.52590E-004
                                                          Document No.      : MID-IWF-TN-0087
           ROSETTA-MIDAS to PSA                           Issue/Rev. No.    : 2.0
           Interface Control Document                     Date              : 16 November 2017
                                                          Page              : 85

    SCALING_FACTOR               = 3.05180E-004
    UNIT                         = VOLT
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "WHEEL_POS"
    DESCRIPTION                  = "Current   wheel  position   (segment   number)."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 23
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "TIP_NUMBER"
    DESCRIPTION                  = "Number   of selected   tip."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 25
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "X_ORIGIN"
    DESCRIPTION                  = "Scan  origin   in X  direction   (DAC  units)."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 27
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "Y_ORIGIN"
    DESCRIPTION                  = "Scan  origin   in Y  direction   (DAC  units)."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 29
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "STEP_SIZE"
    DESCRIPTION                  = "Line  scan  step  size   (DAC  units)."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 31
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "NUM_STEPS"
    DESCRIPTION                  = "Number   of line  scan   steps  (pixels)."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 33
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "SCAN_MODE"
    DESCRIPTION                  = "Scanning    mode  for image   acquisition):
                                     Bit 0-7:   0=DYN[amic],   1=CON[tact],   2=MAG[netic],
                                     Bit    8:  line  scan direction   (0=std.,1=reverse),
                                     Bit  12:   main  scan direction   (0=X,1=Y)"
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 35
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "MAIN_SCAN_CNT"
    DESCRIPTION                  = "Current   main  scan  counter."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 37
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "NUM_SAMPLES"
    DESCRIPTION                  = "Total   number  of  measurements."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
                                                         Document No.      : MID-IWF-TN-0087
           ROSETTA-MIDAS to PSA                          Issue/Rev. No.    : 2.0
           Interface Control Document                    Date              : 16 November 2017
                                                         Page              : 86

    START_BYTE                   = 39
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "SPARE"
    DESCRIPTION                  = "Currently   not  used."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 41
    BYTES                        = 6
    ITEMS                        = 3
    ITEM_BYTES                   = 2
END_OBJECT                       = COLUMN

OBJECT                           = CONTAINER
    NAME                         = FRAME_STRUCTURE
    START_BYTE                   = 47
    BYTES                        = 8
    REPETITIONS                  = 256
    DESCRIPTION                  = "Container   for  the  256  repeating
         DAQ  samples  of  AC,  DC,  phase  and Z  position   signal."

    OBJECT                       = COLUMN
         NAME                    = "AC_SAMPLE"
         DESCRIPTION             = "Cantilever    AC signal   sample."
         DATA_TYPE               = MSB_INTEGER
         START_BYTE              = 1
         BYTES                   = 2
         SCALING_FACTOR          = 3.0518E-04
         OFFSET                  = 0.0
         UNIT                    = VOLT
         FORMAT                  = "F6.2"
         DERIVED_MINIMUM         = 0.0
         DERIVED_MAXIMUM         = 10.0
    END_OBJECT                   = COLUMN

    OBJECT                       = COLUMN
         NAME                    = "DC_SAMPLE"
         DESCRIPTION             = "Cantilever    DC signal   samples."
         DATA_TYPE               = MSB_INTEGER
         START_BYTE              = 3
         BYTES                   = 2
         SCALING_FACTOR          = 3.0518E-04
         OFFSET                  = 0.0
         UNIT                    = VOLT
         FORMAT                  = "F6.2"
         DERIVED_MINIMUM         = -10.0
         DERIVED_MAXIMUM         = +10.0
    END_OBJECT                   = COLUMN

    OBJECT                       = COLUMN
         NAME                    = "PHASE_SAMPLE"
         DESCRIPTION             = "Cantilever    phase  signal  samples."
         DATA_TYPE               = MSB_INTEGER
         START_BYTE              = 5
         BYTES                   = 2
         SCALING_FACTOR          = 5.4932E-03
         OFFSET                  = 0.0
         UNIT                    = DEGREE
         FORMAT                  = "F6.1"
         DERIVED_MINIMUM         = -180.0
         DERIVED_MAXIMUM         = +180.0
    END_OBJECT                   = COLUMN

    OBJECT                       = COLUMN
         NAME                    = "Z_POS_SAMPLE"
         DESCRIPTION             = "Z  piezo  position   monitor  (strain   gauge)."
         DATA_TYPE               = MSB_INTEGER
         START_BYTE              = 7
         BYTES                   = 2
         SCALING_FACTOR          = 3.0518E-04
         OFFSET                  = 0.0
         UNIT                    = VOLT
         FORMAT                  = "F6.2"
         DERIVED_MINIMUM         = -10.0
                                                        Document No.        : MID-IWF-TN-0087
           ROSETTA-MIDAS to PSA                         Issue/Rev. No.      : 2.0
           Interface Control Document                   Date                : 16 November 2017
                                                        Page                : 87

         DERIVED_MAXIMUM         = +10.0
    END_OBJECT                   = COLUMN

END_OBJECT                       = CONTAINER

OBJECT                           = COLUMN
    NAME                         = "CRC16_CHECKSUM"
    DESCRIPTION                  = "Telemetry   packet   checksum   (CRC  16)."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 2095
    BYTES                        = 2
END_OBJECT                       = COLUMN
                                                                    Document No.       : MID-IWF-TN-0087
                      ROSETTA-MIDAS to PSA                          Issue/Rev. No.     : 2.0
                      Interface Control Document                    Date               : 16 November 2017
                                                                    Page               : 88

4.3.5  Data Product Design - Single Point Sampling Data

      The MIDAS     single point sampling      data files are binary tables containing   the  plain telemetry
      packets as retrieved from the DDS. Each data file has associated a detached PDS label with the
      same name as the data file it describes, but with the extension .LBL. The data file columns are
      defined in a separate format file referred to by the ^STRUCTURE keyword in the PDS labels:
             Data directory:     /DATA/SPS
             File naming:        SPS_yydddhh_yydddhh_nnn_tt.DAT
             File structure:     /LABEL/SPS_PREFIX.FMT
      Parameters    having  a physical representation       can  be  calibrated by   applying the   OFFSET,
      SCALING_FACTOR and UNIT keywords (defined in the related column object in the format file)
      to the raw value:
             physical_value = OFFSET + raw_value*SCALING_FACTOR [UNIT]
      A single point sampling scan comprises n (n=1-65535) scan cycles with 4 data channels of 256
      samples each.   This  data  can be mapped       to  a time series  table  consisting of n rows   and 4
      interleaved columns with 256 items. Thus the sampling parameter interval of the table object is
      256 times the sampling parameter interval of the associated column object. The time range for a
      given scan is defined by the following keywords of the TIME_SERIES object:
             Scan cycles:        ROWS  (total number of samples per channel = 256*ROWS)
             Time step:          SAMPLING_PARAMETER_INTERVAL/256
             Time range:         (256*ROWS       -   1)*SAMPLING_PARAMETER_INTERVAL/256

      A typical PDS label for a single point sampling data file is given below:

       PDS_VERSION_ID                        = PDS3
       LABEL_REVISION_NOTE                   = "<LABEL_REVISION_NOTE>"

       RECORD_TYPE                           = FIXED_LENGTH
       RECORD_BYTES                          = 2096
       FILE_RECORDS                          = <FILE_RECORDS>

       DATA_SET_ID                           = "<DATA_SET_ID>"
       DATA_SET_NAME                         = "<DATA_SET_NAME>"

       PRODUCT_ID                            = "<PRODUCT_ID>"
       PRODUCT_VERSION_ID                    = "<PRODUCT_VERSION_ID>"
       PRODUCT_CREATION_TIME                 = <PRODUCT_CREATION_TIME>
       PRODUCT_TYPE                          = <PRODUCT_TYPE>
       PROCESSING_LEVEL_ID                   = <PROCESSING_LEVEL_ID>

       MISSION_ID                            = ROSETTA
       MISSION_NAME                          = "INTERNATIONAL    ROSETTA   MISSION"
       MISSION_PHASE_NAME                    = "<MISSION_PHASE_NAME>"

       INSTRUMENT_HOST_ID                    = <INSTRUMENT_HOST_ID>
       INSTRUMENT_HOST_NAME                  = "<INSTRUMENT_HOST_NAME>"
       INSTRUMENT_ID                         = <INSTRUMENT_ID>
       INSTRUMENT_NAME                       = "<INSTRUMENT_NAME>"
       INSTRUMENT_TYPE                       = "<INSTRUMENT_TYPE>"
       INSTRUMENT_MODE_ID                    = <INSTRUMENT_MODE_ID>
       INSTRUMENT_MODE_DESC                  = "<INSTRUMENT_MODE_DESC>"

       TARGET_NAME                           = "<TARGET_NAME>"
       TARGET_TYPE                           = "<TARGET_TYPE>"
                                                             Document No.       : MID-IWF-TN-0087
                ROSETTA-MIDAS to PSA                         Issue/Rev. No.     : 2.0
                Interface Control Document                   Date               : 16 November 2017
                                                             Page               : 89

START_TIME                            = <START_TIME>
STOP_TIME                             = <STOP_TIME>
SPACECRAFT_CLOCK_START_COUNT          = "<START_COUNT>"
SPACECRAFT_CLOCK_STOP_COUNT           = "<STOP_COUNT>"
NATIVE_START_TIME                     = <NATIVE_START_TIME>
NATIVE_STOP_TIME                      = <NATIVE_STOP_TIME>

PRODUCER_ID                           = "<PRODUCER_ID>"
PRODUCER_FULL_NAME                    = "<PRODUCER_FULL_NAME>"
PRODUCER_INSTITUTION_NAME             = "<PRODUCER_INSTITUTION_NAME>"

DATA_QUALITY_ID                       = <DATA_QUALITY_ID>
DATA_QUALITY_DESC                     = "<DATA_QUALITY_DESC>"

/* GEOMETRY   INFORMATION   */

SC_SUN_POSITION_VECTOR                = <SC_SUN_POSITION_VECTOR>
SC_TARGET_POSITION_VECTOR             = <SC_TARGET_POSITION_VECTOR>
SC_TARGET_VELOCITY_VECTOR             = <SC_TARGET_VELOCITY_VECTOR>
SPACECRAFT_ALTITUDE                   = <SPACECRAFT_ALTITUDE>
SUB_SPACECRAFT_LATITUDE               = <SUB_SPACECRAFT_LATITUDE>
SUB_SPACECRAFT_LONGITUDE              = <SUB_SPACECRAFT_LONGITUDE>

/* MISSION   SPECIFIC  KEYWORDS   */

ROSETTA:MIDAS_TIP_NUMBER              = <MIDAS_TIP_NUMBER>
ROSETTA:MIDAS_TARGET_NUMBER           = <MIDAS_TARGET_NUMBER>
ROSETTA:MIDAS_TARGET_TYPE             = <MIDAS_TARGET_TYPE>
ROSETTA:MIDAS_TARGET_NAME             = <MIDAS_TARGET_NAME>

ROSETTA:MIDAS_LIN_STAGE_POS           = <MIDAS_LIN_STAGE_POS>
ROSETTA:MIDAS_SEGMENT_NUMBER          = <MIDAS_SEGMENT_NUMBER>
ROSETTA:MIDAS_SCAN_START_XY           = <MIDAS_SCAN_START_XY>
ROSETTA:MIDAS_SCAN_STOP_XY            = <MIDAS_SCAN_STOP_XY>
ROSETTA:MIDAS_SCAN_DIRECTION          = <MIDAS_SCAN_DIRECTION>

ROSETTA:MIDAS_SCANNING_MODE           = <MIDAS_SCANNING_MODE>

/* DATA  FILE  POINTER(S)   */

^ROW_PREFIX_TABLE                     = "<FILE_NAME>"
^TIME_SERIES                          = "<FILE_NAME>"

/* DATA  OBJECT   DEFINITION(S)   */

OBJECT                                = ROW_PREFIX_TABLE
    NAME                              = PKT_HEADER
    INTERCHANGE_FORMAT                = BINARY
    ROWS                              = <FILE_RECORDS>
    COLUMNS                           = 22
    ROW_BYTES                         = 46
    ROW_SUFFIX_BYTES                  = 2050
    DESCRIPTION                       = "Control   data  prefix  table"
    ^STRUCTURE                        = "SPS_PREFIX.FMT"
END_OBJECT                            = ROW_PREFIX_TABLE

OBJECT                                = TIME_SERIES
    NAME                              = CONTROL_DATA
    INTERCHANGE_FORMAT                = BINARY
    ROWS                              = <FILE_RECORDS>
    COLUMNS                           = 4
    ROW_PREFIX_BYTES                  = 46
    ROW_BYTES                         = 2048
    ROW_SUFFIX_BYTES                  = 2
    SAMPLING_PARAMETER_NAME           = TIME
    SAMPLING_PARAMETER_UNIT           = SECONDS
    SAMPLING_PARAMETER_INTERVAL       = 3.6900E-1
    DESCRIPTION                       = "MIDAS   hi-res  sampling   data"

    OBJECT                            = COLUMN
         NAME                         = AC_SAMPLES
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 1
         BYTES                        = 2042
                                                            Document No.    : MID-IWF-TN-0087
                ROSETTA-MIDAS to PSA                        Issue/Rev. No.  : 2.0
                Interface Control Document                  Date            : 16 November 2017
                                                            Page            : 90

         ITEMS                        = 256
         ITEM_BYTES                   = 2
         ITEM_OFFSET                  = 8
         SAMPLING_PARAMETER_NAME      = TIME
         SAMPLING_PARAMETER_UNIT      = SECONDS
         SAMPLING_PARAMETER_INTERVAL       = 1.4414E-3
         SCALING_FACTOR               = 3.0518E-04
         OFFSET                       = 0.0
         DERIVED_MINIMUM              = 0.0
         DERIVED_MAXIMUM              = 10.0
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = DC_SAMPLES
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 3
         BYTES                        = 2042
         ITEMS                        = 256
         ITEM_BYTES                   = 2
         ITEM_OFFSET                  = 8
         SAMPLING_PARAMETER_NAME      = TIME
         SAMPLING_PARAMETER_UNIT      = SECONDS
         SAMPLING_PARAMETER_INTERVAL       = 1.4414E-3
         SCALING_FACTOR               = 3.0518E-04
         OFFSET                       = 0.0
         DERIVED_MINIMUM              = 0.0
         DERIVED_MAXIMUM              = 10.0
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = PHASE_SAMPLES
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 5
         BYTES                        = 2042
         ITEMS                        = 256
         ITEM_BYTES                   = 2
         ITEM_OFFSET                  = 8
         SAMPLING_PARAMETER_NAME      = TIME
         SAMPLING_PARAMETER_UNIT      = SECONDS
         SAMPLING_PARAMETER_INTERVAL       = 1.4414E-3
         SCALING_FACTOR               = 3.0518E-04
         OFFSET                       = 0.0
         DERIVED_MINIMUM              = 0.0
         DERIVED_MAXIMUM              = 10.0
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = Z_POS_SAMPLES
         DATA_TYPE                    = MSB_INTEGER
         START_BYTE                   = 7
         BYTES                        = 2042
         ITEMS                        = 256
         ITEM_BYTES                   = 2
         ITEM_OFFSET                  = 8
         SAMPLING_PARAMETER_NAME      = TIME
         SAMPLING_PARAMETER_UNIT      = SECONDS
         SAMPLING_PARAMETER_INTERVAL       = 1.4414E-3
         SCALING_FACTOR               = 3.0518E-04
         OFFSET                       = 0.0
         DERIVED_MINIMUM              = 0.0
         DERIVED_MAXIMUM              = 10.0
    END_OBJECT                        = COLUMN
END_OBJECT                            = TIME_SERIES

END

The single point sampling prefix structure is defined as follows:

    /*  SPS  PREFIX  STRUCTURE   */

    OBJECT                            = COLUMN
                                                         Document No.       : MID-IWF-TN-0087
           ROSETTA-MIDAS to PSA                          Issue/Rev. No.     : 2.0
           Interface Control Document                    Date               : 16 November 2017
                                                         Page               : 91

    NAME                         = "PACKET_ID"
    DESCRIPTION                  = "Telemetry   packet   identifier."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 1
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PACKET_SEQUENCE_CONTROL"
    DESCRIPTION                  = "Telemetry   packet   sequence   counter."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 3
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PACKET_LENGTH"
    DESCRIPTION                  = "Telemetry   packet   length."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 5
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PACKET_OBT_SECONDS"
    DESCRIPTION                  = "S/C  clock  count   at packet   generation."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 7
    BYTES                        = 4
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PACKET_OBT_FRACTION"
    DESCRIPTION                  = "Fractional    part  of S/C  clock  count."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 11
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PACKET_PUS_AND_CRC"
    DESCRIPTION                  = "Telemetry   packet   PUS-Version   and  CRC  flag."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 13
    BYTES                        = 1
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PACKET_TYPE"
    DESCRIPTION                  = "Telemetry   packet   type."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 14
    BYTES                        = 1
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PACKET_SUBTYPE"
    DESCRIPTION                  = "Telemetry   packet   sub-type."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 15
    BYTES                        = 1
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PACKET_PAD_FIELD"
    DESCRIPTION                  = "Telemetry   packet   padding  field."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 16
    BYTES                        = 1
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "STRUCTURE_ID"
    DESCRIPTION                  = "Telemetry   packet   structure   identifier."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
                                                          Document No.      : MID-IWF-TN-0087
           ROSETTA-MIDAS to PSA                           Issue/Rev. No.    : 2.0
           Interface Control Document                     Date              : 16 November 2017
                                                          Page              : 92

    START_BYTE                   = 17
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "SOFTWARE_VERSION"
    DESCRIPTION                  = "On-board    software  version."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 19
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "LINEAR_POS"
    DESCRIPTION                  = "Linear   stage  position   sensor  readout."
    DATA_TYPE                    = MSB_INTEGER
    START_BYTE                   = 21
    BYTES                        = 2
    OFFSET                       = 1.52590E-004
    SCALING_FACTOR               = 3.05180E-004
    UNIT                         = VOLT
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "WHEEL_POS"
    DESCRIPTION                  = "Current   wheel  position   (segment   number)."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 23
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "TIP_NUMBER"
    DESCRIPTION                  = "Number   of selected   tip."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 25
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "X_ORIGIN"
    DESCRIPTION                  = "Scan  origin   in X  direction   (DAC  units)."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 27
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "Y_ORIGIN"
    DESCRIPTION                  = "Scan  origin   in Y  direction   (DAC  units)."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 29
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "STEP_SIZE"
    DESCRIPTION                  = "Line  scan  step  size   (DAC  units)."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 31
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "NUM_STEPS"
    DESCRIPTION                  = "Number   of line  scan   steps  (pixels)."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 33
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "SCAN_MODE"
    DESCRIPTION                  = "Scanning    mode  for image   acquisition):
                                     Bit 0-7:   0=DYN[amic],   1=CON[tact],   2=MAG[netic],
                                                         Document No.     : MID-IWF-TN-0087
           ROSETTA-MIDAS to PSA                          Issue/Rev. No.   : 2.0
           Interface Control Document                    Date             : 16 November 2017
                                                         Page             : 93

                                     Bit    8: line  scan  direction   (0=std.,1=reverse),
                                     Bit  12:  main  scan  direction   (0=X,1=Y)"
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 35
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "MAIN_SCAN_CNT"
    DESCRIPTION                  = "Current   main  scan  counter."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 37
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "NUM_SAMPLES"
    DESCRIPTION                  = "Total   number  of  measurements."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 39
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "SPARE"
    DESCRIPTION                  = "Currently   not  used."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 41
    BYTES                        = 6
    ITEMS                        = 3
    ITEM_BYTES                   = 2
END_OBJECT                       = COLUMN
                                                                   Document No.        : MID-IWF-TN-0087
                      ROSETTA-MIDAS to PSA                         Issue/Rev. No.      : 2.0
                      Interface Control Document                   Date                : 16 November 2017
                                                                   Page                : 94

4.3.6  Data Product Design - Line Scan Data

      The MIDAS     line scan data files are     binary tables  containing the plain  telemetry   packets  as
      retrieved from  the DDS.  Each   data    file has associated  a detached   PDS     label with the same
      name as the data file it describes, but with the extension .LBL. The data file columns are defined
      in a separate format file referred to by the ^STRUCTURE keyword in the PDS labels:
             Data directory:    /DATA/LIN
             File naming:       LIN_yydddhh_yydddhh_nnn_tt.DAT
             File structure:    /LABEL/LIN_STRUCTURE.FMT
      Parameters    having  a physical representation      can  be  calibrated by    applying  the  OFFSET,
      SCALING_FACTOR and UNIT keywords (defined in the related column object in the format file)
      to the raw value:
             physical_value = OFFSET + raw_value*SCALING_FACTOR [UNIT]
      A line scan can have n (n=32, 64, .., 512) data points depending on the commanded number of
      pixels in the main scan direction. The line scan records have a fixed size, capable of holding the
      maximum number of 512 line scan data points. The actual number of data points for a given
      record can be determined from the NUM_STEPS column.
      Note: The   column   TIP_NUMBER     is    always  0  for telemetry  data generated    prior to  payload
      checkout #4 (corrected via S/W upload). Nevertheless, the proper value can be obtained from
      the mission specific keyword MIDAS_TIP_NUMBER which is included in the PDS label.

      A typical PDS label for a line scan data file is given below:

       PDS_VERSION_ID                        = PDS3
       LABEL_REVISION_NOTE                   = "<LABEL_REVISION_NOTE>"

       RECORD_TYPE                           = FIXED_LENGTH
       RECORD_BYTES                          = 1072
       FILE_RECORDS                          = <FILE_RECORDS>

       DATA_SET_ID                           = "<DATA_SET_ID>"
       DATA_SET_NAME                         = "<DATA_SET_NAME>"

       PRODUCT_ID                            = "<PRODUCT_ID>"
       PRODUCT_VERSION_ID                    = "<PRODUCT_VERSION_ID>"
       PRODUCT_CREATION_TIME                 = <PRODUCT_CREATION_TIME>
       PRODUCT_TYPE                          = <PRODUCT_TYPE>
       PROCESSING_LEVEL_ID                   = <PROCESSING_LEVEL_ID>

       MISSION_ID                            = ROSETTA
       MISSION_NAME                          = "INTERNATIONAL    ROSETTA   MISSION"
       MISSION_PHASE_NAME                    = "<MISSION_PHASE_NAME>"

       INSTRUMENT_HOST_ID                    = <INSTRUMENT_HOST_ID>
       INSTRUMENT_HOST_NAME                  = "<INSTRUMENT_HOST_NAME>"
       INSTRUMENT_ID                         = <INSTRUMENT_ID>
       INSTRUMENT_NAME                       = "<INSTRUMENT_NAME>"
       INSTRUMENT_TYPE                       = "<INSTRUMENT_TYPE>"
       INSTRUMENT_MODE_ID                    = <INSTRUMENT_MODE_ID>
       INSTRUMENT_MODE_DESC                  = "<INSTRUMENT_MODE_DESC>"

       TARGET_NAME                           = "<TARGET_NAME>"
       TARGET_TYPE                           = "<TARGET_TYPE>"

       START_TIME                            = <START_TIME>
       STOP_TIME                             = <STOP_TIME>
                                                              Document No.     :  MID-IWF-TN-0087
                ROSETTA-MIDAS to PSA                          Issue/Rev. No.   :  2.0
                Interface Control Document                    Date             :  16 November 2017
                                                              Page             :  95

SPACECRAFT_CLOCK_START_COUNT          = "<START_COUNT>"
SPACECRAFT_CLOCK_STOP_COUNT           = "<STOP_COUNT>"
NATIVE_START_TIME                     = <NATIVE_START_TIME>
NATIVE_STOP_TIME                      = <NATIVE_STOP_TIME>

PRODUCER_ID                           = "<PRODUCER_ID>"
PRODUCER_FULL_NAME                    = "<PRODUCER_FULL_NAME>"
PRODUCER_INSTITUTION_NAME             = "<PRODUCER_INSTITUTION_NAME>"

DATA_QUALITY_ID                       = <DATA_QUALITY_ID>
DATA_QUALITY_DESC                     = "<DATA_QUALITY_DESC>"

/* GEOMETRY   INFORMATION   */

SC_SUN_POSITION_VECTOR                = <SC_SUN_POSITION_VECTOR>
SC_TARGET_POSITION_VECTOR             = <SC_TARGET_POSITION_VECTOR>
SC_TARGET_VELOCITY_VECTOR             = <SC_TARGET_VELOCITY_VECTOR>
SPACECRAFT_ALTITUDE                   = <SPACECRAFT_ALTITUDE>
SUB_SPACECRAFT_LATITUDE               = <SUB_SPACECRAFT_LATITUDE>
SUB_SPACECRAFT_LONGITUDE              = <SUB_SPACECRAFT_LONGITUDE>

/* MISSION   SPECIFIC  KEYWORDS   */

ROSETTA:MIDAS_TIP_NUMBER              = <MIDAS_TIP_NUMBER>
ROSETTA:MIDAS_TARGET_NUMBER           = <MIDAS_TARGET_NUMBER>
ROSETTA:MIDAS_TARGET_TYPE             = <MIDAS_TARGET_TYPE>
ROSETTA:MIDAS_TARGET_NAME             = <MIDAS_TARGET_NAME>

ROSETTA:MIDAS_LIN_STAGE_POS           = <MIDAS_LIN_STAGE_POS>
ROSETTA:MIDAS_SEGMENT_NUMBER          = <MIDAS_SEGMENT_NUMBER>
ROSETTA:MIDAS_SCAN_START_XY           = <MIDAS_SCAN_START_XY>
ROSETTA:MIDAS_SCAN_STOP_XY            = <MIDAS_SCAN_STOP_XY>
ROSETTA:MIDAS_SCAN_DIRECTION          = <MIDAS_SCAN_DIRECTION>

ROSETTA:MIDAS_SCANNING_MODE           = <MIDAS_SCANNING_MODE>

/* DATA  FILE  POINTER(S)   */

^LINE_SCAN_TABLE                      = "<FILE_NAME>"

/* DATA  OBJECT   DEFINITION(S)   */

OBJECT                                = LINE_SCAN_TABLE
    INTERCHANGE_FORMAT                = BINARY
    ROWS                              = <FILE_RECORDS>
    COLUMNS                           = 23
    ROW_BYTES                         = 1072
    DESCRIPTION                       = "MIDAS   line  scan  data"
    ^STRUCTURE                        = "LIN_STRUCTURE.FMT"
END_OBJECT                            = LINE_SCAN_TABLE

END

The line scan data structure is defined as follows:

    /*  LINE  SCAN  FRAME  STRUCTURE   */

    OBJECT                            = COLUMN
         NAME                         = "PACKET_ID"
         DESCRIPTION                  = "Telemetry   packet   identifier."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 1
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "PACKET_SEQUENCE_CONTROL"
         DESCRIPTION                  = "Telemetry   packet   sequence  counter."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 3
         BYTES                        = 2
                                                         Document No.       : MID-IWF-TN-0087
           ROSETTA-MIDAS to PSA                          Issue/Rev. No.     : 2.0
           Interface Control Document                    Date               : 16 November 2017
                                                         Page               : 96

END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PACKET_LENGTH"
    DESCRIPTION                  = "Telemetry   packet   length."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 5
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PACKET_OBT_SECONDS"
    DESCRIPTION                  = "S/C  clock  count   at packet   generation."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 7
    BYTES                        = 4
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PACKET_OBT_FRACTION"
    DESCRIPTION                  = "Fractional    part  of S/C  clock  count."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 11
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PACKET_PUS_AND_CRC"
    DESCRIPTION                  = "Telemetry   packet   PUS-Version   and  CRC  flag."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 13
    BYTES                        = 1
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PACKET_TYPE"
    DESCRIPTION                  = "Telemetry   packet   type."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 14
    BYTES                        = 1
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PACKET_SUBTYPE"
    DESCRIPTION                  = "Telemetry   packet   sub-type."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 15
    BYTES                        = 1
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PACKET_PAD_FIELD"
    DESCRIPTION                  = "Telemetry   packet   padding  field."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 16
    BYTES                        = 1
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "STRUCTURE_ID"
    DESCRIPTION                  = "Telemetry   packet   structure   identifier."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 17
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "SOFTWARE_VERSION"
    DESCRIPTION                  = "On-board   software    version."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 19
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
                                                         Document No.       : MID-IWF-TN-0087
           ROSETTA-MIDAS to PSA                          Issue/Rev. No.     : 2.0
           Interface Control Document                    Date               : 16 November 2017
                                                         Page               : 97

    NAME                         = "LINEAR_POS"
    DESCRIPTION                  = "Linear   stage  position   sensor  readout."
    DATA_TYPE                    = MSB_INTEGER
    START_BYTE                   = 21
    BYTES                        = 2
    OFFSET                       = 1.52590E-004
    SCALING_FACTOR               = 3.05180E-004
    UNIT                         = VOLT
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "WHEEL_POS"
    DESCRIPTION                  = "Current   wheel  position   (segment   number)."
    DATA_TYPE                    = MSB_INTEGER
    START_BYTE                   = 23
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "TIP_NUMBER"
    DESCRIPTION                  = "Number   of selected   tip."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 25
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "X_ORIGIN"
    DESCRIPTION                  = "Scan  origin   in X  direction   (DAC  units)."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 27
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "Y_ORIGIN"
    DESCRIPTION                  = "Scan  origin   in Y  direction   (DAC  units)."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 29
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "STEP_SIZE"
    DESCRIPTION                  = "Line  scan  step  size  (DAC  units)."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 31
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "NUM_STEPS"
    DESCRIPTION                  = "Number   of line  scan  steps   (pixels)."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 33
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "SCAN_MODE"
    DESCRIPTION                  = "Scanning   mode  for  image  acquisition):
                                     Bit 0-7:   0=DYN[amic],   1=CON[tact],   2=MAG[netic],
                                     Bit    8:  line  scan direction   (0=std.,1=reverse),
                                     Bit  12:   main  scan direction   (0=X,1=Y)"
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 35
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "LINE_SCAN_CNT"
    DESCRIPTION                  = "Current   line  scan  counter."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 37
    BYTES                        = 2
                                                        Document No.        : MID-IWF-TN-0087
           ROSETTA-MIDAS to PSA                         Issue/Rev. No.      : 2.0
           Interface Control Document                   Date                : 16 November 2017
                                                        Page                : 98

END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "SPARE"
    DESCRIPTION                  = "Currently   not  used."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 39
    BYTES                        = 8
    ITEMS                        = 4
    ITEM_BYTES                   = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "Z_SET_VALUE"
    DESCRIPTION                  = "Line  scan  data  vector   (Z piezo   DAC set  value)."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 47
    BYTES                        = 1024
    ITEMS                        = 512
    ITEM_BYTES                   = 2
    SCALING_FACTOR               = 1.6400E-001
    OFFSET                       = 0.0000E+000
    UNIT                         = "nm"
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "CRC16_CHECKSUM"
    DESCRIPTION                  = "Telemetry   packet   checksum   (CRC  16)."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 1071
    BYTES                        = 2
END_OBJECT                       = COLUMN
                                                                  Document No.         : MID-IWF-TN-0087
                      ROSETTA-MIDAS to PSA                        Issue/Rev. No.       : 2.0
                      Interface Control Document                  Date                 : 16 November 2017
                                                                  Page                 : 99

4.3.7  Data Product Design - Image Scan Data

      The MIDAS image data files are stored in BCR format which is described in chapter 3.2.4. Each
      data file has associated a detached PDS label with the same name as the data file it describes,
      but with the extension .LBL:
              Data directory:    /DATA/IMG
              File naming:       IMG_yydddhh_yydddhh_nnn_dd.IMG

      A typical PDS label for an image data file is given below:

       PDS_VERSION_ID                        = PDS3
       LABEL_REVISION_NOTE                   = "<LABEL_REVISION_NOTE>"

       RECORD_TYPE                           = FIXED_LENGTH
       RECORD_BYTES                          = 2048
       FILE_RECORDS                          = <FILE_RECORDS>

       DATA_SET_ID                           = "<DATA_SET_ID>"
       DATA_SET_NAME                         = "<DATA_SET_NAME>"

       PRODUCT_ID                            = "<PRODUCT_ID>"
       PRODUCT_VERSION_ID                    = "<PRODUCT_VERSION_ID>"
       PRODUCT_CREATION_TIME                 = <PRODUCT_CREATION_TIME>
       PRODUCT_TYPE                          = <PRODUCT_TYPE>
       PROCESSING_LEVEL_ID                   = <PROCESSING_LEVEL_ID>

       MISSION_ID                            = ROSETTA
       MISSION_NAME                          = "INTERNATIONAL    ROSETTA   MISSION"
       MISSION_PHASE_NAME                    = "<MISSION_PHASE_NAME>"

       INSTRUMENT_HOST_ID                    = <INSTRUMENT_HOST_ID>
       INSTRUMENT_HOST_NAME                  = "<INSTRUMENT_HOST_NAME>"
       INSTRUMENT_ID                         = <INSTRUMENT_ID>
       INSTRUMENT_NAME                       = "<INSTRUMENT_NAME>"
       INSTRUMENT_TYPE                       = "<INSTRUMENT_TYPE>"
       INSTRUMENT_MODE_ID                    = <INSTRUMENT_MODE_ID>
       INSTRUMENT_MODE_DESC                  = "<INSTRUMENT_MODE_DESC>"

       TARGET_NAME                           = "<TARGET_NAME>"
       TARGET_TYPE                           = "<TARGET_TYPE>"

       START_TIME                            = <START_TIME>
       STOP_TIME                             = <STOP_TIME>
       SPACECRAFT_CLOCK_START_COUNT          = "<START_COUNT>"
       SPACECRAFT_CLOCK_STOP_COUNT           = "<STOP_COUNT>"
       NATIVE_START_TIME                     = <NATIVE_START_TIME>
       NATIVE_STOP_TIME                      = <NATIVE_STOP_TIME>

       PRODUCER_ID                           = "<PRODUCER_ID>"
       PRODUCER_FULL_NAME                    = "<PRODUCER_FULL_NAME>"
       PRODUCER_INSTITUTION_NAME             = "<PRODUCER_INSTITUTION_NAME>"

       DATA_QUALITY_ID                       = <DATA_QUALITY_ID>
       DATA_QUALITY_DESC                     = "<DATA_QUALITY_DESC>"

       /* GEOMETRY   INFORMATION   */

       SC_SUN_POSITION_VECTOR                = <SC_SUN_POSITION_VECTOR>
       SC_TARGET_POSITION_VECTOR             = <SC_TARGET_POSITION_VECTOR>
       SC_TARGET_VELOCITY_VECTOR             = <SC_TARGET_VELOCITY_VECTOR>
       SPACECRAFT_ALTITUDE                   = <SPACECRAFT_ALTITUDE>
       SUB_SPACECRAFT_LATITUDE               = <SUB_SPACECRAFT_LATITUDE>
       SUB_SPACECRAFT_LONGITUDE              = <SUB_SPACECRAFT_LONGITUDE>
                                                             Document No.      : MID-IWF-TN-0087
               ROSETTA-MIDAS to PSA                          Issue/Rev. No.    : 2.0
               Interface Control Document                    Date              : 16 November 2017
                                                             Page              : 100

/* PIXEL  SCALING   (HORIZONTAL=X,    VERTICAL=Y)   */

HORIZONTAL_PIXEL_SCALE                = <HORIZONTAL_PIXEL_SCALE>
VERTICAL_PIXEL_SCALE                  = <VERTICAL_PIXEL_SCALE>

/* MISSION   SPECIFIC  KEYWORDS   */

ROSETTA:MIDAS_TIP_NUMBER              = <MIDAS_TIP_NUMBER>
ROSETTA:MIDAS_TARGET_NUMBER           = <MIDAS_TARGET_NUMBER>
ROSETTA:MIDAS_TARGET_TYPE             = <MIDAS_TARGET_TYPE>
ROSETTA:MIDAS_TARGET_NAME             = <MIDAS_TARGET_NAME>

ROSETTA:MIDAS_LIN_STAGE_POS           = <MIDAS_LIN_STAGE_POS>
ROSETTA:MIDAS_SEGMENT_NUMBER          = <MIDAS_SEGMENT_NUMBER>
ROSETTA:MIDAS_SCAN_START_XY           = <MIDAS_SCAN_START_XY>
ROSETTA:MIDAS_SCAN_STOP_XY            = <MIDAS_SCAN_STOP_XY>
ROSETTA:MIDAS_SCAN_DIRECTION          = <MIDAS_SCAN_DIRECTION>

ROSETTA:MIDAS_SCANNING_MODE           = <MIDAS_SCANNING_MODE>
ROSETTA:MIDAS_SCAN_DATA_TYPE          = <MIDAS_SCAN_DATA_TYPE>

/* DATA  FILE  POINTER(S)   */

^BCR_HEADER                           = "<FILE_NAME>"
^BCR_IMAGE                            = ("<FILE_NAME>",2)

OBJECT                                = BCR_HEADER
    BYTES                             = 2048
    HEADER_TYPE                       = TEXT
    INTERCHANGE_FORMAT                = BINARY
    RECORDS                           = 1
    DESCRIPTION                       = "
    BCR-STM   format  as  used  by the  Image  Metrology   SPIP  application.
    Parameter   definitions    are given   in file  /DOCUMENT/MID_EIDC.pdf"
END_OBJECT                            = BCR_HEADER

OBJECT                                = BCR_IMAGE
    LINES                             = <LINES>
    LINE_SAMPLES                      = <LINE_SAMPLES>
    SAMPLE_BITS                       = 16
    SAMPLE_TYPE                       = LSB_UNSIGNED_INTEGER
    DESCRIPTION                       = "<DESCRIPTION>"
    SCALING_FACTOR                    = <SCALING_FACTOR>
    OFFSET                            = <OFFSET>
END_OBJECT                            = BCR_IMAGE

END
                                                                   Document No.        : MID-IWF-TN-0087
                      ROSETTA-MIDAS to PSA                         Issue/Rev. No.      : 2.0
                      Interface Control Document                   Date                : 16 November 2017
                                                                   Page                : 101

4.3.8  Data Product Design - Feature Vector Data

      The MIDAS feature vector data files are binary tables containing the plain telemetry packets as
      retrieved from  the  DDS.  Each   data   file has associated  a detached  PDS      label with the same
      name as the data file it describes, but with the extension .LBL. The data file columns are defined
      in a separate format file referred to by the ^STRUCTURE keyword in the PDS labels:
              Data directory:    /DATA/ROI
              File naming:       ROI_yydddhh_yydddhh_nnn_ff.DAT
              File structure:    /LABEL/ROI_STRUCTURE.FMT
      Parameters    having  a  physical representation     can be   calibrated by    applying  the  OFFSET,
      SCALING_FACTOR and UNIT keywords (defined in the related column object in the format file)
      to the raw value:
              physical_value = OFFSET + raw_value*SCALING_FACTOR [UNIT]
      A feature vector record comprises 64 feature vector frames having identical vector parameters.
      The actual number of feature vectors for a record is given in the NUM_VECTORS column. The
      repeating  structure of the 64  feature    vectors is defined by   means  of   the  PDS   CONTAINER
      object.

      A typical PDS label for a feature vector data file is given below:

       PDS_VERSION_ID                        = PDS3
       LABEL_REVISION_NOTE                   = "<LABEL_REVISION_NOTE>"

       RECORD_TYPE                           = FIXED_LENGTH
       RECORD_BYTES                          = 2096
       FILE_RECORDS                          = <FILE_RECORDS>

       DATA_SET_ID                           = "<DATA_SET_ID>"
       DATA_SET_NAME                         = "<DATA_SET_NAME>"

       PRODUCT_ID                            = "<PRODUCT_ID>"
       PRODUCT_VERSION_ID                    = "<PRODUCT_VERSION_ID>"
       PRODUCT_CREATION_TIME                 = <PRODUCT_CREATION_TIME>
       PRODUCT_TYPE                          = <PRODUCT_TYPE>
       PROCESSING_LEVEL_ID                   = <PROCESSING_LEVEL_ID>

       MISSION_ID                            = ROSETTA
       MISSION_NAME                          = "INTERNATIONAL    ROSETTA   MISSION"
       MISSION_PHASE_NAME                    = "<MISSION_PHASE_NAME>"

       INSTRUMENT_HOST_ID                    = <INSTRUMENT_HOST_ID>
       INSTRUMENT_HOST_NAME                  = "<INSTRUMENT_HOST_NAME>"
       INSTRUMENT_ID                         = <INSTRUMENT_ID>
       INSTRUMENT_NAME                       = "<INSTRUMENT_NAME>"
       INSTRUMENT_TYPE                       = "<INSTRUMENT_TYPE>"
       INSTRUMENT_MODE_ID                    = <INSTRUMENT_MODE_ID>
       INSTRUMENT_MODE_DESC                  = "<INSTRUMENT_MODE_DESC>"

       TARGET_NAME                           = "<TARGET_NAME>"
       TARGET_TYPE                           = "<TARGET_TYPE>"

       START_TIME                            = <START_TIME>
       STOP_TIME                             = <STOP_TIME>
       SPACECRAFT_CLOCK_START_COUNT          = "<START_COUNT>"
       SPACECRAFT_CLOCK_STOP_COUNT           = "<STOP_COUNT>"
       NATIVE_START_TIME                     = <NATIVE_START_TIME>
       NATIVE_STOP_TIME                      = <NATIVE_STOP_TIME>
                                                              Document No.      :  MID-IWF-TN-0087
                ROSETTA-MIDAS to PSA                          Issue/Rev. No.    :  2.0
                Interface Control Document                    Date              :  16 November 2017
                                                              Page              :  102

PRODUCER_ID                           = "<PRODUCER_ID>"
PRODUCER_FULL_NAME                    = "<PRODUCER_FULL_NAME>"
PRODUCER_INSTITUTION_NAME             = "<PRODUCER_INSTITUTION_NAME>"

DATA_QUALITY_ID                       = <DATA_QUALITY_ID>
DATA_QUALITY_DESC                     = "<DATA_QUALITY_DESC>"

/* GEOMETRY   INFORMATION   */

SC_SUN_POSITION_VECTOR                = <SC_SUN_POSITION_VECTOR>
SC_TARGET_POSITION_VECTOR             = <SC_TARGET_POSITION_VECTOR>
SC_TARGET_VELOCITY_VECTOR             = <SC_TARGET_VELOCITY_VECTOR>
SPACECRAFT_ALTITUDE                   = <SPACECRAFT_ALTITUDE>
SUB_SPACECRAFT_LATITUDE               = <SUB_SPACECRAFT_LATITUDE>
SUB_SPACECRAFT_LONGITUDE              = <SUB_SPACECRAFT_LONGITUDE>

/* DATA  FILE  POINTER(S)   */

^ROI_TABLE                            = "<FILE_NAME>"

/* DATA  OBJECT   DEFINITION(S)   */

OBJECT                                = ROI_TABLE
    INTERCHANGE_FORMAT                = BINARY
    ROWS                              = <FILE_RECORDS>
    COLUMNS                           = 35
    ROW_BYTES                         = 2096
    DESCRIPTION                       = "MIDAS   feature  vector   data"
    ^STRUCTURE                        = "ROI_STRUCTURE.FMT"
END_OBJECT                            = ROI_TABLE

END

The feature vector structure is defined as follows:

    /*  MIDAS  FEATURE   VECTOR  FRAME  STRUCTURE   */

    OBJECT                            = COLUMN
         NAME                         = "PACKET_ID"
         DESCRIPTION                  = "Telemetry   packet   identifier."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 1
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "PACKET_SEQUENCE_CONTROL"
         DESCRIPTION                  = "Telemetry   packet   sequence   counter."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 3
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "PACKET_LENGTH"
         DESCRIPTION                  = "Telemetry   packet   length."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 5
         BYTES                        = 2
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "PACKET_OBT_SECONDS"
         DESCRIPTION                  = "S/C  clock  count   at packet   generation."
         DATA_TYPE                    = MSB_UNSIGNED_INTEGER
         START_BYTE                   = 7
         BYTES                        = 4
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = "PACKET_OBT_FRACTION"
         DESCRIPTION                  = "Fractional    part  of S/C  clock  count."
                                                         Document No.       : MID-IWF-TN-0087
           ROSETTA-MIDAS to PSA                          Issue/Rev. No.     : 2.0
           Interface Control Document                    Date               : 16 November 2017
                                                         Page               : 103

    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 11
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PACKET_PUS_AND_CRC"
    DESCRIPTION                  = "Telemetry   packet   PUS-Version   and  CRC  flag."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 13
    BYTES                        = 1
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PACKET_TYPE"
    DESCRIPTION                  = "Telemetry   packet   type."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 14
    BYTES                        = 1
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PACKET_SUBTYPE"
    DESCRIPTION                  = "Telemetry   packet   sub-type."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 15
    BYTES                        = 1
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "PACKET_PAD_FIELD"
    DESCRIPTION                  = "Telemetry   packet   padding  field."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 16
    BYTES                        = 1
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "STRUCTURE_ID"
    DESCRIPTION                  = "Telemetry   packet   structure   identifier."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 17
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "SOFTWARE_VERSION"
    DESCRIPTION                  = "On-board   software   version."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 19
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "DATASET_ID"
    DESCRIPTION                  = "Identifier    of analysed   data  set."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 21
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "TOT_VECTORS"
    DESCRIPTION                  = "Total   number  of  detected  features."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 23
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "VECTOR_IDX"
    DESCRIPTION                  = "Index   of first  feature   vector  (x2)."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 25
    BYTES                        = 2
                                                         Document No.       : MID-IWF-TN-0087
           ROSETTA-MIDAS to PSA                          Issue/Rev. No.     : 2.0
           Interface Control Document                    Date               : 16 November 2017
                                                         Page               : 104

END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "NUM_VECTORS"
    DESCRIPTION                  = "Number   of feature   vectors   in packet."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 27
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "MIN_Z_VALUE"
    DESCRIPTION                  = "Minimum   Z value   of image."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 29
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "MAX_Z_VALUE"
    DESCRIPTION                  = "Maximum   Z value   of image."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 31
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "SELECTED_IDX"
    DESCRIPTION                  = "Index   of  favoured   feature  vector."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 33
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "SELECTED_WEIGHT"
    DESCRIPTION                  = "Weighting   of  favoured   feature  vector."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 35
    BYTES                        = 2
    SCALING_FACTOR               = 6.1036E-5
    OFFSET                       = 0.0
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "LIN_REG_OFFS"
    DESCRIPTION                  = "Linear   regression   offset  value."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 37
    BYTES                        = 2
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "LIN_REG_XFACT"
    DESCRIPTION                  = "Linear   regression   X factor   (x65535)."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 39
    BYTES                        = 4
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = "LIN_REG_YFACT"
    DESCRIPTION                  = "Linear   regression   Y factor   (x65535)."
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 43
    BYTES                        = 4
END_OBJECT                       = COLUMN

OBJECT                           = CONTAINER
    NAME                         = "VECTOR_STRUCTURE"
    START_BYTE                   = 47
    BYTES                        = 32
    REPETITIONS                  = 64
    DESCRIPTION                  = "Represents    the format   of the  64
                                     repeating  feature    vector attributes."
                                                     Document No.      : MID-IWF-TN-0087
       ROSETTA-MIDAS to PSA                          Issue/Rev. No.    : 2.0
       Interface Control Document                    Date              : 16 November 2017
                                                     Page              : 105

OBJECT                      =  COLUMN
    NAME                    =  "NUM_POINTS"
    DATA_TYPE               =  MSB_UNSIGNED_INTEGER
    START_BYTE              =  1
    BYTES                   =  2
    DESCRIPTION             =  "Number  of  feature   vector  data  points."
END_OBJECT                  =  COLUMN

OBJECT                      =  COLUMN
    NAME                    =  "X_IDX_MAX"
    DATA_TYPE               =  MSB_UNSIGNED_INTEGER
    START_BYTE              =  3
    BYTES                   =  1
    DESCRIPTION             =  "Maximum   X position   index."
END_OBJECT                  =  COLUMN

OBJECT                      =  COLUMN
    NAME                    =  X_IDX_MIN
    DATA_TYPE               =  MSB_UNSIGNED_INTEGER
    START_BYTE              =  4
    BYTES                   =  1
    DESCRIPTION             =  "Minimum   X position   index."
END_OBJECT                  =  COLUMN

OBJECT                      =  COLUMN
    NAME                    =  Y_IDX_MAX
    DATA_TYPE               =  MSB_UNSIGNED_INTEGER
    START_BYTE              =  5
    BYTES                   =  1
    DESCRIPTION             =  "Maximum   y position   index."
END_OBJECT                  =  COLUMN

OBJECT                      =  COLUMN
    NAME                    =  Y_IDX_MIN
    DATA_TYPE               =  MSB_UNSIGNED_INTEGER
    START_BYTE              =  6
    BYTES                   =  1
    DESCRIPTION             =  "Minimum   Y position   index."
END_OBJECT                  =  COLUMN

OBJECT                      =  COLUMN
    NAME                    =  Z_MAX_LVL
    DATA_TYPE               =  MSB_UNSIGNED_INTEGER
    START_BYTE              =  7
    BYTES                   =  2
    DESCRIPTION             =  "Maximum   Z value  over  threshold   level."
END_OBJECT                  =  COLUMN

OBJECT                      =  COLUMN
    NAME                    =  X_IDX_SUM
    DATA_TYPE               =  MSB_UNSIGNED_INTEGER
    START_BYTE              =  9
    BYTES                   =  4
    DESCRIPTION             =  "Sum  of X  position   indices."
END_OBJECT                  =  COLUMN

OBJECT                      =  COLUMN
    NAME                    =  Y_IDX_SUM
    DATA_TYPE               =  MSB_UNSIGNED_INTEGER
    START_BYTE              =  13
    BYTES                   =  4
    DESCRIPTION             =  "Sum  of Y   position  indices."
END_OBJECT                  =  COLUMN

OBJECT                      =  COLUMN
    NAME                    =  Z_IDX_SUM
    DATA_TYPE               =  MSB_UNSIGNED_INTEGER
    START_BYTE              =  17
    BYTES                   =  4
    DESCRIPTION             =  "Sum  of Z  position   indices."
END_OBJECT                  =  COLUMN

OBJECT                      =  COLUMN
                                                        Document No.        : MID-IWF-TN-0087
           ROSETTA-MIDAS to PSA                         Issue/Rev. No.      : 2.0
           Interface Control Document                   Date                : 16 November 2017
                                                        Page                : 106

         NAME                    = XX_IDX_SUM
         DATA_TYPE               = MSB_UNSIGNED_INTEGER
         START_BYTE              = 21
         BYTES                   = 4
         DESCRIPTION             = "Sum  of  X*X  position  indices."
    END_OBJECT                   = COLUMN

    OBJECT                       = COLUMN
         NAME                    = YY_IDX_SUM
         DATA_TYPE               = MSB_UNSIGNED_INTEGER
         START_BYTE              = 25
         BYTES                   = 4
         DESCRIPTION             = "Sum  of  Y*Y  position  indices."
    END_OBJECT                   = COLUMN

    OBJECT                       = COLUMN
         NAME                    = XY_IDX_SUM
         DATA_TYPE               = MSB_UNSIGNED_INTEGER
         START_BYTE              = 29
         BYTES                   = 4
         DESCRIPTION             = "Sum  of  X*Y  position  indices."
    END_OBJECT                   = COLUMN
END_OBJECT                       = CONTAINER

OBJECT                           = COLUMN
    NAME                         = CRC16_CHECKSUM
    DATA_TYPE                    = MSB_UNSIGNED_INTEGER
    START_BYTE                   = 2095
    BYTES                        = 2
    DESCRIPTION                  = "Telemetry   packet   checksum   (CRC  16)."
END_OBJECT                       = COLUMN
                                                                  Document No.         : MID-IWF-TN-0087
                      ROSETTA-MIDAS to PSA                        Issue/Rev. No.       : 2.0
                      Interface Control Document                  Date                 : 16 November 2017
                                                                  Page                 : 107

4.3.9  Data Product Design - Event Data

      The MIDAS event data files are ASCII tables containing the list of events within a given time
      period. Each data file has associated a detached PDS label with the same name as the data file
      it describes, but with the extension .LBL. The data file columns are defined in a separate format
      file referred to by the ^STRUCTURE keyword in the PDS labels:
              Data directory:    /DATA/EVN
              File naming:       EVN_yydddhh_yydddhh.TAB
              File structure:    /LABEL/EVN_STRUCTURE.FMT

      A typical PDS label for an event data file is given below:

       PDS_VERSION_ID                        = PDS3
       LABEL_REVISION_NOTE                   = "<LABEL_REVISION_NOTE>"

       RECORD_TYPE                           = FIXED_LENGTH
       RECORD_BYTES                          = 80
       FILE_RECORDS                          = <FILE_RECORDS>

       DATA_SET_ID                           = "<DATA_SET_ID>"
       DATA_SET_NAME                         = "<DATA_SET_NAME>"

       PRODUCT_ID                            = "<PRODUCT_ID>"
       PRODUCT_VERSION_ID                    = "<PRODUCT_VERSION_ID>"
       PRODUCT_CREATION_TIME                 = <PRODUCT_CREATION_TIME>
       PRODUCT_TYPE                          = <PRODUCT_TYPE>
       PROCESSING_LEVEL_ID                   = <PROCESSING_LEVEL_ID>

       MISSION_ID                            = ROSETTA
       MISSION_NAME                          = "INTERNATIONAL    ROSETTA   MISSION"
       MISSION_PHASE_NAME                    = "<MISSION_PHASE_NAME>"

       INSTRUMENT_HOST_ID                    = <INSTRUMENT_HOST_ID>
       INSTRUMENT_HOST_NAME                  = "<INSTRUMENT_HOST_NAME>"
       INSTRUMENT_ID                         = <INSTRUMENT_ID>
       INSTRUMENT_NAME                       = "<INSTRUMENT_NAME>"
       INSTRUMENT_TYPE                       = "<INSTRUMENT_TYPE>"
       INSTRUMENT_MODE_ID                    = <INSTRUMENT_MODE_ID>
       INSTRUMENT_MODE_DESC                  = "<INSTRUMENT_MODE_DESC>"

       TARGET_NAME                           = "<TARGET_NAME>"
       TARGET_TYPE                           = "<TARGET_TYPE>"

       START_TIME                            = <START_TIME>
       STOP_TIME                             = <STOP_TIME>
       SPACECRAFT_CLOCK_START_COUNT          = "<START_COUNT>"
       SPACECRAFT_CLOCK_STOP_COUNT           = "<STOP_COUNT>"
       NATIVE_START_TIME                     = <NATIVE_START_TIME>
       NATIVE_STOP_TIME                      = <NATIVE_STOP_TIME>

       PRODUCER_ID                           = "<PRODUCER_ID>"
       PRODUCER_FULL_NAME                    = "<PRODUCER_FULL_NAME>"
       PRODUCER_INSTITUTION_NAME             = "<PRODUCER_INSTITUTION_NAME>"

       DATA_QUALITY_ID                       = <DATA_QUALITY_ID>
       DATA_QUALITY_DESC                     = "<DATA_QUALITY_DESC>"

       /* GEOMETRY   INFORMATION   */

       SC_SUN_POSITION_VECTOR                = <SC_SUN_POSITION_VECTOR>
       SC_TARGET_POSITION_VECTOR             = <SC_TARGET_POSITION_VECTOR>
       SC_TARGET_VELOCITY_VECTOR             = <SC_TARGET_VELOCITY_VECTOR>
       SPACECRAFT_ALTITUDE                   = <SPACECRAFT_ALTITUDE>
                                                              Document No.      : MID-IWF-TN-0087
                ROSETTA-MIDAS to PSA                          Issue/Rev. No.    : 2.0
                Interface Control Document                    Date              : 16 November 2017
                                                              Page              : 108

SUB_SPACECRAFT_LATITUDE               = <SUB_SPACECRAFT_LATITUDE>
SUB_SPACECRAFT_LONGITUDE              = <SUB_SPACECRAFT_LONGITUDE>

/* DATA  FILE  POINTER(S)   */

^EVENT_TABLE                            =  "<FILE_NAME>"

/* DATA  OBJECT   DEFINITION(S)   */

OBJECT                                = EVENT_TABLE
    INTERCHANGE_FORMAT                = ASCII
    ROWS                              = <FILE_RECORDS>
    COLUMNS                           = 5
    ROW_BYTES                         = 80
    DESCRIPTION                       = "MIDAS   event  data"
    ^STRUCTURE                        = "EVN_STRUCTURE.FMT"
END_OBJECT                            = EVENT_TABLE

END

The event data file structure is defined as follows:

    /*  EVENT  DATA  STRUCTURE   */

    OBJECT                            = COLUMN
         NAME                         = EVENT_OBT
         DATA_TYPE                    = ASCII_REAL
         START_BYTE                   = 1
         BYTES                        = 14
         UNIT                         = SECOND
         DESCRIPTION                  = "S/C  clock  count   at event  generation."
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = EVENT_UTC
         DATA_TYPE                    = DATE
         START_BYTE                   = 16
         BYTES                        = 23
         DESCRIPTION                  = "Event   generation   time  in UTC  format."
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = EVENT_CNT
         DATA_TYPE                    = ASCII_INTEGER
         START_BYTE                   = 40
         BYTES                        = 5
         DESCRIPTION                  = "On-board   event  counter."
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = EVENT_SID
         DATA_TYPE                    = ASCII_INTEGER
         START_BYTE                   = 46
         BYTES                        = 5
         DESCRIPTION                  = "Event   identifier."
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = EVENT_NAME
         DATA_TYPE                    = CHARACTER
         START_BYTE                   = 53
         BYTES                        = 25
         DESCRIPTION                  = "Event   description."
    END_OBJECT                        = COLUMN
                                                                  Document No.         : MID-IWF-TN-0087
                       ROSETTA-MIDAS to PSA                       Issue/Rev. No.       : 2.0
                       Interface Control Document                 Date                 : 16 November 2017
                                                                  Page                 : 109

4.3.10 Data Product Design - Cantilever Utilisation History Data

     The MIDAS cantilever history data files are ASCII tables containing the list of events for a certain
     cantilever within a given time period. Each data file has associated a detached PDS label with
     the same name as the data file it describes, but with the extension .LBL. The data file columns
     are defined in a separate format file referred to by the ^STRUCTURE keyword in the PDS labels:
               Data directory:    /DATA
               File naming:       CAH_yydddhh_yydddhh_tt.TAB
               File structure:    /LABEL/CAH_STRUCTURE.FMT

     A typical PDS label for a cantilever history data file is given below:

       PDS_VERSION_ID                        = PDS3
       LABEL_REVISION_NOTE                   = "<LABEL_REVISION_NOTE>"

       RECORD_TYPE                           = FIXED_LENGTH
       RECORD_BYTES                          = 119
       FILE_RECORDS                          = <FILE_RECORDS>

       DATA_SET_ID                           = "<DATA_SET_ID>"
       DATA_SET_NAME                         = "<DATA_SET_NAME>"

       PRODUCT_ID                            = "<PRODUCT_ID>"
       PRODUCT_VERSION_ID                    = "<PRODUCT_VERSION_ID>"
       PRODUCT_CREATION_TIME                 = <PRODUCT_CREATION_TIME>
       PRODUCT_TYPE                          = <PRODUCT_TYPE>
       PROCESSING_LEVEL_ID                   = <PROCESSING_LEVEL_ID>

       MISSION_ID                            = ROSETTA
       MISSION_NAME                          = "INTERNATIONAL    ROSETTA   MISSION"
       MISSION_PHASE_NAME                    = "<MISSION_PHASE_NAME>"

       INSTRUMENT_HOST_ID                    = <INSTRUMENT_HOST_ID>
       INSTRUMENT_HOST_NAME                  = "<INSTRUMENT_HOST_NAME>"
       INSTRUMENT_ID                         = <INSTRUMENT_ID>
       INSTRUMENT_NAME                       = "<INSTRUMENT_NAME>"
       INSTRUMENT_TYPE                       = "<INSTRUMENT_TYPE>"
       INSTRUMENT_MODE_ID                    = <INSTRUMENT_MODE_ID>
       INSTRUMENT_MODE_DESC                  = "<INSTRUMENT_MODE_DESC>"

       TARGET_NAME                           = "<TARGET_NAME>"
       TARGET_TYPE                           = "<TARGET_TYPE>"

       START_TIME                            = <START_TIME>
       STOP_TIME                             = <STOP_TIME>
       SPACECRAFT_CLOCK_START_COUNT          = "<START_COUNT>"
       SPACECRAFT_CLOCK_STOP_COUNT           = "<STOP_COUNT>"
       NATIVE_START_TIME                     = <NATIVE_START_TIME>
       NATIVE_STOP_TIME                      = <NATIVE_STOP_TIME>

       PRODUCER_ID                           = "<PRODUCER_ID>"
       PRODUCER_FULL_NAME                    = "<PRODUCER_FULL_NAME>"
       PRODUCER_INSTITUTION_NAME             = "<PRODUCER_INSTITUTION_NAME>"

       DATA_QUALITY_ID                       = <DATA_QUALITY_ID>
       DATA_QUALITY_DESC                     = "<DATA_QUALITY_DESC>"

       /* DATA  FILE  POINTER(S)   */

       ^EVENT_TABLE                          = "<FILE_NAME>"

       /* DATA  OBJECT   DEFINITION(S)   */
                                                              Document No.       : MID-IWF-TN-0087
               ROSETTA-MIDAS to PSA                           Issue/Rev. No.     : 2.0
               Interface Control Document                     Date               : 16 November 2017
                                                              Page               : 110

OBJECT                                = EVENT_TABLE
    NAME                              = CANTILEVER_HISTORY
    INTERCHANGE_FORMAT                = ASCII
    ROWS                              = <FILE_RECORDS>
    COLUMNS                           = 11
    ROW_BYTES                         = 119
    DESCRIPTION                       = "MIDAS   cantilever   history   data"
    ^STRUCTURE                        = "CAH_STRUCTURE.FMT"
END_OBJECT                            = EVENT_TABLE

END

The cantilever history data structure is defined as follows:

    /*  CANTILEVER   HISTORY   DATA  STRUCTURE   */

    OBJECT                            = COLUMN
         NAME                         = START_OBT
         DATA_TYPE                    = ASCII_REAL
         START_BYTE                   = 1
         BYTES                        = 15
         UNIT                         = SECOND
         DESCRIPTION                  = "S/C  clock  count   at event   start."
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = START_UTC
         DATA_TYPE                    = DATE
         START_BYTE                   = 17
         BYTES                        = 23
         DESCRIPTION                  = "Event   start  time  in UTC  format."
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = STOP_OBT
         DATA_TYPE                    = ASCII_REAL
         START_BYTE                   = 41
         BYTES                        = 15
         UNIT                         = SECOND
         DESCRIPTION                  = "S/C  clock  count   at event   stop."
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = STOP_UTC
         DATA_TYPE                    = DATE
         START_BYTE                   = 57
         BYTES                        = 23
         DESCRIPTION                  = "Event   stop  time  in  UTC format."
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = EVENT
         DATA_TYPE                    = CHARACTER
         START_BYTE                   = 82
         BYTES                        = 8
         DESCRIPTION                  = "Textual   description   of  the  event."
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = AC_GAIN
         DATA_TYPE                    = ASCII_INTEGER
         START_BYTE                   = 93
         BYTES                        = 1
         DESCRIPTION                  = "Gain  level   of cantilever    AC signal
                                          amplifier   [0-7]."
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = DC_GAIN
         DATA_TYPE                    = ASCII_INTEGER
         START_BYTE                   = 95
                                                         Document No.       : MID-IWF-TN-0087
           ROSETTA-MIDAS to PSA                          Issue/Rev. No.     : 2.0
           Interface Control Document                    Date               : 16 November 2017
                                                         Page               : 111

    BYTES                        = 1
    DESCRIPTION                  = "Gain  level   of cantilever   DC  signal
                                     amplifier  [0-7]."
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = EXC_LVL
    DATA_TYPE                    = ASCII_INTEGER
    START_BYTE                   = 97
    BYTES                        = 1
    DESCRIPTION                  = "Gain  level   of piezo-electric    actuator
                                     used for  cantilever   excitation    [0-7]."
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = U_MAX
    DATA_TYPE                    = ASCII_REAL
    UNIT                         = VOLT
    START_BYTE                   = 99
    BYTES                        = 5
    DESCRIPTION                  = "Max.  cantilever    signal  amplitude
                                     detected  during   frequency   scan."
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = F_MAX
    DATA_TYPE                    = ASCII_REAL
    UNIT                         = HERTZ
    START_BYTE                   = 105
    BYTES                        = 8
    DESCRIPTION                  = "Frequency   where   the maximum
                                     signal  amplitude   was  detected."
END_OBJECT                       = COLUMN

OBJECT                           = COLUMN
    NAME                         = SCAN_MODE
    DATA_TYPE                    = CHARACTER
    START_BYTE                   = 115
    BYTES                        = 3
    DESCRIPTION                  = "Scanning   mode  for  image  acquisition    e.g.
                                     DYN[amic],   CON[tact]   or MAG[netic]."
END_OBJECT                       = COLUMN
                                                                  Document No.         : MID-IWF-TN-0087
                       ROSETTA-MIDAS to PSA                       Issue/Rev. No.       : 2.0
                       Interface Control Document                 Date                 : 16 November 2017
                                                                  Page                 : 112

4.3.11 Data Product Design - Target Utilisation History Data

     The MIDAS target history data files are ASCII tables containing the list of events for a certain
     target within a given time period. Each data file has associated a detached PDS label with the
     same name as the data file it describes, but with the extension .LBL. The data file columns are
     defined in a separate format file referred to by the ^STRUCTURE keyword in the PDS labels:
               Data directory:    /DATA
               File naming:       TGH_yydddhh_yydddhh_tt.TAB
               File structure:    /LABEL/TGH_STRUCTURE.FMT

     A typical PDS label for a target history data file is given below:

       PDS_VERSION_ID                        = PDS3
       LABEL_REVISION_NOTE                   = "<LABEL_REVISION_NOTE>"

       RECORD_TYPE                           = FIXED_LENGTH
       RECORD_BYTES                          = 95
       FILE_RECORDS                          = <FILE_RECORDS>

       DATA_SET_ID                           = "<DATA_SET_ID>"
       DATA_SET_NAME                         = "<DATA_SET_NAME>"

       PRODUCT_ID                            = "<PRODUCT_ID>"
       PRODUCT_VERSION_ID                    = "<PRODUCT_VERSION_ID>"
       PRODUCT_CREATION_TIME                 = <PRODUCT_CREATION_TIME>
       PRODUCT_TYPE                          = <PRODUCT_TYPE>
       PROCESSING_LEVEL_ID                   = <PROCESSING_LEVEL_ID>

       MISSION_ID                            = ROSETTA
       MISSION_NAME                          = "INTERNATIONAL    ROSETTA   MISSION"
       MISSION_PHASE_NAME                    = "<MISSION_PHASE_NAME>"

       INSTRUMENT_HOST_ID                    = <INSTRUMENT_HOST_ID>
       INSTRUMENT_HOST_NAME                  = "<INSTRUMENT_HOST_NAME>"
       INSTRUMENT_ID                         = <INSTRUMENT_ID>
       INSTRUMENT_NAME                       = "<INSTRUMENT_NAME>"
       INSTRUMENT_TYPE                       = "<INSTRUMENT_TYPE>"
       INSTRUMENT_MODE_ID                    = <INSTRUMENT_MODE_ID>
       INSTRUMENT_MODE_DESC                  = "<INSTRUMENT_MODE_DESC>"

       TARGET_NAME                           = "<TARGET_NAME>"
       TARGET_TYPE                           = "<TARGET_TYPE>"

       START_TIME                            = <START_TIME>
       STOP_TIME                             = <STOP_TIME>
       SPACECRAFT_CLOCK_START_COUNT          = "<START_COUNT>"
       SPACECRAFT_CLOCK_STOP_COUNT           = "<STOP_COUNT>"
       NATIVE_START_TIME                     = <NATIVE_START_TIME>
       NATIVE_STOP_TIME                      = <NATIVE_STOP_TIME>

       PRODUCER_ID                           = "<PRODUCER_ID>"
       PRODUCER_FULL_NAME                    = "<PRODUCER_FULL_NAME>"
       PRODUCER_INSTITUTION_NAME             = "<PRODUCER_INSTITUTION_NAME>"

       DATA_QUALITY_ID                       = <DATA_QUALITY_ID>
       DATA_QUALITY_DESC                     = "<DATA_QUALITY_DESC>"

       /* DATA  FILE  POINTER(S)   */

       ^EVENT_TABLE                          = "<FILE_NAME>"

       /* DATA  OBJECT   DEFINITION(S)   */
                                                              Document No.       : MID-IWF-TN-0087
               ROSETTA-MIDAS to PSA                           Issue/Rev. No.     : 2.0
               Interface Control Document                     Date               : 16 November 2017
                                                              Page               : 113

OBJECT                                = EVENT_TABLE
    NAME                              = TARGET_HISTORY
    INTERCHANGE_FORMAT                = ASCII
    ROWS                              = <FILE_RECORDS>
    COLUMNS                           = 6
    ROW_BYTES                         = 95
    DESCRIPTION                       = "MIDAS   target  history  data"
    ^STRUCTURE                        = "TGH_STRUCTURE.FMT"
END_OBJECT                            = EVENT_TABLE

END

The target history data structure is defined as follows:

    /*  TARGET  HISTORY   DATA  STRUCTURE   */

    OBJECT                            = COLUMN
         NAME                         = START_OBT
         DATA_TYPE                    = ASCII_REAL
         START_BYTE                   = 1
         BYTES                        = 15
         UNIT                         = SECOND
         DESCRIPTION                  = "S/C  clock  count  at  event   start."
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = START_UTC
         DATA_TYPE                    = DATE
         START_BYTE                   = 17
         BYTES                        = 23
         DESCRIPTION                  = "Event   start  time  in  UTC format."
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = STOP_OBT
         DATA_TYPE                    = ASCII_REAL
         START_BYTE                   = 41
         BYTES                        = 15
         UNIT                         = SECOND
         DESCRIPTION                  = "S/C  clock  count  at  event   stop."
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = STOP_UTC
         DATA_TYPE                    = DATE
         START_BYTE                   = 57
         BYTES                        = 23
         DESCRIPTION                  = "Event   stop  time in  UTC  format."
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = EVENT
         DATA_TYPE                    = CHARACTER
         START_BYTE                   = 82
         BYTES                        = 8
         DESCRIPTION                  = "Textual   description    of the  event."
    END_OBJECT                        = COLUMN

    OBJECT                            = COLUMN
         NAME                         = FLUX_OR_TIP
         DATA_TYPE                    = ASCII_INTEGER
         START_BYTE                   = 92
         BYTES                        = 2
         DESCRIPTION                  = "Maximum   dust  flux  or tip   number."
    END_OBJECT                        = COLUMN
                                                           Document No.           : MID-IWF-TN-0087
                    ROSETTA-MIDAS to PSA                   Issue/Rev. No.         : 2.0
                    Interface Control Document             Date                   : 16 November 2017
                                                           Page                   : 114

5  Appendix: Available Software to read PDS files

     The MIDAS archive data sets can be displayed and validated with the MIDAS Data Set Browser
     software. The contents of a MIDAS archive data set can be browsed by means of             a tree-like
     structure, displaying the data set directory hierarchy (nodes) an the associated data files (leafs).
     The software is entirely written in IDL and the source code is included in the data sets.

     Figure 5.1 shows a frequency scan from the RO-X-MIDAS-3-MARS-PC3-5 data set:

     The browser window is structured into two panels holding the following components (from top to
     bottom):
     Left Panel:      - Data set hierarchy window - used for navigation
                      - Data file attribute window - shows data file attributes (e.g. row prefix values)
                      - Plot parameter selection window - plot parameter selection
     Right Panel:     - Data file path windows - displays the full path of the selected PDS file
                      - Text window - displays text files or PDS data file labels
                      - Graphic/Table window - used for data plotting or tabular data display
                                                                    Document No.     :  MID-IWF-TN-0087
                      ROSETTA-MIDAS to PSA                          Issue/Rev. No.   :  2.0
                      Interface Control Document                    Date             :  16 November 2017
                                                                    Page             :  115

5.1   Program Description

5.1.1  Program Installation

      Before starting the program, the source files need to be copied to a directory on a machine
      having   IDL  (6.4  or higher) installed. The  source   files (extension  *.PRO)  are  located in the
      DOCUMENT       directory  of a data set.  In order   to make   IDL  aware  of the new   modules,  the
      directory   holding the   source  files   should be   added    to  the IDL  path  preferences   (File-
      >Preferences->Path).

5.1.2  Starting the Program

      After starting up IDL, the MIDAS Data Set Browser can be started with the following command:
      IDL> mid_browse [,_data_set_root]
      The parameter data_set_root is optional. It can be used to define the root directory of the MIDAS
      data set (usually the directory holding the AAREADME.TXT and VOLDESC.CAT files) at start-
      up. If this parameter is not present, the S/W displays a file selection dialog from where the root
      directory can be selected.

5.1.3  Navigating the Data Set

      The upper left window shows a tree-like structure displaying the data set hierarchy (directories
      and files).
      Directories can be expanded/collapsed by clicking on the `+'/'-` symbol in front of the directory
      icon. Double-clicking on the directory icon or the directory name toggles between expanded and
      collapsed mode.
      The up and down arrow keys can be used to navigate sequentially through the directories and
      files.
      Data set files are usually displayed with the file extension included. Nevertheless, in order to
      reduce the amount of displayed files, the file extension is stripped of from files located in the
      DATA    directory  and  all  subjacent  directories. This  results in  a common    filename  (without
      extension) for the data files and the respective PDS labels.

5.1.4  Data Display

      Information from a data set file can be retrieved by selecting the file in the data set hierarchy
      window (entry is highlighted).
      Text files:
      Data set files having the extension .CAT, .FMT, .LBL, .TAB and .TXT are displayed in the upper
      right text display window. No data validation is applied to these files.
      Adobe PDF files:
      When selecting a Portable Data Format file, the file is displayed in the application associated to
      the .PDF file extension on the system (if any).
                                                                   Document No.       : MID-IWF-TN-0087
                     ROSETTA-MIDAS to PSA                          Issue/Rev. No.     : 2.0
                     Interface Control Document                    Date               : 16 November 2017
                                                                   Page               : 116

      PNG Images:
      Images stored in PNG format are displayed in the graphic panel located in the lower right corner
      of the main window.
      Files in the DATA directory:
      Files located in and underneath the DATA directory are treated differently than the data set files
      already mentioned.
      PDS  labels are validated    and ^STRUCTURE       statements     are expanded.    The    resulting PDS
      labels are displayed in the text window. Comments are removed from the PDS labels.
      The  associated data   files are loaded   and  the information    is displayed    in several windows,
      depending on the data product type:
             EVN,   CAH    and TGH    Data:  The  table contents   are  displayed  in the   table data   panel
             located in the lower left corner of the main window.
             FSC Data: The resonance curve of one scan cycle of the frequency sweep is displayed
             in the graphic  panel.   The  red square   indicates  the  resonance   peak    which  has   been
             found by the on-board S/W within the current scan cycle. General frequency scan cycle
             attributes (row  prefix)  are displayed in  the  data file attribute panel.   If more than   one
             frequency sweep record is stored in the selected data file, the plot parameter drop-list
             can be used to navigate through the records.
             HK1, HK2 Data: Housekeeping data parameters are plotted in the graphic panel. The
             parameters can be selected from the plot parameter drop-list. Due to the rather poor
             performance of the 3rd party S/W for reading and validating the PDS labels, loading of
             the extended housekeeping data (HK2) might take some time.
             IMG Data: Images are displayed in the graphic panel.
             LIN Data: Line scans are displayed in the graphic panel. General line scan attributes
             (row  prefix) are displayed   in the data  file attribute panel. If  more  than   one line  scan
             record is stored in the selected data file, the plot parameter drop-list can be used to
             navigate through the records.
             SPA, SPS Data: Single point scans are displayed in the graphic panel. General single
             point scan attributes (row prefix) are displayed in the data file attribute panel. If more
             than one single point scan record is stored in the selected data file, the plot parameter
             drop-list can be used to navigate through the records.

5.2   Program Source Files

5.2.1  MIDAS Data Set Browser

      The MIDAS Data Set Browser comprises the following IDL source modules:
             error_msg - utility for printing error messages
             escape.pro - utility for handling escape sequences in strings
             ini_file.pro - utility for saving and restoring program settings
             mid_browse.pro - the MIDAS Data Set Browser main program
             release.pro - MIDAS Data Set Browser software revision
             tostr.pro - extended string conversion (e.g. date values)
                                                                Document No.       : MID-IWF-TN-0087
                   ROSETTA-MIDAS to PSA                         Issue/Rev. No.     : 2.0
                   Interface Control Document                   Date               : 16 November 2017
                                                                Page               : 117

5.2.2  Small Bodies Node (SBN) PDS Library

      The READPDS    library was  created at the     Small Bodies Node  (SBN)     of the Planetary Data
      System (PDS) to read PDS image and data files. The release provided in the archive is version
      4.9 dating from 2016-03-02.

      The library consists of the following modules:
             addeobj.pro - insert END_OBJECT keyword if not present and pad lines to 80 bytes
             apply_bitmask.pro - applies bitmask on integer arrays or scalars
             arr_struct.pro - populates an IDL structure for array object to be read
             arrcol_struct.pro - construct an IDL structure for a given array or collection
             arrcolascpds.pro - read a PDS ASCII array or collection object into an IDL structure
             arrcolpds.pro - read a PDS binary array or collection object into an IDL structure
             btabvect2.pro - convert NxM dimensional column vector into IDL data type
             clean.pro - remove all unprintable characters from a string
             cleanarr.pro - remove all unprintable characters from a string array
             coll_struct.pro - populates an IDL structure for collection object to be read
             elem_struct.pro - populates an IDL structure for element object to be read
             get_index.pro - retrieves viable END_OBJECT index position in a PDS label
             headpds.pro - read a PDS label into an array variable
             histogram.pro - read and display PDs histogram objects
             imagepds.pro - read an image array into an array variable
             objpds.pro - obtain viable data objects from a PDS label
             pdspar.pro - obtain the value of a parameter in a PDS header
             pointpds.pro - retrieves pointer information for PDS object from label
             qubepds.pro - read a 3D image qube object into a 3D IDL array
             readhistory.pro - read a history object into a string array variable
             readpds.pro - reads a PDS file into IDL data and label variables
             readspreadsheet.pro - read a PDS spreadsheet object into an IDL structure
             remove_chars.pro - remove all specified characters from a string
             str2num.pro - returns numeric value of a string
             tascpds.pro - read a PDS ASCII table into an IDL structure
             tbinpds.pro - read a PDS binary table file into an IDL structure
             timepds.pro - extract time from PDS label or ASCII table
                                                                     Document No.        : MID-IWF-TN-0087
                      ROSETTA-MIDAS to PSA                           Issue/Rev. No.      : 2.0
                      Interface Control Document                     Date                : 16 November 2017
                                                                     Page                : 118

6  Appendix: Example of Directory Listing of Data Set X

       [TOP-LEVEL-DIRECTORY]
       |
       |--  .PDSVOLUME.XML           Archive  data  file   catalog  generated   by  PVV.
       |--  AAREADME.TXT             Overview  description    of the  data  set   contents.
       |--  VOLDESC.CAT              Description   of  the contents   of  this  volume.
       |
       |--[CALIB]                    Directory   containing   PDS  calibration    objects.
       |  |
       |  |--  CALINFO.TXT           Description   of  files  in the  CALIB   directory.
       |  |--  MIDCALIB.LBL          PDS label   describing   the  MIDAS  calibration    table.
       |  +--  MIDCALIB.TAB          Standard  MIDAS   calibration   table  in  ASCII   format.
       |
       |--[CATALOG]                  Directory   containing   PDS  catalog   objects.
       |  |
       |  |--  CATINFO.TXT           Description   of  files  in the  CATALOG   directory.
       |  |--  DATASET.CAT           Description   of  the MIDAS   data  set.
       |  |--  INST.CAT              Description   of  the MIDAS   instrument.
       |  |--  INSTHOST.CAT          Description   of  the ROSETTA   spacecraft.
       |  |--  MISSION.CAT           Description   of  the ROSETTA   mission.
       |  |--  REFERENCE.CAT         List  of publications    mentioned   in  catalog   files.
       |  |--  SOFTWARE.CAT          Description   of  provided  S/W  to  read  the  data  set.
       |  +--  TARGET.CAT            Description   of  the ROSETTA   mission   targets.
       |
       |--[DATA]                     Directory   containing   the  MIDAS  data  files.
       |  |
       |  |--[EVN]                   Directory   containing   MIDAS  event  data.
       |  |   |
       |  |   |--  *.LBL             Detached  label   files  describing    the data.
       |  |   +--  *.TAB             MIDAS  event  data  files  in  ASCII  format.
       |  |
       |  |--[FSC]                   Directory   containing   MIDAS  frequency    scan  data.
       |  |   |
       |  |   |--  *.LBL             Detached  label   files  describing   the  data.
       |  |   +--  *.TAB             MIDAS  frequency   scan  data  files   in binary   format.
       |  |
       |  |--[HK1]                   Directory   containing   MIDAS  standard   HK  data.
       |  |   |
       |  |   |--  *.LBL             Detached  label   files  describing   the  data.
       |  |   +--  *.TAB             MIDAS  standard   HK data  files   in  binary  format.
       |  |
       |  |--[HK2]                   Directory   containing   MIDAS  extended   HK  data.
       |  |   |
       |  |   |--  *.LBL             Detached  label   files  describing   the  data.
       |  |   +--  *.TAB             MIDAS  extended   HK data  files  in  binary   format.
       |  |
       |  |--[IMG]                   Directory   containing   MIDAS  image  data.
       |  |   |
       |  |   |--  *.LBL             Detached  label   files  describing   the  data.
       |  |   +--  *.BCR             MIDAS  image  data  files  in  STM-BCR   format.
       |  |
       |  |--[LIN]                   Directory   containing   MIDAS  line   scan  data.
       |  |   |
       |  |   |--  *.LBL             Detached  label   files  describing   the  data.
       |  |   +--  *.TAB             MIDAS  line  scan  data  files  in  binary   format.
       |  |
       |  |--[ROI]                   Directory   containing   MIDAS  feature   vector   data.
       |  |   |
       |  |   |--  *.LBL             Detached  label   files  describing   the  data.
       |  |   +--  *.TAB             MIDAS  feature  vector   data  files  in  binary   format.
       |  |
       |  |--[SPA]                   Directory   containing   MIDAS  DAQ  approach   data.
       |  |   |
       |  |   |--  *.LBL             Detached  label   files  describing    the data.
       |  |   +--  *.TAB             MIDAS  DAQ  approach  data  files   in binary   format.
       |  |
       |  |--[SPS]                   Directory   containing   MIDAS  DAQ  sampling   data.
       |  |   |
       |  |   |--  *.LBL             Detached  label   files  describing   the  data.
       |  |   +--  *.TAB             MIDAS  DAQ  sampling  data  files   in binary   format.
                                                               Document No.       : MID-IWF-TN-0087
               ROSETTA-MIDAS to PSA                            Issue/Rev. No.     : 2.0
               Interface Control Document                      Date               : 16 November 2017
                                                               Page               : 119

|  |
|  |--  CAH*.TAB              MIDAS  cantilever   history   files  in ASCII   format.
|  |--  TGH*.TAB              MIDAS  target  history   files  in  ASCII  format.
|  +--  *.LBL                 Detached  label   files  describing    the data.
|
|--[DOCUMENT]                 Directory   containing   volume  related   documents.
|  |
|  |--[CODE]                  Directory   containing   data  browser  S/W   modules.
|  |   |
|  |   |--  MID_BROWSE.LBL    PDS label   describing   the  software  modules.
|  |   |--  MID_BROWSE.PRO    MIDAS  data  browser  main  program   (IDL).
|  |   +--  *.PRO             MIDAS  data  browser  S/W  source   modules   (IDL).
|  |
|  |--  DOCINFO.TXT           Description   of  files  in the  DOCUMENT   directory.
|  |--  MID_*.LBL             PDS labels   for  documents.
|  |--  MID_EICD.TXT          MIDAS  to PSA  interface   document   in  ASCII  format.
|  |--  MID_EICD.PDF          MIDAS  to PSA  interface   document   in  PDF  format.
|  |--  MID_EICD_*.PNG        MIDAS  to PSA  I/F  document   images  in  PDS  format.
|  |--  MID_SSRV.TXT          MIDAS  instrument   paper  in  ASCII  format.
|  |--  MID_SSRV.PDF          MIDAS  instrument   paper  in  Adobe  PDF  format.
|  |--  MID_SSRV_*.PNG        MIDAS  instrument   paper  images   in PNG  format.
|  |--  MID_USER.TXT          MIDAS  user  manual  in  ASCII   format.
|  |--  MID_USER.PDF          MIDAS  user  manual  in  Adobe  PDF  format.
|  +--  MID_USER_*.PNG        MIDAS  user  manual  images   in PNG  format.
|
+--[INDEX]                    Directory   containing   index  files.
   |
   |--  INDXINFO.TXT          Description   of  files  in the   INDEX  directory.
   |--  INDEX.TAB             Index  table  of  MIDAS  data  in this  data   set.
   +--  INDEX.LBL             PDS label   for INDEX.TAB   file.