/* FILE_CONTENTS = SESAME Health Check */ /* Flight software FM3, CODMAC level 3 */ /* FILE_NAME = SESAME_HC_FM3.FMT */ /* REVISION_NOTE = SESAME/DIM team, version 1, 2015-11-04 */ /* K. Seidensticker, version 2, 2015-11-04 */ /* W. Schmidt, version 4, 2015-11-11 */ OBJECT = COLUMN NAME = "UTC" DATA_TYPE = TIME START_BYTE = 1 BYTES = 23 DESCRIPTION = "Measurement start time (UTC in PDS standard format YYYY-MM-DDThh:mm:ss.sss)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SESAME_LOCAL_TIME" DATA_TYPE = ASCII_INTEGER START_BYTE = 25 BYTES = 15 FORMAT = "I15" DESCRIPTION = "Measurement start time. SESAME local time (SLT) runs with a resolution of 1/32 seconds. SLT represents the least significant 32 bits of LOBT. The most significant 5 bits are in CDMS RSST (see SESAME Ready Message)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "U+05" DATA_TYPE = ASCII_REAL START_BYTE = 41 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Common electronics +5V voltage" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "U-05" DATA_TYPE = ASCII_REAL START_BYTE = 50 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Common electronics -5V voltage" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "U+12" DATA_TYPE = ASCII_REAL START_BYTE = 59 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Common electronics +12V voltage" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "U-12" DATA_TYPE = ASCII_REAL START_BYTE = 68 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Common electronics -12V voltage" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "U+28" DATA_TYPE = ASCII_REAL START_BYTE = 77 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Common electronics +28V voltage" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "UCDP" DATA_TYPE = ASCII_REAL START_BYTE = 86 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Common electronics Common DPU +5V voltage" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "I+05" DATA_TYPE = ASCII_REAL START_BYTE = 95 BYTES = 8 FORMAT = "F8.3" UNIT = "MILLIAMPERE" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Common electronics +5V current" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "I-05" DATA_TYPE = ASCII_REAL START_BYTE = 104 BYTES = 8 FORMAT = "F8.3" UNIT = "MILLIAMPERE" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Common electronics -5V current" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "I+12" DATA_TYPE = ASCII_REAL START_BYTE = 113 BYTES = 8 FORMAT = "F8.3" UNIT = "MILLIAMPERE" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Common electronics +12V current" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "I-12" DATA_TYPE = ASCII_REAL START_BYTE = 122 BYTES = 8 FORMAT = "F8.3" UNIT = "MILLIAMPERE" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Common electronics -12V current" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "I+28" DATA_TYPE = ASCII_REAL START_BYTE = 131 BYTES = 8 FORMAT = "F8.3" UNIT = "MILLIAMPERE" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Common electronics +28V current" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SUPS" DATA_TYPE = ASCII_INTEGER START_BYTE = 140 BYTES = 8 UNIT = "N/A" MISSING_CONSTANT = 16#FFFF# DESCRIPTION = "Common electronics; SRAM usage/ power status (hex value as 16#xxxx#)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TIBO" DATA_TYPE = ASCII_INTEGER START_BYTE = 149 BYTES = 6 FORMAT = "I6" UNIT = "SECOND" MISSING_CONSTANT = 999999 DESCRIPTION = "Common electronics Time since boot" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "ERRF" DATA_TYPE = ASCII_INTEGER START_BYTE = 156 BYTES = 8 UNIT = "N/A" MISSING_CONSTANT = 16#FFFF# DESCRIPTION = "Common electronics Error flags (hex value as 16#xxxx#)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CEID" DATA_TYPE = ASCII_INTEGER START_BYTE = 165 BYTES = 8 UNIT = "N/A" MISSING_CONSTANT = 16#FFFF# DESCRIPTION = "Common electronics; SESAME flight software ID (hex value, FM3: 16#C5E5#)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CLTC" DATA_TYPE = ASCII_INTEGER START_BYTE = 174 BYTES = 8 UNIT = "N/A" MISSING_CONSTANT = 16#FFFF# DESCRIPTION = "Common electronics; Last received TC (hex value as 16#xxxx#)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CBTC" DATA_TYPE = ASCII_INTEGER START_BYTE = 183 BYTES = 8 UNIT = "N/A" MISSING_CONSTANT = 16#FFFF# DESCRIPTION = "Common electronics; Last but one TC (hex value as 16#xxxx#)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TT-Y" DATA_TYPE = ASCII_REAL START_BYTE = 192 BYTES = 8 FORMAT = "F8.3" UNIT = "KELVIN" MISSING_CONSTANT = 9999.999 DESCRIPTION = "CASSE Foot -Y/TRM temperature" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TA-Y" DATA_TYPE = ASCII_REAL START_BYTE = 201 BYTES = 8 FORMAT = "F8.3" UNIT = "KELVIN" MISSING_CONSTANT = 9999.999 DESCRIPTION = "CASSE Foot -Y/ACC temperature" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TT+X" DATA_TYPE = ASCII_REAL START_BYTE = 210 BYTES = 8 FORMAT = "F8.3" UNIT = "KELVIN" MISSING_CONSTANT = 9999.999 DESCRIPTION = "CASSE Foot +X/TRM temperature" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TA+X" DATA_TYPE = ASCII_REAL START_BYTE = 219 BYTES = 8 FORMAT = "F8.3" UNIT = "KELVIN" MISSING_CONSTANT = 9999.999 DESCRIPTION = "CASSE Foot +X/ACC temperature" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TT+Y" DATA_TYPE = ASCII_REAL START_BYTE = 228 BYTES = 8 FORMAT = "F8.3" UNIT = "KELVIN" MISSING_CONSTANT = 9999.999 DESCRIPTION = "CASSE Foot +Y/TRM temperature" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TA+Y" DATA_TYPE = ASCII_REAL START_BYTE = 237 BYTES = 8 FORMAT = "F8.3" UNIT = "KELVIN" MISSING_CONSTANT = 9999.999 DESCRIPTION = "CASSE Foot +Y/ACC temperature" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TPCB" DATA_TYPE = ASCII_REAL START_BYTE = 246 BYTES = 8 FORMAT = "F8.3" UNIT = "KELVIN" MISSING_CONSTANT = 9999.999 DESCRIPTION = "CASSE board temperature" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "UFPG" DATA_TYPE = ASCII_REAL START_BYTE = 255 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "CASSE FPGA 3.3V voltage" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "URAD" DATA_TYPE = ASCII_REAL START_BYTE = 264 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "CASSE total dose (RadFET)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "UD+5" DATA_TYPE = ASCII_REAL START_BYTE = 273 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "DIM +5V voltage" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "UD-5" DATA_TYPE = ASCII_REAL START_BYTE = 282 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "DIM -5V voltage" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "UP+5" DATA_TYPE = ASCII_REAL START_BYTE = 291 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "PP +5V voltage" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PPD" DATA_TYPE = ASCII_INTEGER START_BYTE = 300 BYTES = 5 FORMAT = "I5" UNIT = "N/A" MISSING_CONSTANT = 99999 DESCRIPTION = "PP electron density" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LMID" DATA_TYPE = ASCII_INTEGER START_BYTE = 306 BYTES = 5 FORMAT = "I5" MISSING_CONSTANT = 99999 DESCRIPTION = "Common electronics SLT mid word" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LLOW" DATA_TYPE = ASCII_INTEGER START_BYTE = 312 BYTES = 5 FORMAT = "I5" MISSING_CONSTANT = 99999 DESCRIPTION = "Common electronics SLT low word" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-HK_CHANNEL1" DATA_TYPE = ASCII_REAL START_BYTE = 318 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Voltage of temperature channel using regular HK measurement, for Foot -Y/TRM" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-I1_CHANNEL1" DATA_TYPE = ASCII_REAL START_BYTE = 327 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Intermediate voltage measured shortly after switching from temperature channel to reference channel 1, for Foot -Y/TRM" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-R1_CHANNEL1" DATA_TYPE = ASCII_REAL START_BYTE = 336 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Voltage of reference channel 1 = UCDP, for Foot -Y/TRM" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-I2_CHANNEL1" DATA_TYPE = ASCII_REAL START_BYTE = 345 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Intermediate voltage measured shortly after switching from temperature channel to reference channel 2, for Foot -Y/TRM" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-R2_CHANNEL1" DATA_TYPE = ASCII_REAL START_BYTE = 354 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Voltage of reference channel 2 = U + 28, for Foot -Y/TRM" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-HK_CHANNEL2" DATA_TYPE = ASCII_REAL START_BYTE = 363 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Voltage of temperature channel using regular HK measurement, for Foot -Y/ACC" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-I1_CHANNEL2" DATA_TYPE = ASCII_REAL START_BYTE = 372 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Intermediate voltage measured shortly after switching from temperature channel to reference channel 1, for Foot -Y/ACC" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-R1_CHANNEL2" DATA_TYPE = ASCII_REAL START_BYTE = 381 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.99 DESCRIPTION = "voltage of reference channel 1 = UCDP, for Foot -Y/ACC" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-I2_CHANNEL2" DATA_TYPE = ASCII_REAL START_BYTE = 390 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Intermediate voltage measured shortly after switching from temperature channel to reference channel 2, for Foot -Y/ACC" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-R2_CHANNEL2" DATA_TYPE = ASCII_REAL START_BYTE = 399 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Voltage of reference channel 2 = U + 28, for Foot -Y/ACC" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-HK_CHANNEL3" DATA_TYPE = ASCII_REAL START_BYTE = 408 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Voltage of temperature channel using regular HK measurement, for Foot +X/TRM" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-I1_CHANNEL3" DATA_TYPE = ASCII_REAL START_BYTE = 417 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Intermediate voltage measured shortly after switching from temperature channel to reference from temperature channel to reference channel 1, for Foot +X/TRM" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-R1_CHANNEL3" DATA_TYPE = ASCII_REAL START_BYTE = 426 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Voltage of reference channel 1 = UCDP, for Foot +X/TRM" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-I2_CHANNEL3" DATA_TYPE = ASCII_REAL START_BYTE = 435 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Intermediate voltage measured shortly after switching from temperature channel to reference channel 2, for Foot +X/TRM" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-R2_CHANNEL3" DATA_TYPE = ASCII_REAL START_BYTE = 444 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Voltage of reference channel 2 = U + 28, for Foot +X/TRM" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-HK_CHANNEL4" DATA_TYPE = ASCII_REAL START_BYTE = 453 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Voltage of temperature channel using regular HK measurement, for Foot +X/ACC" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-I1_CHANNEL4" DATA_TYPE = ASCII_REAL START_BYTE = 462 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Intermediate voltage measured shortly after switching from temperature channel to reference channel 1, for Foot +X/ACC" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-R1_CHANNEL4" DATA_TYPE = ASCII_REAL START_BYTE = 471 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Voltage of reference channel 1 = UCDP, for Foot +X/ACC" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-I2_CHANNEL4" DATA_TYPE = ASCII_REAL START_BYTE = 480 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Intermediate voltage measured shortly after switching from temperature channel to reference channel 2, for Foot +X/ACC" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-R2_CHANNEL4" DATA_TYPE = ASCII_REAL START_BYTE = 489 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Voltage of reference channel 2 = U + 28, for Foot +X/ACC" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-HK_CHANNEL5" DATA_TYPE = ASCII_REAL START_BYTE = 498 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Voltage of temperature channel using regular HK measurement, for Foot +Y/TRM" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-I1_CHANNEL5" DATA_TYPE = ASCII_REAL START_BYTE = 507 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Intermediate voltage measured shortly after switching from temperature channel to reference channel 1, for Foot +Y/TRM" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-R1_CHANNEL5" DATA_TYPE = ASCII_REAL START_BYTE = 516 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Voltage of reference channel 1 = UCDP, for Foot +Y/TRM" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-I2_CHANNEL5" DATA_TYPE = ASCII_REAL START_BYTE = 525 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Intermediate voltage measured shortly after switching from temperature channel to reference channel 2, for Foot +Y/TRM" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-R2_CHANNEL5" DATA_TYPE = ASCII_REAL START_BYTE = 534 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Voltage of reference channel 2 = U + 28, for Foot +Y/TRM" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-HK_CHANNEL6" DATA_TYPE = ASCII_REAL START_BYTE = 543 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Voltage of temperature channel using regular HK measurement, for Foot +Y/ACC" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-I1_CHANNEL6" DATA_TYPE = ASCII_REAL START_BYTE = 552 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Intermediate voltage measured shortly after switching from temperature channel to reference channel 1, for Foot +Y/ACC" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-R1_CHANNEL6" DATA_TYPE = ASCII_REAL START_BYTE = 561 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Voltage of reference channel 1 = UCDP, for Foot +Y/ACC" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-I2_CHANNEL6" DATA_TYPE = ASCII_REAL START_BYTE = 570 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Intermediate voltage measured shortly after switching from temperature channel to reference channel 2, for Foot +Y/ACC" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-R2_CHANNEL6" DATA_TYPE = ASCII_REAL START_BYTE = 579 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Voltage of reference channel 2 = U + 28, for Foot +Y/ACC" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-HK_CHANNEL7" DATA_TYPE = ASCII_REAL START_BYTE = 588 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Voltage of temperature channel using regular HK measurement, for CASSE PCB temperature" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-I1_CHANNEL7" DATA_TYPE = ASCII_REAL START_BYTE = 597 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Intermediate voltage measured shortly after switching from temperature channel to reference channel 1, for CASSE PCB temperature" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-R1_CHANNEL7" DATA_TYPE = ASCII_REAL START_BYTE = 606 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Voltage of reference channel 1 = UCDP, for CASSE PCB temperature" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-I2_CHANNEL7" DATA_TYPE = ASCII_REAL START_BYTE = 615 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Intermediate voltage measured shortly after switching from temperature channel to reference channel 2, for CASSE PCB temperature" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "T-R2_CHANNEL7" DATA_TYPE = ASCII_REAL START_BYTE = 624 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "Voltage of reference channel 2 = U + 28, for CASSE PCB temperature" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "URAD-2" DATA_TYPE = ASCII_REAL START_BYTE = 633 BYTES = 8 FORMAT = "F8.3" UNIT = "VOLT" MISSING_CONSTANT = 9999.999 DESCRIPTION = "CASSE total dose (RadFET), second measurement" END_OBJECT = COLUMN