OBJECT = COLUMN NAME = "SESAME_SEQ_ID" DATA_TYPE = ASCII_INTEGER START_BYTE = 1 BYTES = 6 FORMAT = "I6" UNIT = "N/A" DESCRIPTION = "Sequence ID in the current data file" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "JOB_ID" DATA_TYPE = CHARACTER START_BYTE = 9 BYTES = 2 FORMAT = "A2" UNIT = "N/A" DESCRIPTION = "Jobcard identifier (hex value)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "JOB_VERSION" DATA_TYPE = CHARACTER START_BYTE = 14 BYTES = 1 FORMAT = "A1" UNIT = "N/A" DESCRIPTION = "The possible values are: 0 for FM-1 and FM-2 B for FM-3" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "NMEAS" DATA_TYPE = ASCII_INTEGER START_BYTE = 17 BYTES = 3 FORMAT = "I3" UNIT = "N/A" DESCRIPTION = "Number of measurements (1 to 127)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "STACK" DATA_TYPE = CHARACTER START_BYTE = 22 BYTES = 3 FORMAT = "A3" UNIT = "N/A" DESCRIPTION = "Indicates that the time series shall be stacked on board. The possible values are YES or NO." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SOUND_FREQ" DATA_TYPE = ASCII_INTEGER START_BYTE = 27 BYTES = 5 FORMAT = "I5" UNIT = "HERTZ" DESCRIPTION = "Nominal sounding frequency" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SND_DURATION" DATA_TYPE = ASCII_REAL START_BYTE = 33 BYTES = 9 FORMAT = "F9.1" UNIT = "MILLISECOND" MISSING_CONSTANT = 9999999.9 DESCRIPTION = "Sounding duration in sounding mode" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TRIGGER_TIMEOUT" DATA_TYPE = ASCII_INTEGER START_BYTE = 43 BYTES = 5 FORMAT = "I5" UNIT = "SECOND" MISSING_CONSTANT = 99999 DESCRIPTION = "Time-out duration, after which listening stops if no trigger signal occurred" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SAMPLING_FREQ" DATA_TYPE = ASCII_INTEGER START_BYTE = 49 BYTES = 6 FORMAT = "I6" UNIT = "HERTZ" DESCRIPTION = "Sampling frequency per channel" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TX_STATUS" DATA_TYPE = CHARACTER START_BYTE = 57 BYTES = 5 FORMAT = "A5" UNIT = "N/A" DESCRIPTION = "Selection of transmitters to be used in Sounding Mode. If TX_cycle is set, after a measurement the transmitter selection is (cyclically) shifted by one position up to yield the transmitters to be used for the next measurement. If Tx_reverse is additionally set, the selection of active transmitters is shifted one position downwards instead. Bit field represented as 5 characters, the rightmost character corresponds to bit #0 and the leftmost to bit #4. Each character can be 1 (active sensor or cycle on or reversed on) or 0 (sensor not used) and have the following meaning: bit 0: TRM -Y bit 1: TRM +X bit 2: TRM +Y bit 3: TX_cycle bit 4: TX_reverse" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "AGC" DATA_TYPE = CHARACTER START_BYTE = 65 BYTES = 2 FORMAT = "A2" UNIT = "N/A" DESCRIPTION = "Amplification gain selection (hex value) Value to be written to the Amplifier Gain Control register of CASSE electronics. Decimal value ranges from 0 (maximal gain) to 15 (minimal gain). Note (a) the gain is not a monotone function of the AGC value, (b) the actually adjusted gain can deviate, if automatic gain setting (AGS) is enabled." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TRIGGER_SRC" DATA_TYPE = CHARACTER START_BYTE = 70 BYTES = 12 FORMAT = "A12" UNIT = "N/A" DESCRIPTION = "Subset of active sensor channels used as trigger sources. Bit field represented as 12 characters, the rightmost character corresponds to bit #0 and the leftmost to bit #11. Each character can be 1 (active sensor used as a trigger source) or 0 (sensor not used as a trigger source) and have the following meaning: bit 0: ACC -Y, x-axis bit 1: ACC -Y, y-axis bit 2: ACC -Y, z-axis bit 3: ACC +X, x-axis bit 4: ACC +X, y-axis bit 5: ACC +X, z-axis bit 6: ACC +Y, x-axis bit 7: ACC +Y, y-axis bit 8: ACC +Y, z-axis bit 9: TRM -Y bit 10: TRM +X bit 11: TRM +Y" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TRIGGER_DELAY" DATA_TYPE = ASCII_REAL START_BYTE = 84 BYTES = 9 FORMAT = "F9.1" UNIT = "MILLISECOND" DESCRIPTION = "Determines the time range before (negative value) or after (positive value) a trigger event, which shall be included in the time series. Absolute value of TrgDelay must be less or equal LIS_DURATION." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TRIGGER_LEVEL_POS" DATA_TYPE = ASCII_INTEGER START_BYTE = 94 BYTES = 4 FORMAT = "I4" UNIT = "N/A" DESCRIPTION = "Positive trigger level. Value to be written to the UTT hardware register, which fixes the upper (always positive) trigger threshold. Note that the actually adjusted value can be different, if automatic trigger level setting is enabled." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TRIGGER_LEVEL_NEG" DATA_TYPE = ASCII_INTEGER START_BYTE = 99 BYTES = 4 FORMAT = "I4" UNIT = "N/A" DESCRIPTION = "Negative trigger level. Value to be written to the LTT hardware register, which fixes the lower (always negative) trigger threshold. Note that the actually adjusted value can be different, if automatic trigger level setting is enabled." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LIS_DURATION" DATA_TYPE = ASCII_REAL START_BYTE = 104 BYTES = 9 FORMAT = "F9.1" UNIT = "MILLISECOND" DESCRIPTION = "Listening duration" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RX_STATUS" DATA_TYPE = CHARACTER START_BYTE = 115 BYTES = 14 FORMAT = "A14" UNIT = "N/A" DESCRIPTION = "Selection of sensor channels to be used. If cycle is set, after a measurement the receiver selection is (cyclically) shifted by one position (in the same direction as the transmitters, as indicated in TX_STATUS. If the reversed flag is additionally set, the receiver cycling shall take place in the opposite direction as the transmitter cycling. Bit field represented as 15 characters, the rightmost character corresponds to bit #0 and the leftmost to bit #13. Each character can be 1 (active sensor or cycle on or reversed on) or 0 (sensor not used) and have the following meaning: bit 0: ACC -Y, x-axis bit 1: ACC -Y, y-axis bit 2: ACC -Y, z-axis bit 3: ACC +X, x-axis bit 4: ACC +X, y-axis bit 5: ACC +X, z-axis bit 6: ACC +Y, x-axis bit 7: ACC +Y, y-axis bit 8: ACC +Y, z-axis bit 9: TRM -Y bit 10: TRM +X bit 11: TRM +Y bit 12: cycle bit 13: reversed" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "G_GEN" DATA_TYPE = ASCII_INTEGER START_BYTE = 131 BYTES = 1 FORMAT = "I1" UNIT = "N/A" DESCRIPTION = "Values 1 or 0 1: prepare data for automatic gain adjustment" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "G_COMP" DATA_TYPE = ASCII_INTEGER START_BYTE = 133 BYTES = 1 FORMAT = "I1" UNIT = "N/A" DESCRIPTION = "0: Do not calculate optimized gain 1: Optimize for lower 1/3 of channels 2: Optimize for lower 2/3 of channels 3: Optimize for strongest channel" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TL_GEN" DATA_TYPE = ASCII_INTEGER START_BYTE = 135 BYTES = 1 FORMAT = "I1" UNIT = "N/A" DESCRIPTION = "Values 1 or 0 1: prepare data for automatic trigger level adjustment" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TL_COMP" DATA_TYPE = ASCII_INTEGER START_BYTE = 137 BYTES = 1 FORMAT = "I1" UNIT = "N/A" DESCRIPTION = "Values 1 or 0 1: adjust optimized trigger levels" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "STATS" DATA_TYPE = ASCII_INTEGER START_BYTE = 139 BYTES = 1 FORMAT = "I1" UNIT = "N/A" DESCRIPTION = "Values 1 or 0 1: include channels statistics for each measurement" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SKIP_TS" DATA_TYPE = ASCII_INTEGER START_BYTE = 141 BYTES = 1 FORMAT = "I1" UNIT = "N/A" DESCRIPTION = "Values 1 or 0 If 1 time series not included into telemetry (ignored in Stacking Mode)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "G_TAR_VAL" DATA_TYPE = ASCII_INTEGER START_BYTE = 143 BYTES = 3 FORMAT = "I3" UNIT = "N/A" DESCRIPTION = "Target value for automatic gain adjustment. Linearized ADC units in the range 1 to 255. In combination with the value of G_COMP, gain is adjusted such that the absolute values of the samples of 1/3, 2/3 or all channels are close to, but below, G_TAR_VAL." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TL_FACTOR" DATA_TYPE = ASCII_INTEGER START_BYTE = 147 BYTES = 4 FORMAT = I4 UNIT = "N/A" DESCRIPTION = "Factor for calculating the trigger levels from 10 to 2550%. Distance of trigger level from mean of time series (of selected trigger channels) relative to the distance between mean and the extreme sample values; TL_FACTOR equals 10 (100 %) means that trigger level are set equal to the maximum deviation from mean during the pre-measurement. A TLFactor value less than or equal 10 would have caused a trigger signal during the pre-measurement. For each sensor channel marked as trigger channel, flight software calculates preliminary trigger levels based on statistical values (Max, Min, Mean) of a pre-measurement with trglevneg = (Min-Mean) * TLFactor / 10 + Mean trglevpos = (Max-Mean) * TLFactor / 10 + Mean The smallest value of the trglevneg obtained this way is adjusted as negative trigger level (TrgLevNeg), and the highest trglevpos as positive trigger level (TrgLevPos), possible after correcting different gain settings during the pre-measurement and the Trigger Mode measurement." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "AMP_SETUP" DATA_TYPE = ASCII_REAL START_BYTE = 152 BYTES = 4 FORMAT = "F4.1" UNIT = "SECOND" DESCRIPTION = "Amplifier setup time in sounding mode. It represents the Duration after start of time series recording used for amplifier setup (to yield constant base lines). A value of 1 s should normally be used, because it enables the correct identification of sensor channels for all possible sampling frequencies (no wrap-around of FIFO buffer)." END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FIFO_LAG" DATA_TYPE = ASCII_INTEGER START_BYTE = 157 BYTES = 4 FORMAT = I4 UNIT = "N/A" DESCRIPTION = "Optional corrective offset of the address of the first sample to be transferred. Range from -127 to 127" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "FOOT_TEMP" DATA_TYPE = CHARACTER START_BYTE = 163 BYTES = 7 FORMAT = "A7" UNIT = "N/A" DESCRIPTION = "Active foot temperature channels. Bit field represented as 7 characters, the rightmost character corresponds to bit #0 and the leftmost to bit #6. The Temperature and Radiation Dose Data Block will be generated by flight software, if at least one foot temperature channel is selected in FOOT_TEMP. It will additionally be included at the end of a measuring sequence, if the additional 'after job temperature' flag is set. Each character can be 1 (channel selected) or 0 (channel not selected) and have the following meaning: bit 0: Temperature -Y, TRM bit 1: Temperature -Y, ACC bit 2: Temperature +X, TRM bit 3: Temperature +X, ACC bit 4: Temperature +Y, TRM bit 5: Temperature +Y, ACC bit 6: Additional after job temperatures" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "ADD_DELAY" DATA_TYPE = ASCII_INTEGER START_BYTE = 172 BYTES = 3 UNIT = "SECOND" FORMAT = I3 DESCRIPTION = "Additional delay between measurements of a measurement sequence" END_OBJECT = COLUMN