/* Contents of format file "COSAC_CONFIG_FM1_8.FMT" */ OBJECT = COLUMN NAME = "SD_VERSION_ID" DATA_TYPE = CHARACTER START_BYTE = 2 BYTES = 4 DESCRIPTION = "Science data stream version ID, in hexadecimal format. Forversion V1.8 the value is 0x0180" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TIMEREF_ID" DATA_TYPE = CHARACTER START_BYTE = 9 BYTES = 19 DESCRIPTION = "Used to synchronize LOBT and COBT. The first 8 characters represent the LOBT in hexadecimal (4 bytes) and the last 8 characters represent the COBT (4 bytes). COBT is the Cosac On-Board Time with a resolution of 1ms." END_OBJECT = COLUMN /* TC */ OBJECT = COLUMN NAME = "TC_DATA" DATA_TYPE = CHARACTER START_BYTE = 31 BYTES = 39 DESCRIPTION = "TC data words in hexadecimal format" END_OBJECT = COLUMN /* CSIB_CFG */ /* Configuration data for tapping Station, MS and GC */ /* ------ Configuration data for Tapping Station (30 words) ------ */ OBJECT = COLUMN NAME = "TPST_DIR_CONTRL" DATA_TYPE = CHARACTER START_BYTE = 73 BYTES = 8 UNIT = "N/A" DESCRIPTION = "TPST: Direct controlling, Possible values : disabled enabled" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TPST_POS_INFO" DATA_TYPE = CHARACTER START_BYTE = 84 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) TPST: Position information 0x0000 = LUT , 0xffff = Value" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TPST_POS_ID" DATA_TYPE = CHARACTER START_BYTE = 91 BYTES = 20 UNIT = "N/A" DESCRIPTION = " TPST: Position ID Possible values : Open Contacts closed Main Terminal closed Side Terminal closed Upper position Lower position" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TPST_POS_VALUE" DATA_TYPE = CHARACTER START_BYTE = 114 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) TPST: Position value, potentiometer value" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TPST_DIRECTION" DATA_TYPE = CHARACTER START_BYTE = 121 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) TPST: Direction CS1.D7 = 0000 CS1.D7 = ffff" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TPST_TIME_TO_DRIVE" DATA_TYPE = CHARACTER START_BYTE = 128 BYTES = 4 UNIT = SECOND DESCRIPTION = "(Hexadecimal Format) TPST: Time to drive (sec)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TPST_START_CAL" DATA_TYPE = CHARACTER START_BYTE = 135 BYTES = 5 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) TPST: Start calibration Possible values : False True" END_OBJECT = COLUMN /* ------------- Configuration data for MS (30 words) --------------- */ OBJECT = COLUMN NAME = "MS_HK_SWEEPING" DATA_TYPE = CHARACTER START_BYTE = 143 BYTES = 3 UNIT = "N/A" DESCRIPTION = "MS: HK sweeping Possible values : yes no" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_ACCUMULATE" DATA_TYPE = CHARACTER START_BYTE = 149 BYTES = 3 UNIT = "N/A" DESCRIPTION = "MS: Accumulate parameter ; possible values : yes no" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_CATHODE" DATA_TYPE = ASCII_INTEGER START_BYTE = 154 BYTES = 1 UNIT = "N/A" DESCRIPTION = "MS: Cathode number to be selected" FORMAT = I1 END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_EMI_CURRENT" DATA_TYPE = CHARACTER START_BYTE = 157 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) MS: Emission current" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_DET_VOLT" DATA_TYPE = CHARACTER START_BYTE = 164 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) MS: Detector voltage" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_RESOL" DATA_TYPE = CHARACTER START_BYTE = 171 BYTES = 4 UNIT = "N/A" DESCRIPTION = " MS: Resolution possible values : low high " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_FREQUENCY" DATA_TYPE = ASCII_INTEGER START_BYTE = 177 BYTES = 8 UNIT = "N/A" FORMAT = I8 DESCRIPTION = "MS: Frequency" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_RUN CAL" DATA_TYPE = CHARACTER START_BYTE = 187 BYTES = 5 UNIT = "N/A" DESCRIPTION = "MS: Run calibration Possible values : False True" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_SNIFFING_MODE" DATA_TYPE = CHARACTER START_BYTE = 195 BYTES = 8 UNIT = "N/A" DESCRIPTION = "MS: Sniffing mode Possible values : disabled enabled" END_OBJECT = COLUMN /* ------------- Configuration data for GC (30 words) ------------- */ OBJECT = COLUMN NAME = "GC_HK_SWEEPING" DATA_TYPE = CHARACTER START_BYTE = 206 BYTES = 3 UNIT = "N/A" DESCRIPTION = "GC: HK sweeping Possible values : yes no" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "GC_CONTINUE_FLAG" DATA_TYPE = CHARACTER START_BYTE = 212 BYTES = 5 UNIT = "N/A" DESCRIPTION = "GC: continue flag ; Possible values : False True" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "GC_DUR_MEASURE" DATA_TYPE = ASCII_INTEGER START_BYTE = 219 BYTES = 2 UNIT = "N/A" FORMAT = I2 DESCRIPTION = "GC: Duration of measurement This is an index pointing into a look-up table holding the following values: 1 : 1,12 min 2 : 2,23 min 4 : 4,47 min 8 : 8,95 min 16 : 17,89 min Note that any combination of the above values is possible! 01010 : 8,95 + 2,23 min 10101 : 17,89 + 4,47 + 1,12 min" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "GC_HELIUM_TANK" DATA_TYPE = CHARACTER START_BYTE = 223 BYTES = 6 UNIT = "N/A" DESCRIPTION = "GC: Helium tank selected Possible values : Tank 1 Tank 2" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "GC_DUR_INJEC" DATA_TYPE = ASCII_INTEGER START_BYTE = 231 BYTES = 8 UNIT = MILLISECOND FORMAT = I8 DESCRIPTION = "GC: Duration of injection (msec)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "GC_SAMPLE" DATA_TYPE = CHARACTER START_BYTE = 241 BYTES = 15 UNIT = "N/A" DESCRIPTION = "GC: Sample Possible values : Calibration gas Oven Tenax" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "GC_CHANNEL_1" DATA_TYPE = ASCII_INTEGER START_BYTE = 258 BYTES = 1 UNIT = "N/A" DESCRIPTION = "GC: Column selection for Channel 1 Column #1 0x000i (0 <= i <= 7) Column #2 0x00i0 (0 <= i <= 7) Column #3 0x0i00 (0 <= i <= 7) Column #4 0xi000 (0 <= i <= 7)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "GC_CHANNEL_2" DATA_TYPE = ASCII_INTEGER START_BYTE = 260 BYTES = 1 UNIT = "N/A" DESCRIPTION = "GC: Column selection for Channel 2 Column #1 0x000i (0 <= i <= 7) Column #2 0x00i0 (0 <= i <= 7) Column #3 0x0i00 (0 <= i <= 7) Column #4 0xi000 (0 <= i <= 7)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "GC_CHANNEL_3" DATA_TYPE = ASCII_INTEGER START_BYTE = 262 BYTES = 1 UNIT = "N/A" DESCRIPTION = "GC: Column selection for Channel 3 Column #1 0x000i (0 <= i <= 7) Column #2 0x00i0 (0 <= i <= 7) Column #3 0x0i00 (0 <= i <= 7) Column #4 0xi000 (0 <= i <= 7)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "GC_CHANNEL_4" DATA_TYPE = ASCII_INTEGER START_BYTE = 264 BYTES = 1 UNIT = "N/A" DESCRIPTION = "GC: Column selection for Channel 4 Column #1 0x000i (0 <= i <= 7) Column #2 0x00i0 (0 <= i <= 7) Column #3 0x0i00 (0 <= i <= 7) Column #4 0xi000 (0 <= i <= 7)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "GC_COL_HEAD_PRESS" DATA_TYPE = CHARACTER START_BYTE = 267 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) GC: Column head pressure 0x0000 <= x <= 0x00ff" END_OBJECT = COLUMN /* CSIB_PAR */ /* Device parameters and experiment parameters for MS and GC */ /* --------------- Device parameters (27 words) --------------- */ OBJECT = COLUMN NAME = "TPST_POS_OPEN" DATA_TYPE = ASCII_INTEGER START_BYTE = 273 BYTES = 8 UNIT = "N/A" FORMAT = I8 DESCRIPTION = "TPST: Position Open" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TPST_POS_CONT_CLOS" DATA_TYPE = ASCII_INTEGER START_BYTE = 282 BYTES = 8 UNIT = "N/A" FORMAT = I8 DESCRIPTION = "TPST: Position Contacts Closed" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TPST_POS_MAIN_TERM_CLOS" DATA_TYPE = ASCII_INTEGER START_BYTE = 291 BYTES = 8 UNIT = "N/A" FORMAT = I8 DESCRIPTION = "TPST: Position Main Terminal Closed" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TPST_POS_SIDE_TERM_CLOS" DATA_TYPE = ASCII_INTEGER START_BYTE = 300 BYTES = 8 UNIT = "N/A" FORMAT = I8 DESCRIPTION = "TPST: Position Side Terminal Closed" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TPST_POS_UPPER" DATA_TYPE = ASCII_INTEGER START_BYTE = 309 BYTES = 8 UNIT = "N/A" FORMAT = I8 DESCRIPTION = "TPST: Position Upper" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TPST_POS_LOWER" DATA_TYPE = ASCII_INTEGER START_BYTE = 318 BYTES = 8 UNIT = "N/A" FORMAT = I8 DESCRIPTION = "TPST: Position Lower" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TPST_BACKUP_RAM" DATA_TYPE = CHARACTER START_BYTE = 328 BYTES = 3 UNIT = "N/A" DESCRIPTION = "TPST: Use of Backup Ram ; possible values : yes no" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TPST_IGN_SD2 STAT" DATA_TYPE = CHARACTER START_BYTE = 334 BYTES = 3 UNIT = "N/A" DESCRIPTION = "TPST: Ignore SD2 Status ; possible values : yes no" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TPST_TIMEOUT_VALUE" DATA_TYPE = ASCII_INTEGER START_BYTE = 339 BYTES = 8 UNIT = "MILLISECOND" FORMAT = I8 DESCRIPTION = "TPST: Timeout Value" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TPST_CREATE_REPORT" DATA_TYPE = CHARACTER START_BYTE = 349 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) TPST: Create Report" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEMPERATURE_0" DATA_TYPE = CHARACTER START_BYTE = 356 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) Temperature[0]" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEMPERATURE_1" DATA_TYPE = CHARACTER START_BYTE = 363 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) Temperature[1]" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEMPERATURE_2" DATA_TYPE = CHARACTER START_BYTE = 370 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) Temperature[2]" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEMPERATURE_3" DATA_TYPE = CHARACTER START_BYTE = 377 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) Temperature[3]" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEMPERATURE_4" DATA_TYPE = CHARACTER START_BYTE = 384 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) Temperature[4]" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEMPERATURE_5" DATA_TYPE = CHARACTER START_BYTE = 391 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) Temperature[5]" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEMPERATURE_6" DATA_TYPE = CHARACTER START_BYTE = 398 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) Temperature[6]" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TEMPERATURE_7" DATA_TYPE = CHARACTER START_BYTE = 405 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) Temperature[7]" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "HEATING_TIME_0" DATA_TYPE = CHARACTER START_BYTE = 412 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) Heating Time[0]" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "HEATING_TIME_1" DATA_TYPE = CHARACTER START_BYTE = 419 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) Heating Time[1]" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "HEATING_TIME_2" DATA_TYPE = CHARACTER START_BYTE = 426 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) Heating Time[2]" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "HEATING_TIME_3" DATA_TYPE = CHARACTER START_BYTE = 433 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) Heating Time[3]" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "HEATING_TIME_4" DATA_TYPE = CHARACTER START_BYTE = 440 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) Heating Time[4]" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "HEATING_TIME_5" DATA_TYPE = CHARACTER START_BYTE = 447 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) Heating Time[5]" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "HEATING_TIME_6" DATA_TYPE = CHARACTER START_BYTE = 454 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) Heating Time[6]" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "HEATING_TIME_7" DATA_TYPE = CHARACTER START_BYTE = 461 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) Heating Time[7]" END_OBJECT = COLUMN /* --------------- Experiment parameters MS (18 words) ----------- */ OBJECT = COLUMN NAME = "MS_DURATION" DATA_TYPE = CHARACTER START_BYTE = 468 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) MS: Duration Basically, it is a timing information, but it varies according to the programmed frequency: Bit 1 kHz 4 kHz 3 67,1 s 16,8 s 2 33,5 s 8,4 s 1 16,8 s 4,19 s 0 8,4 s 2,1 s Please note: any combination is possible: 0x7 at 1kHz = 33,5 + 16,8 + 8,4 s 0x7 at 4kHz = 8,4 + 4,19 + 2,1 s" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_USE_AUTO_CAL_VAL" DATA_TYPE = CHARACTER START_BYTE = 475 BYTES = 5 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) MS: Use auto calibration values possible values : True False" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_PRESSURE_CAL_GAS" DATA_TYPE = ASCII_INTEGER START_BYTE = 482 BYTES = 8 UNIT = "N/A" FORMAT = I8 DESCRIPTION = "(Hexadecimal Format) MS: Pressure calibration gas" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_MODE" DATA_TYPE = CHARACTER START_BYTE = 492 BYTES = 6 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) MS: Mode ; possible values : Single Multi" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_GAS_FLOW_DELAY" DATA_TYPE = CHARACTER START_BYTE = 501 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) MS: Gas Flow Delay" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_U_0]" DATA_TYPE = CHARACTER START_BYTE = 508 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) MS: U[0]" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_U_1]" DATA_TYPE = CHARACTER START_BYTE = 515 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) MS: U[1]" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_U_2]" DATA_TYPE = CHARACTER START_BYTE = 522 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) MS: U[2]" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_U_3]" DATA_TYPE = CHARACTER START_BYTE = 529 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) MS: U[3]" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_T_0]" DATA_TYPE = CHARACTER START_BYTE = 536 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) MS: T[0] Counter with 31,25 ms/cnt " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_T_1]" DATA_TYPE = CHARACTER START_BYTE = 543 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) MS: T[1] Counter with 31,25 ms/cnt " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_T_2]" DATA_TYPE = CHARACTER START_BYTE = 550 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) MS: T[2] Counter with 31,25 ms/cnt " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_T_3]" DATA_TYPE = CHARACTER START_BYTE = 557 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) MS: T[3] Counter with 31,25 ms/cnt " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_T_4]" DATA_TYPE = CHARACTER START_BYTE = 564 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) MS: T[4]" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_T_5]" DATA_TYPE = CHARACTER START_BYTE = 571 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) MS: T[5] Counter with 31,25 ms/cnt " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_T_6]" DATA_TYPE = CHARACTER START_BYTE = 578 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) MS: T[6] Counter with 31,25 ms/cnt " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_DET_START_DEL" DATA_TYPE = CHARACTER START_BYTE = 585 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) MS: Detector Start Delay This is an integer with the following bit allocation: Bit Sampling time delay in microseconds 3 256 2 128 1 64 0 32 " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_WORDS_SC_DATA" DATA_TYPE = CHARACTER START_BYTE = 592 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal Format) MS: Words to copy from Science Data" END_OBJECT = COLUMN /* --------------- Experiment parameters GC (10 words) ------------- */ OBJECT = COLUMN NAME = "GC_TEMP_COL_0" DATA_TYPE = ASCII_INTEGER START_BYTE = 598 BYTES = 8 UNIT = "N/A" FORMAT = I8 DESCRIPTION = "GC: Temperature Column 0" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "GC_TEMP_COL_1" DATA_TYPE = ASCII_INTEGER START_BYTE = 607 BYTES = 8 UNIT = "N/A" FORMAT = I8 DESCRIPTION = "GC: Temperature Column 1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "GC_TEMP_COL_2" DATA_TYPE = ASCII_INTEGER START_BYTE = 616 BYTES = 8 UNIT = "N/A" FORMAT = I8 DESCRIPTION = "GC: Temperature Column 2" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "GC_TEMP_COL_3" DATA_TYPE = ASCII_INTEGER START_BYTE = 625 BYTES = 8 UNIT = "N/A" FORMAT = I8 DESCRIPTION = "GC: Temperature Column 3" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "GC_TEMP_COL_4" DATA_TYPE = ASCII_INTEGER START_BYTE = 634 BYTES = 8 UNIT = "N/A" FORMAT = I8 DESCRIPTION = "GC: Temperature Column 4" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "GC_TEMP_COL_5" DATA_TYPE = ASCII_INTEGER START_BYTE = 643 BYTES = 8 UNIT = "N/A" FORMAT = I8 DESCRIPTION = "GC: Temperature Column 5" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "GC_TEMP_COL_6" DATA_TYPE = ASCII_INTEGER START_BYTE = 652 BYTES = 8 UNIT = "N/A" FORMAT = I8 DESCRIPTION = "Temperature Column 6" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "GC_TEMP_COL_7" DATA_TYPE = ASCII_INTEGER START_BYTE = 661 BYTES = 8 UNIT = "N/A" FORMAT = I8 DESCRIPTION = "GC: Temperature Column 7" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "GC_WORDS_SC_DATA" DATA_TYPE = ASCII_INTEGER START_BYTE = 670 BYTES = 8 UNIT = "N/A" FORMAT = I8 DESCRIPTION = "GC: Words to copy from Science Data" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "GC_TIME_TENAX" DATA_TYPE = ASCII_INTEGER START_BYTE = 679 BYTES = 8 UNIT = SECOND FORMAT = I8 DESCRIPTION = "GC: Time to heat Tenax (sec)" END_OBJECT = COLUMN