/* Contents of format file "COSAC_FULL_HK_SC.FMT" */ /* --------------------------------------------------------------- */ /* Values delivered to CDMS (64) */ /* --------------------------------------------------------------- */ /* ................... DPU ............................. */ OBJECT = COLUMN NAME = "P5V_C" DATA_TYPE = ASCII_REAL START_BYTE = 1 BYTES = 8 UNIT = MILLIAMPERE FORMAT = "F8.2" DESCRIPTION = "CURRENT +5V LINE" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "M5V_C" DATA_TYPE = ASCII_REAL START_BYTE = 10 BYTES = 8 FORMAT = "F8.2" UNIT = MILLIAMPERE DESCRIPTION = "CURRENT -5V LINE" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "P12V_C" DATA_TYPE = ASCII_REAL START_BYTE = 19 BYTES = 8 UNIT = MILLIAMPERE FORMAT = "F8.2" DESCRIPTION = "CURRENT +12V LINE" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "M12V_C" DATA_TYPE = ASCII_REAL START_BYTE = 28 BYTES = 8 UNIT = MILLIAMPERE FORMAT = "F8.2" DESCRIPTION = "CURRENT -12V LINE" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SYSTEM_POWER" DATA_TYPE = ASCII_REAL START_BYTE = 37 BYTES = 8 UNIT = WATT FORMAT = "F8.2" DESCRIPTION = "SYSTEM POWER " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "GC_ADC_INPUT" DATA_TYPE = ASCII_INTEGER START_BYTE = 46 BYTES = 8 UNIT = "N/A" FORMAT = "I8" DESCRIPTION = "GC ADC INPUT" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_ADC_INPUT" DATA_TYPE = ASCII_INTEGER START_BYTE = 55 BYTES = 8 UNIT = "N/A" FORMAT = "I8" DESCRIPTION = "MS ADC INPUT" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CHAN7_DPU_MUX" DATA_TYPE = ASCII_INTEGER START_BYTE = 64 BYTES = 8 UNIT = "N/A" FORMAT = "I8" DESCRIPTION = "DPU MUX CHANNEL 7" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CHAN8_DPU_MUX" DATA_TYPE = ASCII_INTEGER START_BYTE = 73 BYTES = 8 UNIT = "N/A" FORMAT = "I8" DESCRIPTION = "DPU MUX CHANNEL 8" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CHAN9_DPU_MUX" DATA_TYPE = ASCII_INTEGER START_BYTE = 82 BYTES = 8 UNIT = "N/A" DESCRIPTION = "DPU MUX CHANNEL 9" FORMAT = "I8" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CHAN10_DPU_MUX" DATA_TYPE = ASCII_INTEGER START_BYTE = 91 BYTES = 8 UNIT = "N/A" FORMAT = "I8" DESCRIPTION = "DPU MUX CHANNEL 10" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CHAN11_DPU_MUX" DATA_TYPE = ASCII_INTEGER START_BYTE = 100 BYTES = 8 UNIT = "N/A" FORMAT = "I8" DESCRIPTION = "DPU MUX CHANNEL 11" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CHAN12_DPU_MUX" DATA_TYPE = ASCII_INTEGER START_BYTE = 109 BYTES = 8 UNIT = "N/A" FORMAT = "I8" DESCRIPTION = "DPU MUX CHANNEL 12 " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CHAN13_DPU_MUX" DATA_TYPE = ASCII_INTEGER START_BYTE = 118 BYTES = 8 UNIT = "N/A" FORMAT = "I8" DESCRIPTION = "DPU MUX CHANNEL 13" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CHAN14_DPU_MUX" DATA_TYPE = ASCII_INTEGER START_BYTE = 127 BYTES = 8 UNIT = "N/A" FORMAT = "I8" DESCRIPTION = "DPU MUX CHANNEL 14" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "DPU_VOLTAGE" DATA_TYPE = ASCII_REAL START_BYTE = 136 BYTES = 8 UNIT = VOLT FORMAT = "F8.2" DESCRIPTION = "VOLTAGE DPU" END_OBJECT = COLUMN /* ................... GC ............................. */ OBJECT = COLUMN NAME = "HE1_PRESSURE" DATA_TYPE = ASCII_INTEGER START_BYTE = 145 BYTES = 10 UNIT = MILLIBAR FORMAT = "I10" DESCRIPTION = "Pressure He Tank 1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "HE2_PRESSURE" DATA_TYPE = ASCII_INTEGER START_BYTE = 156 BYTES = 10 UNIT = MILLIBAR FORMAT = "I10" DESCRIPTION = "Pressure He Tank 2" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "IONS_MS_PRESSURE" DATA_TYPE = ASCII_INTEGER START_BYTE = 167 BYTES = 8 UNIT = "N/A" FORMAT = "I8" DESCRIPTION = "Pressure Ion Source MS" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "GCBOARD2_TEMP" DATA_TYPE = ASCII_REAL START_BYTE = 176 BYTES = 8 UNIT = KELVIN FORMAT = "F8.2" DESCRIPTION = "Temperature GC-Board2 " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TENAX_TEMP" DATA_TYPE = ASCII_REAL START_BYTE = 185 BYTES = 8 UNIT = KELVIN FORMAT = "F8.2" DESCRIPTION = "Temperature Tenax" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "HE_SEC_PRESSURE" DATA_TYPE = ASCII_REAL START_BYTE = 194 BYTES = 8 UNIT = MILLIBAR FORMAT = "F8.2" DESCRIPTION = "Secondary pressure HE)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "VALVE_VOLTAGE" DATA_TYPE = ASCII_REAL START_BYTE = 203 BYTES = 8 UNIT = VOLT FORMAT = "F8.2" DESCRIPTION = "Voltage valve unit" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "COLUMN1_TEMP" DATA_TYPE = ASCII_REAL START_BYTE = 212 BYTES = 8 UNIT = KELVIN FORMAT = "F8.2" DESCRIPTION = "Temperature Column 1)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "COLUMN2_TEMP" DATA_TYPE = ASCII_REAL START_BYTE = 221 BYTES = 8 UNIT = KELVIN FORMAT = "F8.2" DESCRIPTION = "Temperature Column 2" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "COLUMN3_TEMP" DATA_TYPE = ASCII_REAL START_BYTE = 230 BYTES = 8 UNIT = KELVIN FORMAT = "F8.2" DESCRIPTION = "Temperature Column 3" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "COLUMN4_TEMP" DATA_TYPE = ASCII_REAL START_BYTE = 239 BYTES = 8 UNIT = KELVIN FORMAT = "F8.2" DESCRIPTION = "Temperature Column 4" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "COLUMN5_TEMP" DATA_TYPE = ASCII_REAL START_BYTE = 248 BYTES = 8 UNIT = KELVIN FORMAT = "F8.2" DESCRIPTION = "Temperature Column 5" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "COLUMN6_TEMP" DATA_TYPE = ASCII_REAL START_BYTE = 257 BYTES = 8 UNIT = KELVIN FORMAT = "F8.2" DESCRIPTION = "Temperature Column 6" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "COLUMN7_TEMP" DATA_TYPE = ASCII_REAL START_BYTE = 266 BYTES = 8 UNIT = KELVIN FORMAT = "F8.2" DESCRIPTION = "Temperature Column 7" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "COLUMN8_TEMP" DATA_TYPE = ASCII_REAL START_BYTE = 275 BYTES = 8 UNIT = KELVIN FORMAT = "F8.2" DESCRIPTION = "Temperature Column 8)" END_OBJECT = COLUMN /* ................... MS ............................. */ OBJECT = COLUMN NAME = "PIPEA_M_TEMP" DATA_TYPE = ASCII_REAL START_BYTE = 284 BYTES = 8 UNIT = KELVIN FORMAT = "F8.2" DESCRIPTION = "Temperature Pipe a (main)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PIPEB_M_TEMP" DATA_TYPE = ASCII_REAL START_BYTE = 293 BYTES = 8 UNIT = KELVIN FORMAT = "F8.2" DESCRIPTION = "Temperature Pipe b (side)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "OVEN_TEMP" DATA_TYPE = ASCII_REAL START_BYTE = 302 BYTES = 8 UNIT = KELVIN FORMAT = "F8.2" DESCRIPTION = "Temperature Oven" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MSEBOX_TEMP" DATA_TYPE = ASCII_REAL START_BYTE = 311 BYTES = 8 UNIT = KELVIN FORMAT = "F8.2" DESCRIPTION = "Temperature MS-EBox)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CALGAS_PRESSURE" DATA_TYPE = ASCII_INTEGER START_BYTE = 320 BYTES = 8 UNIT = "N/A" FORMAT = "I8" DESCRIPTION = "Pressure Calibration Gas" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TPST_POSITION" DATA_TYPE = ASCII_INTEGER START_BYTE = 329 BYTES = 8 UNIT = "N/A" FORMAT = "I8" DESCRIPTION = "Position Tapping Station Open >= 4500, OT (Oberer Totpunkt/Top dead centre) ~ 4710, UT (Unterer Totpunkt/bottom dead centre) ~ 1330)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "EMISSION_CURRENT" DATA_TYPE = ASCII_REAL START_BYTE = 338 BYTES = 8 UNIT = NANOAMPERE FORMAT = "F8.2" DESCRIPTION = "Emission current" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_HV1_DET_V" DATA_TYPE = ASCII_REAL START_BYTE = 347 BYTES = 8 UNIT = VOLT FORMAT = "F8.2" DESCRIPTION = "MS HV 1, U detector" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_HV2_REFL2_4_V" DATA_TYPE = ASCII_REAL START_BYTE = 356 BYTES = 8 UNIT = VOLT FORMAT = "F8.2" DESCRIPTION = "MS HV 2, U reflector2_4" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_HV3_REFL2_V" DATA_TYPE = ASCII_REAL START_BYTE = 365 BYTES = 8 UNIT = VOLT FORMAT = "F8.2" DESCRIPTION = "MS HV 3, U reflector 2" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_HV4_REFL1_V" DATA_TYPE = ASCII_REAL START_BYTE = 374 BYTES = 8 UNIT = VOLT FORMAT = "F8.2" DESCRIPTION = "MS HV 4, U reflector 1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_HV5_LENSE2_V" DATA_TYPE = ASCII_REAL START_BYTE = 383 BYTES = 8 UNIT = VOLT FORMAT = "F8.2" DESCRIPTION = "MS HV 5, U lense 2" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_HV6_LENSE1_V" DATA_TYPE = ASCII_REAL START_BYTE = 392 BYTES = 8 UNIT = VOLT FORMAT = "F8.2" DESCRIPTION = "MS HV 6, U lense 1" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_HV7_G3_V" DATA_TYPE = ASCII_REAL START_BYTE = 401 BYTES = 8 UNIT = VOLT FORMAT = "F8.2" DESCRIPTION = "MS HV 7, U G3" END_OBJECT = COLUMN /* ................... OS ............................. */ OBJECT = COLUMN NAME = "REC_CDMS_MSG" DATA_TYPE = ASCII_INTEGER START_BYTE = 410 BYTES = 6 UNIT = "N/A" FORMAT = "I6" DESCRIPTION = "Counter for received CDMS messages" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TRANS_CDMS_MSG" DATA_TYPE = ASCII_INTEGER START_BYTE = 417 BYTES = 6 UNIT = "N/A" FORMAT = "I6" DESCRIPTION = "Counter for transmit CDMS messages" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "STAT_CDMS_MSG" DATA_TYPE = ASCII_INTEGER START_BYTE = 424 BYTES = 6 UNIT = "N/A" FORMAT = "I6" DESCRIPTION = "Counter for CDMS status messages" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "STORED_MSG" DATA_TYPE = ASCII_INTEGER START_BYTE = 431 BYTES = 6 UNIT = "N/A" FORMAT = "I6" DESCRIPTION = "Counter for stored messages (TCs)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "RERC_MSG" DATA_TYPE = ASCII_INTEGER START_BYTE = 438 BYTES = 6 UNIT = "N/A" FORMAT = "I6" DESCRIPTION = "Counter for RERC messages" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LAST_SSIF_ERROR" DATA_TYPE = ASCII_INTEGER START_BYTE = 445 BYTES = 6 UNIT = "N/A" FORMAT = "I6" DESCRIPTION = "Last received SSIF error code)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LOBT_HIGH" DATA_TYPE = CHARACTER START_BYTE = 453 BYTES = 4 UNIT = "N/A" DESCRIPTION = "LOBT, high in Hexadecimal Format" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LOBT_LOW" DATA_TYPE = CHARACTER START_BYTE = 460 BYTES = 4 UNIT = "N/A" DESCRIPTION = "LOBT, low in Hexadecimal Format" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "BRAM_POINTER" DATA_TYPE = ASCII_INTEGER START_BYTE = 466 BYTES = 6 UNIT = "N/A" FORMAT = "I6" DESCRIPTION = "BackupRAM pointer" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PHECOPY" DATA_TYPE = ASCII_INTEGER START_BYTE = 473 BYTES = 6 UNIT = "MILLIBAR" FORMAT = "I6" DESCRIPTION = "copy of Pressure HE" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MS_CYCLES" DATA_TYPE = ASCII_INTEGER START_BYTE = 480 BYTES = 6 UNIT = "N/A" FORMAT = "I6" DESCRIPTION = "MS cycles" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "GC_CYCLES" DATA_TYPE = ASCII_INTEGER START_BYTE = 487 BYTES = 6 UNIT = "N/A" FORMAT = "I6" DESCRIPTION = "GC cycles" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SYSSTATUS2" DATA_TYPE = CHARACTER START_BYTE = 495 BYTES = 4 UNIT = "N/A" DESCRIPTION = "System Status 2 (Hexadecimal Format) Single Shot Valve: b01 = armed, b11 = fired HK auto collection: 0 = disabled, 1 = enabled MM dump: 0 = idle, 1 = in progress MM auto dump: 0 = disabled, 1 = enabled" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SYSSTATUS1" DATA_TYPE = CHARACTER START_BYTE = 502 BYTES = 4 UNIT = "N/A" DESCRIPTION = "System Status 1 (Hexadecimal Format) Configuration valid: bxx1 = TPST, bx1x = MS, b1xx = GC Continue Flag (not supported) Waiting flag (not supported) System Mode: b000 = idle, b001 = GC, b010=MS, b011=GCMS, b100 = Self test Power Switch: bxxx1=pws1, bxx1x=pws2, bx1xx=pws3 (not used), b1xxx = pws4 Mass Memory: 0 = off, 1 = on EEPROM Timestamp: 0 = okay, 1 = mismatch TPST direction changed: 0 = false, 1 = true SD2 ready flag: 0 = false, 1 = true" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "ERROR_MSG" DATA_TYPE = ASCII_INTEGER START_BYTE = 508 BYTES = 6 UNIT = "N/A" FORMAT = "I6" DESCRIPTION = "Error Message" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TPST_LAST" DATA_TYPE = ASCII_INTEGER START_BYTE = 515 BYTES = 6 UNIT = "N/A" FORMAT = "I6" DESCRIPTION = "Last read position of TPST" END_OBJECT = COLUMN /* ------------------------------------------------------------------- */ /* Values used internally and added to the science data stream (42) */ /* -------------------------------------------------------------------- */ OBJECT = COLUMN NAME = "ALLOC_BRAM_SIZE" DATA_TYPE = CHARACTER START_BYTE = 523 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal format) Allocated BackupRAM size of Cosac inside CDMS memory 0x0000 <= x <= 0xffff" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CKECK_SC_PACKET" DATA_TYPE = CHARACTER START_BYTE = 530 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal format) Checksum of Science Data packet as received from CDMS 0x0000 <= x <= 0xffff" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "OFF_LEN_TC" DATA_TYPE = CHARACTER START_BYTE = 537 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal format) Offset & Length of stored TC, see CDMS SSpec; 0x0000 <= x <= 0xffff" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SCHED_SSIF_REQ" DATA_TYPE = CHARACTER START_BYTE = 544 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal format) Currently scheduled SSIF Request Code, see CDMS SSpec; 0x0000 <= x <= 0x0a" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LAST_CDMS_SSS" DATA_TYPE = CHARACTER START_BYTE = 551 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal format) last CDMS Service System Status, see CDMS SSpec; 0x0000 <= x <= 0xffff" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "LAST_CDMS_MODE" DATA_TYPE = CHARACTER START_BYTE = 558 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal format)last CDMS Mode (RMOD) CDMS Mode SSCLK Frequency Current AMST ID" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TRIGGER_WORD" DATA_TYPE = CHARACTER START_BYTE = 565 BYTES = 4 UNIT = "N/A" DESCRIPTION = " (Hexadecimal format) Trigger word Dest. Unit Trigger Word Field" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "ALLOC_SC_VOL" DATA_TYPE = CHARACTER START_BYTE = 572 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal format) Allocated Science Data Volume, see CDMS SSpec; 0x0000 <= x <= 0xffff" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "$MMFIRSTINIT" DATA_TYPE = CHARACTER START_BYTE = 579 BYTES = 5 UNIT = "N/A" DESCRIPTION = "First init. of Mass Memory needed Possible values : false true" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "$MMRDCNTHIGHMASS" DATA_TYPE = CHARACTER START_BYTE = 587 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal format) Memory read counter high address 0x0000 <= x <= 0xffff" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "$MMRDCNTLOWMASS" DATA_TYPE = CHARACTER START_BYTE = 594 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal format) Memory read counter low address, 0x0000 <= x <= 0xffff" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MMADRHMASS" DATA_TYPE = CHARACTER START_BYTE = 601 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal format) MMADRHMass Memory SW addr counter,high" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MMADRLMASS" DATA_TYPE = CHARACTER START_BYTE = 608 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal format) Memory SW addr counter, low" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MM$FLUSH" DATA_TYPE = CHARACTER START_BYTE = 615 BYTES = 5 UNIT = "N/A" DESCRIPTION = "Flag if MM flush is needed Possible values : false true" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "$RFR" DATA_TYPE = CHARACTER START_BYTE = 623 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal format) Frame read index 0x0000 <= x <= 0xffff" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "$WFR" DATA_TYPE = CHARACTER START_BYTE = 630 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal format) Frame write index 0x0000 <= x <= 0xffff" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "$PFR" DATA_TYPE = CHARACTER START_BYTE = 637 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal format) current Frame index 0x0000 <= x <= 0xffff" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "$RMMFR" DATA_TYPE = CHARACTER START_BYTE = 644 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal format) Mass Memory frame read index 0x0000 <= x <= 0xffff" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "$WMMFR" DATA_TYPE = CHARACTER START_BYTE = 651 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal format) Mass Memory frame write index 0x0000 <= x <= 0xffff" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "$PMMFR" DATA_TYPE = CHARACTER START_BYTE = 658 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal format) current Mass Memory frame index 0x0000 <= x <= 0xffff" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "$IDLECNT" DATA_TYPE = CHARACTER START_BYTE = 665 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal format) Idle task counter 0x0000 <= x <= 0xffff" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "$SD2STATUS" DATA_TYPE = CHARACTER START_BYTE = 672 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal format) Copy of SD2 carousel status, 0xf000 = SD2 Ready" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "$MMDUMP" DATA_TYPE = CHARACTER START_BYTE = 679 BYTES = 5 UNIT = "N/A" DESCRIPTION = "Mass Memory auto-dump Possible values : false true" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TDCMODE" DATA_TYPE = CHARACTER START_BYTE = 687 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal format) Mode in which the TDC is operated in" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "$DPUADR" DATA_TYPE = CHARACTER START_BYTE = 694 BYTES = 4 UNIT = "N/A" DESCRIPTION = "(Hexadecimal format) First faulty address of DPU memory, default : 0X0000" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "$EODATA" DATA_TYPE = CHARACTER START_BYTE = 701 BYTES = 5 UNIT = "N/A" DESCRIPTION = "Create OCPL when MM empty, Possible values : false true" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "$EOM" DATA_TYPE = CHARACTER START_BYTE = 709 BYTES = 5 UNIT = "N/A" DESCRIPTION = "End of measurement, Possible values : false true" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "$TDCSKIP" DATA_TYPE = CHARACTER START_BYTE = 717 BYTES = 5 UNIT = "N/A" DESCRIPTION = "TDC produced time-out, Possible values : false true" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "$GCSKIP" DATA_TYPE = CHARACTER START_BYTE = 725 BYTES = 5 UNIT = "N/A" DESCRIPTION = "GC produced time-out, Possible values : false true" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "GVSTAC.RESULT" DATA_TYPE = CHARACTER START_BYTE = 733 BYTES = 3 UNIT = "N/A" DESCRIPTION = "Result of last action, Possible values : OK NOK" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SER_SYS_STAT" DATA_TYPE = CHARACTER START_BYTE = 739 BYTES = 49 UNIT = "N/A" DESCRIPTION = "Copy of CDMS Service System Status ; see CDMS SSpec (String of 10 word in Hexadecimal format; each word separated by a space)" END_OBJECT = COLUMN