PDS_VERSION_ID = PDS3 RECORD_TYPE = UNDEFINED ^PDF_DOCUMENT = ("RADIOCALMVIC.PDF") ^ASCII_DOCUMENT = ("RADIOCALMVIC.ASC") ^PNG_DOCUMENT = {"RADIOCALMVIC_EQUATION1.PNG", "RADIOCALMVIC_EQUATION2.PNG", "RADIOCALMVIC_FIGURE1.PNG", "RADIOCALMVIC_FIGURE2.PNG", "RADIOCALMVIC_FIGURE3.PNG", "RADIOCALMVIC_FIGURE4.PNG", "RADIOCALMVIC_FIGURE5.PNG", "RADIOCALMVIC_FIGURE6.PNG", "RADIOCALMVIC_FIGURE7.PNG", "RADIOCALMVIC_TABLE1.PNG", "RADIOCALMVIC_TABLE2.PNG", "RADIOCALMVIC_TABLE3.PNG", "RADIOCALMVIC_TABLE4.PNG", "RADIOCALMVIC_TABLE5.PNG", "RADIOCALMVIC_TABLE6.PNG", "RADIOCALMVIC_TABLE7.PNG", "RADIOCALMVIC_TABLE8.PNG"} MISSION_NAME = "NEW HORIZONS" DATA_SET_ID = {"NH-J-MVIC-2-JUPITER-V2.0", "NH-J-MVIC-3-JUPITER-V2.0", "NH-X-MVIC-2-LAUNCH-V2.0", "NH-X-MVIC-3-LAUNCH-V2.0"} PRODUCER_INSTITUTION_NAME = "SOUTHWEST RESEARCH INSTITUTE" PRODUCT_CREATION_TIME = 2009-02-23T23:30:00 INSTRUMENT_NAME = "MULTISPECTRAL VISIBLE IMAGING CAMERA" INSTRUMENT_ID = "MVIC" INSTRUMENT_HOST_NAME = "NEW HORIZONS" OBJECT = PDF_DOCUMENT DOCUMENT_NAME = "MVIC Radiometric Calibration" PUBLICATION_DATE = 2007-10-17 DOCUMENT_TOPIC_TYPE = "CALIBRATION REPORT" INTERCHANGE_FORMAT = BINARY DOCUMENT_FORMAT = "ADOBE PDF" DESCRIPTION = "Using the MVIC filter functions, Beam Splitter reflectance, Aluminum mirror reflectance, and the product of quantum efficiency and filter function (product QE), calculate the final transmission (CHI) for each CCD array. CHI is the product of quantum efficiency, filter function, beam splitter reflectance, and the AL mirror reflectance cubed. To calculate the full response, we multiply the final transmission by a spectrum, both from observations of various solar system bodies and a calculated black body." END_OBJECT = PDF_DOCUMENT OBJECT = ASCII_DOCUMENT DOCUMENT_NAME = "MVIC Radiometric Calibration" PUBLICATION_DATE = 2007-10-17 DOCUMENT_TOPIC_TYPE = "CALIBRATION REPORT" INTERCHANGE_FORMAT = ASCII DOCUMENT_FORMAT = TEXT DESCRIPTION = "Using the MVIC filter functions, Beam Splitter reflectance, Aluminum mirror reflectance, and the product of quantum efficiency and filter function (product QE), calculate the final transmission (CHI) for each CCD array. CHI is the product of quantum efficiency, filter function, beam splitter reflectance, and the AL mirror reflectance cubed. To calculate the full response, we multiply the final transmission by a spectrum, both from observations of various solar system bodies and a calculated black body." END_OBJECT = ASCII_DOCUMENT OBJECT = PNG_DOCUMENT DOCUMENT_NAME = "MVIC Radiometric Calibration figures" PUBLICATION_DATE = 2007-10-17 DOCUMENT_TOPIC_TYPE = "CALIBRATION REPORT" INTERCHANGE_FORMAT = BINARY DOCUMENT_FORMAT = PNG DESCRIPTION = "Figures for the ASCII document having the following description: Using the MVIC filter functions, Beam Splitter reflectance, Aluminum mirror reflectance, and the product of quantum efficiency and filter function (product QE), calculate the final transmission (CHI) for each CCD array. CHI is the product of quantum efficiency, filter function, beam splitter reflectance, and the AL mirror reflectance cubed. To calculate the full response, we multiply the final transmission by a spectrum, both from observations of various solar system bodies and a calculated black body." END_OBJECT = PNG_DOCUMENT END