DIF-C-HRII-3/4-EPOXI-HARTLEY2-V3.0 Review Result: Certified. Symbol Key: o = Lien open x = Lien resolved or closed ! = Lien rejected or not applicable + = Comments (by SMcLaughlin unless otherwise indicated) Catalog ======= ! In the dataset.cat file description, please add full citations to the Calibration papers (i.e., as footnotes in the text in addition to the REFERENCE objects that also exist). + Rejected by PI and archive lead. The correct and full citations are already in ref.cat. x In dataset.cat. the CITATION_DESC year must be '2014' since this is when the data were reviewed and released to the public. + Done. x Please note in the dataset.cat Confidence Level Note that transient anomalous pixels may be present in the data. + Done. ! In dataset.cat, the description of the east flip for lookback images is incorrect. (In the paragraph beginning, "Using this convention for Tempel 1 approach images...".) See Jianyang's slide 17 for the geometry and correct orientation. + Rejected. This lien applies for the HRII Tempel1 dataset; copied it there. Documents ========= x Ensure these data sets have the latest versions of these document files: day_of_year_calendar.lbl epoxi_cal_pipeline_summ.lbl epoxi_sis.lbl instruments_hampton.lbl pdsdd_epoxi.lbl quaternion_desc.lbl + Done. x In epoxi_sis.pdf: x This document says labels for HRIV, MRI, and ITS level 3/4 data, PDS keyword PROCESSING_HISTORY_TEXT contain FLAT_PRO= FLATCONS= FLATTEMP= CALWINDW= CALWINPY= but the sample labels in the SIS's 4.4.4.1 and 4.4.4.2 do not. x p. 27: "DIF-L-HRII-3_4-EPOXI-LUNAR-CALS-V1.0" should have a / not a _ i.e. "DIF-L-HRII-3/4-EPOXI-LUNAR-CALS-V1.0" x epoxy_sis.pdf pages 47-9 the figures are misaligned with the text. This needs to be corrected in every copy of the document in all data sets. + Done, except for the item about PROCESSING_HISTORY_TEXT. That PDS keyword will contain different processing keywords because the calibration pipeline performs different steps for the VIS HRIV, MRI, and ITS CCDs and the IR spectrometer. For example, the FITS header keywords FLAT_PRO, FLATCONS, FLATTEMP, CALWINDW, & CALWINPY only apply to IR calibration, so those values are never included in PROCESSING_HISTORY_TEXT. However, we noted this difference in the description of PROCESSING_HISTORY_TEXT in the SIS. For last item, had to print the Word file as a Postscript to force alignment of figure pieces with text, then distilled the Postscript to PDF/A. x There are summary files with names like hriv_3_4_epoxi_garrad.pdf. In at least some of these labels in some data sets, the Julian Date field is described as being in the form YYYYMMDD. This needs to be fixed if it applies to this data set. + Done. x In places that describe the file naming convention, there needs to be a clear indication of which time (beginning, middle, end) is used for creating the file name. + Not applicable. Mid-obs is used in the filenames and for grouping products into DOY directories, and this is already called out in the EPOXI SIS and dataset.cat files! CALIB/ ====== x Unlike other HRII calibrated data, there are no actual dark frames included nor is the sunspec directory included. If these are relevant to these data, please add them. + Added the sunspec directory to all HRII calibrated for this peer review; the Tempel1 dataset already had it. All HRII datasets already have the dark model frames needed by the pipeline. See /drkmodel/. x In lindn/*lbl: AXIS_NAME = ("LINE_SAMPLES", "LINES", "PER_PIXEL_LINEARITY_COEFFS") is legal, but "SAMPLE" and "LINE" (singular) are much more common. + Done.